Series LECP6 controller has two available modes for the setting software and teaching box.  In the easy mode, the operation can be started by only setting the speed, position, etc.  Using the normal mode allows a further detailed setup.  A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 4.35618 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 1.825 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 4.35618 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 4.35618 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 4.35618 lb

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

(page 72) 0x04C4 (1220) 0x04C5 (1221) 0x04C6 (1222) 0x04C7 (1223) Y S16 0x0258 4 R/W (600) WH1 (Setting of OUT1 window comparator hysteresis) Setting of OUT1 window comparator hysteresis.

Max. 150 NL/min 3000 NL/min PF2A703H 5.5 CFM 106.0 CFM 300 NL/min 6000 NL/min PF2A706H 10.5 CFM 212.0 CFM 600 NL/min 12000 NL/min PF2A712H 21.0 CFM 423.5 CFM : Analogue output is based on the rated flow range at normal condition. Displayed flow range is based on standard condition. Therefore, the range of rated flow and the displayed flow are different..

10 to 100 20 to 200 50 to 500 L/min L/min L/min L/min L/min Pressure Rated pressure range -50 kPa to 0.5 MPa -50 kPa to 0.75 MPa Proof pressure 1.0 MPa Output for PF2A3 Analogue voltage output (non-linear), Output impedance: 1 k Voltage output 1 to 5 V Output impedance 1 k Analogue output Current output 4 to 20 mA Load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600

. -19No.PF-OMO0014-D Output for PF2W3 + Analogue (4 to 20 mA) type PF2W5--2Analogue output: 4 to 20 mA Load impedance: 300 (12 VDC) 600 (24 VDC) 1: Refer to the PF2W3 operation manual for details of the flow monitor. 3: Load indicates analogue input equipment such as an ammeter. -20No.PF-OMO0014-D Troubleshooting Troubleshooting If an operation failure occurs with the product, use the chart

Min. load impedance: 100 k (Output impedance: 1 k) Analogue output Current output: 4 to 20 mA, Accuracy: 2%F.S. or less Max. load impedance: 300 or less with 12 VDC, 600 or less with 24 VDC Supply voltage 12 to 24 VDC 10% Power consumption (No load) 20 mA or less Enclosure IP65 Environment Operating temperature range Operation: 0 to 50 C, Storage: -25 to 85 C (no condensation or freezing

. -42No.PF-OMW0004-B Model PF3W704 PF3W720 PF3W740 Response time 6 0.5 s/1 s/2 s Analogue output Voltage output Output voltage: 1 to 5 V, Output impedance: 1 k Current output Output current: 4 to 20 mA Maximum load impedance: 300 for 12 VDC, 600 for 24 VDC Hysteresis Variable External input Voltage free input of 0.4 V or less (reed or solid state type) for 30 ms or longer 2-screen display

Analogue output 4 to 20mA Max. load impedance 600 -22No.LV50***-OMQ0002-G Example of wiring for accumulated pulse output NPN 2 output type LFEA NPN + Analogue output type LFEC LFED Black OUT1 Or Load White OUT2 (LFEA only) Load Blue DC(-) Brown DC(+) Black OUT1 Or Load White OUT2 Load PNP 2 output type LFEB * When accumulated pulse output is selected, the indicator LED will be turned OFF

NPT)1 3638 Nm NG NG 19 No.LFE*-OMY0008 NG IN 5 (5D)(68 ) 20 No.LFE*-OMY0008 FG 3 1 DC() 4 2 2 OUT2 3 DC() 1 4 OUT1 3 4 2 1 DC() 2 OUT2 3 DC() 1 4 OUT1 LFE M12 21 No.LFE*-OMY0008 NPN2 LFEA PNP2 LFEB DC() OUT1 OUT2 DC() OUT1 DC24V DC24V DC() DC() Max.28 V80 mA 1 V Max.80 mA 1.5 V NPN LFEC NPN LFED DC() OUT1 OUT2 DC() OUT1 OUT2 DC24V DC24V DC() DC() Max.28 V80 mA 1 V 420 mA 600

. -20No.LFE*-OMZ0012 Internal Circuit and Wiring examples Analogue voltage output type Analogue current output type LFEJ(Z) LFEK(Z) Brown DC (+) Brown DC (+) Black NC Black NC Main circuit Main circuit White OUT2 White OUT2 24VDC 24VDC Load Load Blue DC (-) Blue DC (-) Analogue output 1 to 5 V Output impedance 1k Analogue output 4 to 20mA Load impedance 50 to 600 In the isolated type, the

Current output Output current: 4 to 20 mA Max. load impedance 600 Hysteresis Variable Input and output Input for copy mode 2 screen display (Main screen: 4 digit, 7-segment, 2 colour; red/green, Sub screen: 6 Display type digit, 11 segment, White) Display updating interval 5 times/sec.