) N01 NPT1/8 (M5) A1 A C4H 4mm5/32 inch C6H 6mm A2 B NH7 1/4 inch N7H A3 C C4L 4mm5/32 inch C6L 6mm B N7L 1/4 inch D + N NPN1 P PNP1 A NPN2 B PNP2 C NPN1+ D NPN1+ E PNP1+ F PNP1+ 1 L (2 m) 1 (2 m 1 G 1 M SI2 P (psi)1 1NP3 4 1 2kPaMPa -8No.PS-OML0002CN-G / A ZS-38-A1 (M35 L 2 ) B ZS-38-A2 (M35 L 2 ) C ZS-38-A3 (M35 L 2 ) ZS-27-C (M38 L 2 ) + ZS-27-D (M38 L 2 ) ZS-38-3L 3
AN103-01 AN210-02 1) VEX1-9-1P VEX4-2A-P VEX1-11-2 VEX4-4 DXT152-14-1A NXT013-3 VO307K-1 2) 3) VEX322 VEX342 Rc A 1/8 1/4 F G VVEX2 VVEX4 B 1/4 3/8 N NPT ( ) VEX1-17 VEX4-5 C 1/2 T NPTF 11 No.VEX-OMY0001 (2) () 3 2(A) 23(P2) 12(P1) a,b 12(P1),23(P2) (2) a 12(P1) 1(P)2(A)3 3(R) 3(R) b 23(P2) 2(A) 2(A)3(R)1 1(P) 1(P) 12(P1) 1 2 3 23(P2) 4 5 6 7 8 POM 9 -12No.VEX-OMY0001
Power consumption P: 20 [kW] Q = P = 20 [kW] Cooling capacity = Considering a safety factor of 20%, 20 [kW] x 1.2 = V: Power supply voltage P 24 [kW] Power consumption e Derive the heat generation amount from the output. Output (shaft power, etc.) W: 13 [kW] w Derive the heat generation amount from the power supply output.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: ø6 One-touch Fitting, Elbow Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Note 1) To change the port size of the 1(P), 3/5(E) ports into the Fitting Replacement By replacing a valves fitting assembly, it is possible to change the port size of the 4(A), 2(B), 1(P), and 3/5(E) ports. When replacing it, pull out the fitting assembly after removing the clip with a flat blade screw driver, etc.
Supply pressure (MPa) Flow rate (l/min (ANR)) 13-4-27 8 Series ZMA Dimensions 111 S: Vacuum pressure switch trimmer Pilot valve for vacuum pressure T: Release period adjustment trimmer Pilot valve for vacuum release M5 x 0.8 through (P, E port) Release flow adjustment screw 3-Rc 1/8 SUP.
Appearance Terminal block For wiring, please refer to P.2-5 10,11Remote control 12,13Operation 14,15Failure L1,L2,L3: Power supply PE: Ground 15 14 13 12 11 10 PE L3 L2 L1 Customer Connection Side Customer Connection Side Terminal connecting screw: M3 Terminal connecting screw: M5 Crimped terminal width: 6.5mm or less Crimped terminal width: 13mm or less Applicable electric wire: 8mm 2
Terminal block For wiring, please refer to P.2-5 10,11Remote control 12,13Operation 14,15Failure R,S,T: Power supply PE: Ground 15 14 13 12 11 10 R S T To the users machine To the users machine Terminal connecting screw: M3 Terminal connecting screw: M5 Crimped terminal width: 6.5mm or less Crimped terminal width: 13mm or less Applicable electric wire: 8mm 2 or more Applicable electric wire
When the product is mounted using the bracket, fix with M5 screws (2 pcs.) or equivalent. The Bracket thickness is approx. 1.6 mm.
OFF state { A R1 (Exhaust air) P B (Supply air) F1 < F2 condition: See figure q. ON state { { Immediately after turning on F1 > F2: See figure e.