Rp 3/4 socket 1B union 1 1/2B union Rc 3/8 (Rc 3/8) 24 Rc 1/2 (Rc 3/8) 55 36 18 Munsell N-8 (White), Munsell 2.5PB5/8.5 (Blue) 37 22 15 7.5 Thermometer for outlet air temp. (1 pc.) Drain valve (1 pc.) Union (2 pcs.)
1/8 56 57.5 30 14 41 40 5.5 M6 x 1 Rc 1/8 62 64.5 30 14 49 50 6.6 M8 x 1.25 Rc 1/4 61.5 76.5 35 19 49 60 9 M10 x 1.5 Rc 1/4 64 89.5 35 19 For rod nut and accessory bracket, refer to page 10-12-20.
(Example) 40D-A3C-4, 63D-A3C-6, 100D-A3C-10 50D-A3C-5, 80D-A3C-8 1.08 0.32 0.38 0.38 0.73 Double knuckle Accessory bracket 0.19 0.05 0.05 0.05 0.14 Knuckle pin 10-12-49 7 Series CE2 Dimensions: 40 to 100 RC 1/4 Pressurized locking port RC P Rod side cylinder port RC P Head side cylinder port Basic style RC 1/4 Unlocking port Unlocked when pressurized 7 (6 core twisted pair shielded wire)
1/8 8 M8 x 1.25 13 25 8.5 97.5 151 31.5 40.5 28.5 20.5 33 29 25 M26 x 1.5 18 Rc 1/8 10 M10 x 1.25 13 30 8.5 102.5 160 34.5 44.5 32 20.5 38 32 For details on rod end nut and mounting nut, refer to page 10-5-24. 10-5-20 20 Low Friction Cylinder: Anti-lateral Load Type Metal Seal Series MQM For other dimensions, refer to basic style on page 10-5-20.
For Rc, leave the symbol blank, and for NPT, enter N. Please consult with SMC for the supply of a pressure gauge with NPT port threads. Note 2) Use caution not to tighten excessively when mounting a pressure gauge, otherwise it will may result in a breakdown. For sealing, use a pipe tape. Torque recommended: (R 1/8: 7 to 14 Nm).
Rc 1/8 relief port Port for extending cylinder Port for retracting cylinder 8-23-8 9 Guide Table Series MGF Construction @2 !2 y u !3 e q t r o w @0 !1 !7 !8 !9 !5 !6 !0 MX i MTS @4 MY CY MG @1 !
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 or less (Within allowable torque values) 0.2 or less (within allowable torque values) Non-rotating accuracy Piping port size M5 x 0.8 Rc 1/8 Rc 1/8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M3 x 0.5 Except lock unit, 0.12 MPa for 12 and 16; 0.10 MPa for 20 to 40
Pipe thread type Name plate in imperial units Pressure gauge in imperial units Sales Note 6) G EA, EB, EC, ED Nil Rc MPa MPa Fixed SI unit Japan, Overseas NPT G Rc Only overseas NPT psi psi With unit conversion function (Initial value psi) G Z Note 4) Note 4) For pipe thread type: NPT Note 5) For options: EA, EB, EC, ED Note 6) According to the new Measurement Law, only the SI unit type is
Grease pack part number: GR-S-010 (10 g) M3, M5, Rc port, NPT port Use the correct tightening torques listed below.
Use a commercially available belt wrench etc. for mounting and removing clamp rings. 68 High Precision Filter for Liquids FGH Series Dimensions FGD FGE FGG FGA FGC FGH100/200 FGH300 FGF FGH FGH 2 x Rc 2 x Rc M6 M6 FQ1 FN EB ES Pull-out dimension Pull-out dimension Dimensions A B Element length Port size (Rc) Model 3/8, 1/2 235 FGH100 70 x L117 211 3/4, 1 240 364 3/8, 1/2 FGH200 70 x L246
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM Operating pressure Port size Rated flow rate Model Model/Rated Flow Rate Rated flow rate (L/min) Model Threaded connection Flange connection Port size Operating pressure Threaded connection Flange connection Threaded Rc Flange SSA Threaded Rc Flange SSA (L/min) FH340-03 FH340-04 FH342-06 FH342-08 FH340-10 FH340-12 FH540-03 FH540
No indication is necessary for an Rc thread; however, indicate N for an NPT thread, and F for a G thread. (For auto drain, Nil: 10, N: 3/8") Please contact SMC separately for psi and F unit display specifications. Option/Part Nos. Description Part number 20 30 40 50, 60 Bracket assembly AF24P-070AS AF34P-070AS AF44P-070AS AF54P-070AS Auto drain Refer to Bowl Assembly/Part Nos.
