for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Dd9 d L m t CJ2 l Applicable bore (mm) Applicable snap ring Part no.
MQR Symbol O.D. x I.D. 0425 4 x 2.5 0604 6 x 4 0805 8 x 5 1065 10 x 6.5 1208 12 x 8 Symbol Number of cores X169 2 cores X170 3 cores X171 4 cores X172 5 cores T T IDK Tube length per roll [m] Color*1 Symbol Length A 1 B 2 C 3 D 4 E 5 F 10 G 20 Symbol Color Symbol Color 1 Black 5 Yellow 2 White 6 Green 3 Red 7 Translucent*2 4 Blue 8 Yellow brown Yellow Blue Red White Black Inside of the roll
Silver (S1) MS Solid yellow (Y1) Clear yellow (Y2) KKA Neon yellow (Y3) KP Clear orange (YR1) Neon orange (YR2) LQ Nominal size (inch) 1 4 " 3 16" 1 8 " 3 8 " 1 2 " 5 32" 5 16" MQR Nominal size (mm) T T 3.2 IDK Fluid Air/Water 20C 0.8 Max. operating pressure (MPa) Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually.
Function: 3 (3 Position Closed Center), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: T
Function: 2 (2 Position Double), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports 3), Thread: T (NPTF)
Model: 31, Orifice: 3 (3mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: T (with Conduit Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: T (Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil), Port Size: 06 [3/4 (20A)], Thread: T (NPTF), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Bracket: B (Bracket)
E: Emitter C: Collector B: Base B: Base E: Emitter C: Collector Fig. (1) NPN type Fig. (2) PNP type 16-13-4 12 Glossary of Terms U Reversed output mode Refer to Hysteresis mode and Window comparator mode in Technical Information on page 16-13-8. Unit conversion Refer to Technical Information on page 16-13-13. URJ Abbreviation of Union Ring Joint and means VCR fitting.
IN Ex. 2) When using contact b only LAMP LIGHTS WHEN PRESSURE RISES. N.C. C. CR Caution Component Parts 1. In the case of using a switch with indicator light, wire the indicator light per the following: 2. Please put the enclosed seal of LAMP LIGHTS WHEN PRESSURE RISES. or LAMP GOES OUT WHEN PRESSURE RISES. on the equipment where it is easy to see.
Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 7 (Screw Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch)
Override: Non-locking Push Type, A,B Port Size: None, A,B Port Thread Type: Rc (or None), Mounting Option: K [Round head combination screw (Falling-out prevention type)], Wiring Specification: WO (w/o M12 Connector Cable), Port Location: Side Ported, Sub-plate Thread: T (NPTF)
The pressure in the pilot chamber r increases and operates on the upper surface of the diaphragm t. As a result, the air supply valve y linked to the diaphragm t opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u.
Material: T (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Seal), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size: 04 (1/2 Rc), Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 50 μm, Element Seal Material: T (Fluororesin)
Window comparator mode Bracket [F_2] Input the Set value of instantaneous output (Auto-preset) 34 mm Rc(NPT)1/4 12 to 14 Nm Selection of switch operation (OUT1) [1_n] Reverse output PF2W720(T) : This drawing is the model of PF2A710/750. 22 to 24 Nm Selection of switch operation (OUT2) [2_n] Reverse output Rc(NPT)3/8 PF2W740(T) ( ) Hysteresis Set point 2 Set point 1 Item Description Selection
Description AQ2000 AQ3000 AQ5000 AQ1500 AQ1510 Valve 30093 NBR 30073 30053 30063 30083 r O-ring 9 x 7 x 1 JIS B 2401P-7 NBR CA40-1601 CA50-1602 30066 t Dimensions AQ1500/1510 AQ2000/3000/5000 3-port size (Mounting hole) 3-port size L1 L2 L3 L4 L5 L6 L7 L8 L9 D L1 L2 L3 L4 Model Port size AQ2000 Model Port size 1 8 1 4 M5 x 0.8 AQ1500 23 20 14 3 12.5 12 15 5.5 6.5 3.1 45 40 10 45 , 3 8 1 4
AS ASP ASN AQ ASV Dimensions AK Universal type Weight (g) T H1 H2 D1 D2 D3 L1 L2 L3 L4 L5 A M1 Max. Min. Max. Min.
The parameters which can be set up are the following : Set-point activation temperature of the hot-gas solenoid valve (fix hysteresis t equal to 1.5 K). TON activation time of the condensate drain solenoid valve. TOFF pause time between two consecutive activation of the condensate drain solenoid valve.