Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00025, Torque(N⋅m): 0.3, Operating Pressure
Oscillation Angle A: 360°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00025, Torque(N⋅m): 0.3, Operating Pressure Range(MPa
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00039, Torque(N⋅m): 0.75, Operating Pressure Range
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00039, Torque(N⋅m): 0.75, Operating Pressure
Oscillation Angle A: 360°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00039, Torque(N⋅m): 0.75, Operating Pressure Range(
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00025, Torque(N⋅m): 0.3, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00025, Torque(N⋅m): 0.3, Operating Pressure
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00039, Torque(N⋅m): 0.75, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Valves: Not Provided, Allowable Kinetic Energy(J): 0.00039, Torque(N⋅m): 0.75, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Valves: Provided, Allowable Kinetic Energy(J): 0.025, Torque(N⋅m): 1.8, Operating Pressure
Oscillation Angle A: 360°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Valves: Provided, Allowable Kinetic Energy(J): 0.025, Torque(N⋅m): 1.8, Operating Pressure
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Valves: Provided, Allowable Kinetic Energy(J): 0.081, Torque(N⋅m): 5.3, Operating Pressure
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Valves: Provided, Allowable Kinetic Energy(J): 0.081, Torque(N⋅m): 5.3, Operating Pressure
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available
Pressure sensing for air and liquid non-corrosive to 630 and 304 SST; Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc with M5 female; Panel mounting adapter available
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available
Pressure sensing for air and liquid non-corrosive to 630 and 304 SST; Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc with M5 female; Panel mounting adapter available
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., HIGH PRECISION DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 30 lb