mA ) PNP1.5 V (80 mA ) 1 s 1F.S. 2F.S. 5F.S. 0 3 (3 digits) 50 ms 0.1 L/pulse 0.5 L/pulse 1 L/pulse 2 L/pulse 5 L/pulse 5F.S. 3 7 OUT1ON OUT2ON DC1224 V10 () 150 mA 160 mA 170 mA -35No.PF-OMO0007CN PF2A710 PF2A750 PF2A711 PF2A721 PF2A751 IP65 050 -2585 () 3585R.H.() 3F.S.(1535 )5F.S.(050 ) AC1000 V1 50 M(DC500 V ) CERoHS (RcNPTG) 1/81/4 3/8 1/2 ADCNBRSUSPBTPtlrFeNiOFC 250
min9.5 ) 290(7 s) 390(7 s) -67No.PF-OMN0011CN-C 0100 1 / -10110 1 3F.S. 7 s 2 5F.S. 1090 2 (ZS-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521 30 250
Approx. 1 second M3 x 8 L Water proof seal (accesorys) Measurement mode 4 L/min 40 L/min 100 L/min 16 L/min 250 L/min Panel Be sure to select the correct sensor to be connected. Caution *: The panel mount adapter can be rotated through 90 degrees for mounting. *: The panel mount adapter should be fixed firmly with screws. Otherwise, fluids such as water may enter.
Installation distance and Discharge time (Discharge time of 1000V100V) Applicable models: IZT43(-L) 1) Without air purge 5.0 4.5 4.0 Discharge time [s] 3.5 s 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 50 100 150 200 250 300 Installation distance [mm] mm 2) High speed static neutralization cartridge with air purge 10.0 9.0 8.0 250L/min 20L/min 7.0 Discharge time [s] s 6.0 180L/min 5.0 60L/min 4.0 3.0 2.0
Setting of response delay time Setting range: 0 to 250 ms to Setting/Checking: Communication range (simple communication protocol) 27. Press the [SEL] key once. T Setting screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 28. Set communication range (simple communication protocol) with [] key or [] key, and press [SEL] key to enter.
fluid temperature monitoring function / Changing of electric conductivity increase alarm*1 / WRN CTRL FLT 50 HITEM DIHI ALARM dDI INP2 ALARM DI CTRL PUMPP TEMP OUT TYPE / / Setting of electric conductivity increase alarm*1 Contact input signal 2 Delay timer / Electric conductivity set value* 1 450 Circulating fluid temperature range rise, the monitoring method of drop alarm RNST / 0 250
fluid temperature monitoring function / Changing of electric conductivity increase alarm*2 / WRN CTRL FLT 10 HITEM DIHI ALARM dDI INP2 ALARM DI CTRL PUMPP TEMP OUT LOTEMP / / Setting of electric conductivity increase alarm*2 Contact input signal 2 Delay timer / Electric conductivity set value* 2 450 Circulating fluid temperature range rise, the monitoring method of drop alarm RNST / 0 250
communication protocol Item Specification Standard Select from EIA RS-485/RS-232C Communication speed Select from 1200bps/2400bps/4800bps/9600bps/19200bps Databit length Select from 7bit/8bit Stopbit length Select from 1bit2bit Parity Select from without parity ,odd number ,even number Letter code ASCII mode Slave address set range Select from 1 to 99 Response delay time setting Select from 0 to 250
communication protocol Item Specification Standard Select from EIA RS-485/RS-232C Communication speed Select from 1200bps/2400bps/4800bps/9600bps/19200bps Databit length Select from 7bit/8bit Stopbit length Select from 1bit2bit Parity Select from without parity ,odd number ,even number Letter code ASCII mode Slave address set range Select from 1 to 99 Response delay time setting Select from 0 to 250
After cleaning the filter, return it to the product. 0 to 250 ms 0ms times of If the trouble cannot be solved even after restart, temperature sensor need to be replaced. 5 7 0.10 to 10.00 times. AL2 Temperature sensor breaks. P1 set Set with [] or [] key value If the trouble cannot be solved even after restart, temperature sensor need to be replaced.
SV C 0 to 250 ms 0ms 4 Filter clogged Clean the filter. Set with [] or [] key The fan breaks Check the fan operation. If the fan breaks, need to be replaced. Screws for maintenance 7 Outline Dimensions (mm) Heating The EEPROM of Controller is broken due to high-level electric noise. If the trouble cannot be solved even after restart, contoller need to be replaced.
