Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet 0.44 0.40 0.40 0.44 0.40 0.41 0.63 0.63 0.41 0.63 0.13 0.10 0.10 0.13 0.10 0.20 0.14 0.14 0.20 0.14 VK332 0.47 0.41 0.41 0.47 0.41 0.85 0.65 0.65 0.85 0.65 0.47 0.38 0.38 0.47 0.38 0.76 0.41 0.41 0.76 0.41 0.44 0.27 0.27 0.44 0.27 0.26 0.24 0.24 0.26 0.24 0.13 0.10 0.10 0.13 0.10 0.19 0.15 0.15 0.19 0.15 0.47 0.39 0.39
P FR (2) 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 FP Note 2) W/ end lock is not available in Series MXQ6.
Microspeed Cylinder: Double Acting/Single Rod Series CQ2X 32, 40, 50, 63, 80, 100 Dimensions and auto switch details are equivalent to those of the standard double acting single rod cylinder. How to Order B 40 30 D CQ2X Without auto switch With auto switch CDQ2X A73 B 40 30 D Number of auto switches With auto switch (with built-in magnet) Auto switch type 2 pcs. 1 pc. "n" pcs.
Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St.
4 Body B O-ring Electroless nickel plated Brass NBR e !5 Body B O-ring Electroless nickel plated Brass NBR r !6 Needle Spacer Electroless nickel plated Brass POM (2) t !7 Seat ring Gasket Electroless nickel plated Brass NBR, Stainless steel y !8 Spring Retaining ring for hole type C Steel wire Tool steel u !
Dimensions XMH series / Angled Valve C D L1 L2 A Fn Fc C (Fc) (CF Flange) (KF Flange) H J H B G A Unit:mm Table 5 Model A B C D Fn Fc G H J P.C.D L1 L2 XMH-16 40 100.5 38 1 30 34 17 35 18 P.C.D 27 6x4.4 XMH-25 50 114 48 1 40 26 41 21.5 XMH-40 65 162.5 66 2 55 70 41 57 30 P.C.D 58.7 6x6.6 XMH-50 70 179.5 79 2 75 52 70 35 XYH series / Straight Valve D G C C B H Fn J (KF Flange) 45 Unit: mm
pressure: 0.4 MPa 100 90 100 90 ZQ Vacuum pressure (kPa) Vacuum pressure (kPa) 80 80 70 70 ZF 60 60 50 50 ZP 40 40 30 30 ZCU 20 20 10 10 AMJ 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate (/min(ANR)) Suction flow rate (/min(ANR)) Misc.
View A PFW31(-M) PFW3-B DIN rail type 8-M3 3 x 7.2 (= 21.6) 36 2-3.4 6.4 15 1 2 3 4 6.5 26 FLOW SWITCH SMC 35.5 30 56 (4.5) 44 UNIT RESET SET 5 6 7 8 29 38 15.2 26
200 300 400 500 1000 1500 2000 3300 4000 4000 5700 7000 HAW2 5 HAW7 5 HAW22 17 HAW37 25 Maintenance 7000 8600 10 34.5 36 37 40 44 46 38 40 42.5 43 49 54 36 Caution HAW55 1.
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4
Rc 1/4 108 Head end cylinder port Rc 1/4 Dustproof cover Rod end cylinder port (Manual lock release) D (Stroke) Rc 1/8 Unlocking port IN OUT (125) (102) C B A Rc 1 DRAIN 195 (270) Dimensions (mm) A B C D Model Bore size (Nominal size B) FN111 FN112 610 (730) (844) 20 Rc 1 860 (1000) (1134) 40 8 Series FN1 Options Reservoir Dust removal filter 108 32 0 315 45 P.C.D.220 70 70 90 270 (80) 50
Recommended cables are specified in the accessories section, on page 40. -39No.EX-OMP0013-E Accessories Fieldbus interface connector (1) Cable with communication connector (SPEEDCON) Part number: PCA-1446566 Item Specifications Pin No.
32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.
Replace the switch with a new one if the problem is not solved. switch -18- Basic Construction Fig.5 MWPU63-40-5-** Assembly drawing Fig.6 MWPU63-40-5-** Assembly drawing Fig.7 MWPQ125-40-5-** Assembly drawing Fig.8 MWPQ125-40-5-** Assembly drawing -19- Fig.5 -20- Fig.6 -21- Fig.7 -22- Fig.8 -23- Revision history Initial Release SZ Edition A *Document report P.13 TP Edition B *Document report
IODD file 1 D-MP025A/B/C SMC-D-MP025-ymmdd-IODD1.1 2 D-MP050A/B/C SMC-D-MP050-ymmdd-IODD1.1 3 D-MP100A/B/C SMC-D-MP100-ymmdd-IODD1.1 4 D-MP200A/B/C SMC-D-MP200-ymmdd-IODD1.1 : "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.
High Suction Vacuum Work 1 Work 2 Work n Max.A ON point OFF point Min.B Not adsorption Work 1 Work 2 Work n Atmosphere A B 4 A B 4 = A ON point Max.A: Maximum pressure value when work piece is vacuumed. Min.B : Maximum pressure value when work piece is not vacuumed.
4 5 6 7 8 9 10 L1 28 44 60 76 92 108 124 140 156 172 L2 40 56 72 88 104 120 136 152 168 184 L3 50 72 88 104 120 136 168 168 184 200 EXHAUST ADAPTOR LOCATION B .Both Ends FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOG REFERENCE N400
Part number Dimensions Filtration accuracy (m) Element symbol
P_1 = A-(A-B)/4 A = Maximum pressure value H_1 = | (A-B)/2| B = Minimum pressure value To clear the stored auto-preset settings, press the and buttons simultaneously for 1 second or longer. 28 - NO. ZQ-OM01501 [F 6] Fine adjustment of display value This function is used to manually perform fine adjustment of the displayed pressure. It is adjustable within the range 5% R.D.