SMC Corporation of America
Elite Part Number Search
Search Results "RZQD40TN-300-210-M9PL"

Made to Order How to Order 2 1 F 06 200 AS S Lubricant: Vaseline -X12 Example) AS2002FS-04-X12 Made to Order Body size Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Applicable tubing O.D.1 Example) AS2002FS-04-X21 * Not particle-free Metric size Inch size 23 3.22 04 4 06 6 08

TMH ASD AS Maximum return speed (mm/s) 100 200 300 Speed Controller Cylinder Solenoid valve Tubing Silencer AS-FE 6 ASD230FG CJ2 SYJ500 TU0604 1 m AN11001 KE 10 16 Cylinder size AS-FG AS-FG 20 ASD330FG CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 AS-FP 32 Values at 0.5 MPa and 20C.

To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.

100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.

Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40

Bore size CJ2 series Pressure 0.5 MPa Load ratio 50% Stroke 60 mm CM2 series Pressure 0.5 MPa Load ratio 50% Stroke 300 mm CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] 6 10 16 125 140 160 180 200 250 20 25 32 40 40 50 63 80 100 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward

Please contact SMC to check if the valve can be used in the application by providing the relevant fluid circuit. 223 VXS Series For Steam Dimensions/Body Material: C37, Stainless Steel Grommet Conduit terminal 34 D Q2 S2 F F Q 300 D 40 (42) 32 25 a h e Built-in full-wave rectifier type T R E (With surge voltage suppressor) C R E d g J C G1/2 f j J 2 x M depth 5 H B1 B 2 x M depth 5 H B1

0 CE-compliant u Electrical entry y Rated voltage i Light/surge voltage suppressor CE-compliant 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC Nil Q CE-compliant Nil None S With surge voltage suppressor Z With light/surge voltage suppressor G Grommet (Lead wire length 300 mm) H Grommet (Lead wire length 600 mm) L L type plug connector

Thus, from the formula on the front matter 9, the adsorption response time is as follows: T = (V x 60)/Q = (0.0031 x 60)/1.7 = 0.109 seconds = 109 msec It is possible to confirm that the calculation result satisfies the required specification of 300 msec. Front matter 15 Model Selection 8 Data #Selection Graph Selection Graph (2) Piping Capacity by Tube I.D.

RSH20, 32 Graphq Graphw 1.0 RSH32 RSH32 RSH32 Bore size 50, 63, 80/ m =0 Bore size 50, 63, 80/ m =0.1 RSH20 RSH20 RSH20 0.9 Operating pressure : P (MPa) 1300 1300 0.8 80 0.7 1200 1200 0.6 1100 1100 0.5 1000 1000 0.4 900 900 0.3 63 80 800 800 0.2 50 Weight : W (kg) Weight : W (kg) 700 700 0.1 600 600 100 200 300 400 500 0 63 500 500 Lateral load: W (N) 50 400 400 RSH50, 63, 80 300 300 1.0

To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.

Solenoid valve ( ): Effective area [mm2] : Metal : Metal seal Speed controller Composed effective area (mm2) E 64.8 to 67 D 36 to 45 VQ4000 (36.0) VQ4000 (39.6) VFR3000 (41.4) VFS3000 (36.0) G 180 to 300 VFR6000 (191) VFS6000 (180) VP70 (300) F 102.6 to 120 2 Standard type 1 With One-touch fittings C 16.2 to 21.6 VQ2000 (16.2) SY7000 (21.6) SX7000 (21.6) Elbow type 1-A Refer to System

Lateral load Operating pressure: 1 MPa 1000 200 300 500 Stroke Eccentric distance 100 100 Load weight (kg) 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 Allowable lateral load (N) 50 40 63 1 32 25 20 50 40 10 32 0.1 25 10 100 200 300 500 1000 Maximum piston

Bore sizes: 10, 15, 20, 25, 32, 40 mm; Stroke lengths: 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 1000 mm (15 bore), 1500 mm (20 bore), 2000 mm (25, 32 & 40 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.

Bore sizes: 25, 32, 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke lengths: 4000 mm (25 & 32 bore), 5000 mm (40 bore), 6000 mm (50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.

Bore sizes: 10, 15, 20, 25, 32 mm; Stroke lengths: 150, 200, 300, 400, 500, 600, 800, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1000 mm (20 bore), 1200 mm (25 bore), 1500 mm (32 bore); Minimum operating pressure: 0.2 MPa (29 psi); Speed: 70 ~ 300 mm/sec.