Designation Contact layout Power supply connector Power supply with load voltage for valves (M12 4-pole plug, A-coded) 3 1 Diagnostic information The technical document states detail diagnostic information can be found on the SMC website (URL http://www.smcworld.com) 2 1 4 Ground terminal Functional earth (M3 screw) 2 +24 V for solenoid valve 5 Output connector Output signal interface for
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 2 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
M3 hexagon screw Tightening torque 0.6 Nm Troubleshooting If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation.
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4x20) with washer, 1 pc.
Real-time switch output Unit switching Hysteresis mode ON YES Accumulated flow l Display Real-time flow rate l/min OFF P-1 P-2 Real-time flow rate GPM gal (US) "P" Window comparator mode H : Hysteresis GPM = gal (US)/min H H Note) Fixed SI unit (l/min, l, m3 or m3x10) will be set for the type without the unit switching function.
Dimensions L A LA Attached from top W C PA MM Note 1) M F HB HA Note 2) Attached from bottom: MD R Body B (mm) Note 1) Note 2) B C F HA HB L LA MM MD M PA R W A Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 16 35 6.5 5.5 16.5 23 57 25 M4 x 0.7 M3 4 25 6 36 18 36 6.5 5.5 17 23.5 66 30 M4 x 0.7 M3 4 27 6 37 20 46 8.0 5.5 21 28.5 70 30 M5 x 0.8 M4 5 36 7 47 22.5 60 9.5 6.0 27.5 36 80 35 M6 x 1.0
Hexagon socket head cap screw Round head Phillips screw With spring washer, M3 x 0.5 x 14 L With spring washer, M3 x 0.5 x 16 L Switch mounting fitting Magnetic field resistant auto switch Mounting bracket kit number Items and number of each item Switch mounting bracket x 1 Switch mounting nut x 1 Round head Phillips screw x 1 Hexagon socket head cap screw x 2 Spring washer x 4 BQP1-
Assembly is required. 7 Technical Data Pressure dew point Condensed water calculation Atmospheric pressure 45 Relative humidity 100% 40 0.1MPa Amount of water in air g /m3 35 80% 60% 0.2 40% 0.3 0.4 0.5 30 0.6 0.7 0.8 25 Amount of condensed water 20% 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 0 5 Intake air temperature C (atmospheric pressure) Air temperature (Pressure
M1 W 10 50 100 L1 10 30 20 0 0 2 4 6 8 10 0 1 2 3 4 5 Work load (W) kg Work load (W) kg Work load (W) kg 300 30 150 L2 200 20 M2 100 L2 mm L2 mm L2 mm W 100 10 50 L2 M2 0 10 30 20 0 1 2 3 4 5 0 2 4 6 8 10 Work load (W) kg Work load (W)kg Work load (W) kg 30 300 150 a=500 a=500 a=500 Horizontal/Lateral a=1000 a=1000 a=1000 20 200 100 a=2000 a=2000 L3 mm L3 mm L3 mm a=2000 L3 100 10 50 W M3
Torque Recommended torque in lbf (N m) Hexagonal wrench width across flats Type Fixing thread size 1.5 5.3 (0.6) MXW 8 M3 x 4 1.5 5.3 (0.6) MXW12 M3 x 4 1.5 MXW16 M3 x 4 5.3 (0.6) 2 MXW20 M4 x 5 7.1 (0.8) 2.5 MXW25 M5 x 6 8.9 (1) 139 MXW Series Long Stroke Slide Table Operation Guide Maximum dynamic load and allowable moments are different depending on work mounting orientation,cylinder
Switch mounting screws (M3 x 0.5 x 10l) Switch spacer 32, 40 50, 63 Manufacture of intermediate strokes BQ-2 Method Spacers installed in standard stroke body. Switch mounting nut Ordering Refer to standard part number and ordering on page 1.
M1 F KK 1/4 1/4 C side A side (E1,E1,E2,E2,E3,E3): Reference dimension for the inserted tubing from the end surface of the nut (E1,E2,E3),L1,L2,L3: Nut material PVDF dimensions H1 H3 (E3,E3) (E1,E1) L3,L3 L1,L1 G D Metric Size MS Model B B side (Center) A side (Left) C side (Right) E1 E1 E2 E2 E3 E3 F G H1 H2 H3 L1 L1 L2 L2 L3 L3 M1 M2 M3 Applicable tubing O.D.
Vertical mounting: 0 (None) The moment load rate must be calculated in accordance with the above formula for all types, M1 to M3. As for Wmax and Mn, refer to the maximum load mass and allowable moment table in the next section. The moment for the inclined mounting must be calculated taking the moment caused by the load into consideration.
Tightening the threaded portion of an M3 fitting For KJS02-M3 (one-touch fitting), tighten it with a tightening tool by approx. 1/6 rotation after screwing it in by hand. Screwing the fitting in too far will cause air leakage due to thread breakage and gasket deformation. Screwing the fitting not far enough will also cause air leakage due to the loose screw. 1.
/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2 x 3 x 60 = 2736g/h. 6 7 8 3 1 2 3 4 5 Dew Point Conversion Chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 -40 -30 -20 -10 -60 -50 -60 -50 -40 -30 -20 -10 0 10 20 30 Atmospheric
Switch mounting screws (M3 x 0.5 x 10l) Switch spacer 32, 40 50, 63 RS H A Manufacture of Intermediate Stroke BQ-2 Method Spacers installed in standard stroke body. Switch mounting nut RZQ Ordering Refer to standard part number and ordering on page 10-10-2.
Check the detecting position again and tighten the mounting screw to fix the auto switch definitely (the tightening torque of M3 screw should be about 50 to 70 N/cm). 5. Modification of the detecting position should be made following step #3. C76 C85 C95 Auto Switch Mounting Band Part No.
Vertical mounting: 0 (None) Data NO Confirmation of sum of load ratio to the guide unit n 1 The moment load rate must be calculated in accordance with the above formula for all types, M1 to M3. As for Wmax and Mn, refer to the maximum load mass and allowable moment table in the next section.
diameter: M3, Mounting connection screw: M3 × 0.5, With/without lock ring: -, Type: With adapter, Detachability: Improved detachability (blast specifications)