4 IW 2 x 6.6 2 52 10 1301 AW 137 62 31 21 5 IL1 SIG OUT IN1 OUT1 SIG 2 IL2 IL2 IN2 OUT2 IT OUT 5 x Rc1/4 CP 60 IS IL220 VFN 14.5 INT Panel fitting dimension 2 x 6.6 45 58 Panel 35 Max. 4 2 18 57 10 130 2 OUT IN1 SIG 30 15 4 x Rc1/4 IN2 60 173
Verify the specifications before use. 5 Branch port B (COM B) 4 (Input: Max. 32 points/Output: Max. 32 points per branch) Number of branches Connect the SI unit (with manifold valves) or input unit using a branch cable.
Prevent the stoppage of rotating parts (pins, etc.) by applying grease. 10)Do not use the product until you have verified that the equipment can operate properly.
Rotary Clamp Cylinder: Standard 12, 16, 20, 25, 32, 40, 50, 63 MK Series How to Order MK 10 R 20 B N Z M9BW Rotary clamp cylinder Made to Order (Refer to page 390 for details.) Mounting bracket Auto switch type Mounting Symbol Nil S Through-hole/Both ends tapped common (Basic) 2 pcs. B 1 pc.
To directly thread in the cylinder, use durable fittings (Stainless steel square nipples etc,) instead of ductile iron fittings (JIS B 2301) or steel pipe fittings (JIS B 2302). When VNA is installed away from the cylinder, use a high-pressure rubber hose (JIS B 6349) instead of steel pipe, when possible. 2. Air bleeding Series VNA valves have no air bleeding port.
To mount ghl angle lype, be cedain 10 check that no possible ntefence occurs.
3 Component Parts No. 1 2 3 4 5 6 7 8 9 Description Description Material Aluminum die-cast Aluminum die-cast Rolled steel Aluminum alloy Brass Aluminum alloy Aluminum alloy Aluminum alloy Brass Material Stainless steel H-NBR Stainless steel Note Note Urban gray Urban white Nickel plated No. 10 11 12 13 14 15 16 17 18 Cover Body Plate Spool valve Orifice Valve seat Valve guide B Valve guide
AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series
(kg) Model FH150-02 FH150-03 FH150-04 1/4 80 168.5 197.5 259.5 50 15 25 7 6.5 0.7 3/8 1/2 524
Description Material ARM1000 ARM2000 134819-30#1 13615 13614 KA00347 16.5 x 13.5 x 1.5 KA00476 JIS B 2401 P7 (Initial setting) Inlet pressure: 0.7 MPa Outlet pressure: 0.2 MPa Flow rate: 10 L/min (ANR) 7 8 9 13626-30#1 13625 13624 KA00361 23 x 20 x 1.5 KA00087 JIS B 2401 P8 Valve Valve spring Valve guide Brass, HNBR Stainless steel Polyacetal 10 O-ring NBR Initial set point 11 O-ring NBR
8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
10 8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 13 16 19 20 22 25 108 155 221 1/4, 3/8 3/8, 1/2 1/2, 3/4 3 Series AMP Model Selection Selection Caution Caution 1.
Handling Precautions . 10 5. Names and functions of parts . 10 6. How to use . 11 7. Specification and how to order . 12 8. Discharge capability . 14 9. Troubleshooting . 16 10. Outer dimensions. 18 2 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Types S, Z 24 VDC: 7 to +10 %, 12 VDC: 4 to +10 % Type T 24 VDC: 8 to +10 %, 12 VDC: 6 to +10 % Note 1) Impact resistance: Made to Order Specifications (For details, refer to pages 1847.) Symbol Specifications No malfunction resulted from the impact test using a drop impact tester.
In-line Air Filter ZFC Series RoHS How to Order B 4 ZFC 5 Body size Symbol Body size Filtration area 1 5 L/min 140 mm2 3 10 L/min 470 mm2 Made to order Refer to page 8 for details.
The Actuator selection window will be displayed. b) Actuator selection Search for the connected actuator using the Search on the condition or Search from Part No. b-1) Search on the condition button button in the Result area Select the conditions of the actuator to be connected for the Model, Motor mounting, Lead, and Stroke as much as possible.
BUSY OFF 27 No.SFOD-OMT0011CN-A 4.2 (1) a) View(V) 4.1 (1-1-2) View (V) Actuator selection b) b-1) conditions Model Motor mounting Lead Stroke 28 No.SFOD-OMT0011CN-A b-2) Search from Part No.
Cylinder ports should be NAMUR hole pattern. 100/200 V (50/60 Hz) 24 V 15 to +10% of rated voltage Class B or equivalent 5.0 VA/60 Hz, 5.6 VA/50 Hz 2.3 VA (1.5 W)/60 Hz, 3.4 VA (2.1 W) 9/50 Hz 1.8 W VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 VT VP 3 1 AC
2 I/O cable length*1, Communication plug Nil Without cable (Without communication plug connector)*3 1 1.5 m 3 3 m*2 (Programless type) NPN 1P PNP 5 5 m*2 A 10 m* MJ LECPMJ*2 *3 (CC-Link direct input type) S Straight type communication plug connector*3 B 15 m* T T-branch type communication plug connector*3 C 20 m* AN LECPA*2 *4 (Pulse input type) NPN AP PNP *1 When Without controller/driver
17.5 IDW04N 29 4 20 IDW06N 31 6 22 IDW08N 33 8 11 3.6 25 IDW10N 3/8" 36 10 32 IDW15N 43 15 42 IDW25N 53 25 57.5 Simplex IDW35N 68 35 28.0 IDW45N 117 45 31.8 3/4" IDW55N 130 55 36.0 IDW65N 141 65 7 43.5 IDW85N 85 165 1" 55.8 IDW105N 105 200 20.5 63.5 IDW135N 135 224 1-1/4" 79.5 IDW175N 175 271 55.8 IDW215N 215 378 13.5 63.5 Duplex 1-1/2" IDW275N 275 422 79.5 IDW365N 365 510 1.