Example) ARP30K-03BE-1RY Symbol 20 30 40 Body size Description Nil K Without backflow function With backflow function With backflow function + Nil N F Rc NPT G Thread type + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) a Without mounting option With bracket With set nut (For panel mount) Mounting H + Note 1) Nil E G E1 Note 3) Without pressure gauge Square embedded type pressure
Example) ARP30K-03BE-1RY Symbol 20 30 40 Body size Description Nil K Without backflow function With backflow function With backflow function + Nil N F Rc NPT G Thread type + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) a Without mounting option With bracket With set nut (For panel mount) Mounting H + Note 1) Nil E G E1 Note 3) Without pressure gauge Square embedded type pressure
Nq Body size 10 20 25 30 40 Symbol Description Nw Pipe thread type Nil Metric thread (M5) V Rc V V V V N NPT V V V V F G V V V V + M5 M5 V 01 1/8 V 02 1/4 V V V V 03 3/8 V V V 04 1/2 V 06 3/4 V + Ne Port size a Mounting Nil Without mounting option V V V V V B Note 2) With bracket V V V V V H With set nut (for panel mount) Note 3) V V V V V + Option Note 1) Nr Nil Without pressure gauge
Example) AR30-03BG-NR-B-X425 Symbol Description Nq Body size 25 30 40 50 60 Symbol Description Nq Body size 20 25 30 40 50 60 Nw Pipe thread type Nil Rc N NPT F G + Nw Pipe thread type Nil Rc N NPT F G + 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size Nil Without mounting option B*2 With bracket a Mounting Option *1 H With set nut (for
Metal piping attachment Indicator LED (OUT1) Indicator LED (OUT2) Lock ring Function selection mode PFM7 button (SET) Nominal thread size Required torque S Connector Piping port (OUT side) Rc (NPT)1/8 7 to 9 Nm Rc (NPT)1/4 12 to 14 Nm Thank you for purchasing an SMC PFM7 Series Digital Flow Switch.
Nominal thread size Required torque Rc (NPT)1/8 7 to 9 Nm System error. The internal circuit may be damaged. Do not use the product for flammable fluid. A fire or explosion can result. Only dry air, N2, CO2 and Ar are applicable. System error Turn the power off and turn it on again. POWER FLOW Rc (NPT)1/4 12 to 14 Nm Section A Section C Power indicator is red.
. -14No.PF-OMO0007CN 90270 IN OUT M4(4) 1.6 mm (39) -15No.PF-OMO0007CN 1.0 MPa IN8 IN IN OUT D D8 () () Rc(NPT)1/8 79 Nm Rc(NPT)1/4 1214 Nm Rc(NPT)3/8 2224 Nm Rc(NPT)1/2 2830 Nm PF2A710 PF2A750 24 mm PF2A711 30 mm PF2A721 PF2A751 -16No.PF-OMO0007CN FG PF2A7 1 DC(+) 2 OUT2 3 DC(-) 4 OUT1 -17No.PF-OMO0007CN PF2A7 NPN2(2) PF2A7--27DC(+) OUT1 OUT2 DC1224V DC(-) Max.30 V80 mA 1
(NPT)1/8 7 to 9 Nm PF2W704(T) Window comparator mode Bracket [F_2] Input the Set value of instantaneous output (Auto-preset) 34 mm Rc(NPT)1/4 12 to 14 Nm Selection of switch operation (OUT1) [1_n] Reverse output PF2W720(T) : This drawing is the model of PF2A710/750. 22 to 24 Nm Selection of switch operation (OUT2) [2_n] Reverse output Rc(NPT)3/8 PF2W740(T) ( ) Hysteresis Set point 2 Set point