SUS304 SUS316L ( SUS304) ( A6063) C D C E E (KF ) Fn J H B A G A mm A B C D E Fn G H J XLC-16 40 110 38 1 30 17 40 26 XLC-25 50 120 48 1 12 40 26 39 27.5 XLC-40 65 171 66 2 11 55 41 63 36 9 XL-OMV0002 4-2.162580,100,160 C E D C E E (KF ) (K ) Fn Fd J K H B A G A mm A B C D E Fn Fd G H J K XLC-50 70 183 80 31 10.5 75 52 77 29 10.5 XLC-63 88 209 100 39 11 87 95 70 76.5 36 9 XLC-80 90 250
Dimensions E C D E E L (Width across flats) M (Width across flats) M8 (KF Flange) (K Flange) Fn Fd C Detail of (a) (a) M Rc1/8 J H K B A G A Model A B C D E Fn Fd XLGR-80*-1* 90 250 117 45.5 38.5 114 110 XLGR-100*-1* 108 270.5 154 55 38.5 130 102 XLGR-160*-1* 138 339 200 65 38.5 180 153 Model G H J K L M XLGR-80*-1* 83 105 44 9 13 4 XLGR-100*-1* 102 92 58 9 13 4 XLGR-160*-1* 153 124 62 12.5
Fn Fc G H J P.C.D L1 L2 XMC-16 40 110 38 1 30 34 17 40 26 P.C.D 27 6x4.4 XMC-25 50 120 48 1 40 26 39 28 XMC-40 65 171 66 2 55 70 41 63 36 P.C.D. 58.7 6x6.6 C D L1 L2 Fn Fd Fc C (Fc) (KF Flange) (K Flange) (CF Flange) H J K B A G A Unit:mm Model A B C D Fn Fc Fd G H J K P.C.D L1 L2 XMC-50 70 183 80 31 75 52 77 29 10.5 XMC-63 88 209 100 39 87 114 95 70 76.5 36 9 P.C.D 92.1 8x8.4 XMC-80 90 250
Port size(Rc) 3/8,1/2,3/4,1 Max. operating pressure (MPa) 1.0 Max. operating temperature (oC) 80 (below boiling point) Number of elements 1 Element size(mm) Note 1) 125 250 500 Differential pressure for element replacement (MPa) 0.1 Cover SUS316 Case SUS316 Materials Gasket/O-ring PTFE Note 2) Seal PTFE Weight (kg) Note 3) 2.6 3.2 4.3 Internal capacity (L) 1.0 1.8 3.3 Note 1) The element
Table 6-9 Rating Soldering terminal Rated voltage Resistance load 250 VAC 5A (3) Other performance Table 6-10 Other specifications Item Specifications Insulation resistance 100 M or more (Measured by 500 VDC, insulation resistance tester. ) Contact resistance 30m or less Between terminals with the same pole AC1000V 50/60Hz 1min Between charged metal part and ground AC1500V 50/60Hz 1min Withstand
Description Decimal Common Format "Data-INT" "Data-SINT" Input MIN. 1 word MIN. 2 byte MAX. 250 words MAX. 500 byte Output MIN. 1 word MIN. 2 byte MAX. 248 words MAX. 496 byte Configuration 0 : Select the setting according to the system configuration (number of paired remote). : When the EXA1 connects to the PLC made by Rockwell Automation, Inc., the maximum size of input and output are
Setting of response delay time Setting range: 0 to 250 ms to Setting/Checking: Communication range (simple communication protocol) 27. Press the [SEL] key once. Setting screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 28. Set communication range (simple communication protocol) with [] key or [] key, and press [SEL] key to enter.
This person should also continuously review all specifications of the product referring to its latest catalogue information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 100 0.05 0.09 0.15 0.24 0.39 0.64 1.00 125 0.07 0.11 0.18 0.29 0.47 0.76 1.20 150 0.08 0.13 0.21 0.34 0.54 0.89 1.30 200 0.10 0.17 0.28 0.44 0.70 1.10 1.70 250
(g) Size 1 2 3 7 Basic Type 75 105 150 250 High precision Type 80 115 165 265 * Values excluding the weight of auto switch Effective torque 0.8 7 Effective torque (Nm) 0.6 3 0.4 2 0.2 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Operating pressure (MPa) 19 - Internal construction and parts MSQ1 to 7 20 11 18 12 17 23 21 2 24 7 1 15 14 13 6 14 15 24 5 10 9 16 22 8 4 3 19 24 O ring 4 23 Hexagon socket set