SMC Corporation of America
Elite Part Number Search
Search Results "AS2001FM-04-J"

(mm) Stroke range Bore size (mm) I J K M B D C E KA GA GB H 51 57 66 78 92 110 144 M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M8 x 1.25 M12 x 1.75 8 8 10 10 14 14 20 11 12 22 25 25 25 25 25 30 36 45 55 68 87 11 12 16 21 26 32 36 21 24 30 36 46 53 65 16 26 28.5 34.5 40 46.5 54 20 21 35 40 45 50 50 29 33 38 46 55 66 86 39 43 49 59 71 82 106 20 25 32 40 50 63 80 12.5 18 19.5 23.5 28 34.5 36 Up

A + Stroke 20Data Common Dimensions: MVGPM/MVGPL B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) ID IE IF IG IH J K L 20 25 32 9.5 10 9 79.5 10 10 12 32.5 8.5 9 9 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 83 93 112 6 7.5 9 24 30 34 M5 M5 M6 32 18 21 24 3 20, 30, 40, 50, 75, 100, 125 150, 175, 200,

J J J G G G G B B B B A A A A A A A A Model A B C D E Fn G H J K XLC-25 50 120 48 1 12 40 26 39 27.5 8 XLC-40 65 171 66 2 11 55 41 63 36 9 8 XL-OMO0001-A 5 Guaranteed period and range The warranty period is 2 million cycles (under SMC endurance test conditions), 18 months after delivery or 12 months in service, whichever comes first.

Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.

A + Stroke 20Data Common Dimensions: MVGPM/MVGPL B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) ID IE IF IG IH J K L 20 25 32 9.5 10 9 79.5 10 10 12 32.5 8.5 9 9 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 83 93 112 6 7.5 9 24 30 34 M5 M5 M6 32 18 21 24 3 20, 30, 40, 50, 75, 100, 125 150, 175, 200,

Intermediate strokes at 1mm intervals are available by using exclusive body with requied stroke. products of CQS series Allowable Kinetic Energy Unit: J Bore size (mm) Stroke range Stroke range Stroke range Bore size Bore size 12 16 20 25 6 to 30 12, 16 1 to 30 12, 16 6 to 50 20, 25 1 to 50 20, 25 Standard 0.022 0.038 0.055 0.09 Method Long stroke Intermediate strokes at 1mm intervals are

Series CU comparison Allowable kinetic energy (J) Noise reduction of more than 11dB is possible (compared to Series CU20 with rubber bumper). : with air cushion : with rubber bumper 3 Interchangeable mounting Mounting dimensions (J, K, R, and E) are the same as the rubber bumper type Series CU. 2 1 0.70 0.44 0.11 0.28 0.29 0. 18 R 20 25 32 Bore size (mm) E Improved repeatability When compared

J 8-L counter bore A + Stroke M M CHKDB20 & 25 CHKDB32 to 100 Width across flats f c a b g e h + Stroke Rod end male thread (mm) F L A B C D E G H J K M P Q R Bore size (mm) 20 M8 x 1.25 9.5 depth 5.4 51 43 8 12 10 10 6 30 5.5 43 1/8 16.5 6 25 M10 x 1.5 9.5 depth 5.4 53 45 8 14 12 12 6 36 5.5 49 1/8 17 8 32 M12 x 1.75 11 depth 6.5 61 51 10 18 14 15 7 47 6.6 63 1/4 19.5 10 40 M16 x 2 14 depth

Shock absorber specifications Piston speed 40 Bore size (mm) 16 25 RB 0806 RB 1007 RB 1412 RB 2015 RB 2725 Model Without stroke adjusting unit 100 to 1000mm/s Note 1) Max. energy absorption (J) L unit and H unit Stroke adjusting unit 2.9 5.9 19.6 58.8 147 100 to 1500mm/s Stroke absorption (mm) 6 7 12 15 25 Note 1) When exceeding the air cushion stroke ranges on features page 8, the piston

See pages 31-39 for more information on SMC'S LC6 series drivers, Seiles uff EleGriGlcMflors 0inrmh$l$till$swm LXFH5B (30Omm) ft hlor-T;+ -r-I "kl T slot dimensions (21 ) J I shows the location ai which origjn poinl swirch opetales.

“JF80-22-150” is the part number of the old floating joint, the J series. The J series (J□, JF□, and JL□) was discontinued in 1990 and became the current JA series. The mounting dimensions of JA series joints are not interchangeable because J series joints were of the compact type.

Port size AS-D U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 AS-T ASP Needle Valve/Flow Rate Characteristics ASN AS2201FSl-U02, AS2211FSl-U02 AS2201FSl-U01, AS2211FSl-U01 300 600 AQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 500 ASV 06, 07, 08, 09, 10 08, 09, 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 03, 04 06, 07 200 400 AK 01, 23 300 VCHC 03, 04 100 200 ASR ASQ 01, 23

VHS400-02 VHS401-02 VHS400-03 VHS401-03 VHS400-04 VHS401-04 VHS500-06 VHS501-06 Pipipng direction Port size 3 4 1 2 3 8 1 4 1(P) 2(A) 21 105 76 54 35 35 57 93 Effective area (mm2) Mass (kg) 2(A) 3(R) 0.25 0.34 The front face of the handle is the reference position. Easy to Operate The direction of air flow can be verified at a glance by the orientation of the handle.

Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

FGDTF*-04 FGD-CV005-06 FGDTF*-06 (5) FGD-CV006-03 FGDCE*-03 FGD-CV006-04 FGDCE*-04 FGD-CV006-06 FGDCE*-06 FGD-OP001 FGD*B (10) KT-FGDC FGDC KT-FGDE FGDE (2)(4)(6)(13)(16) KT-FGDT FGDT KT-FGDF FGDF FGD-CA002 FGDT,F(L250) (7)(9)(11)(12)(13) (14)(15)(16)(17) FGD-CA003 FGDT,F(L500) L500 (18) FGD-CA004 FGDC,E(L250) FGD-CA005 FGDC,E(L500) 7/11 FGX-OM-L007-C 2. 2.

M Weight (g) AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 Model Applicable tubing O.D. d 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 27.9 28.2 29.6 32.4 40.2 32.5 33.1

04 0 5 VK Thread type Series VP 5 port solenoid valve Manifold Nil Rc VZ G F N NPT Base size NPTF T VF Common EXH 5 6 3 4 A/B Port size 1 VFR Symbol Port size 04 06 10 M Note) 1 Mixed VVP460 VVP450 1 2 3 4 VP4 Porting specifications Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Body size (Base size) 2 3 4 6 1/4 base 3/8 base 1/2 base 1 base Port size (Nominal size) 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Piping/Mounting Piping Note) Mounting method Body Panel mounting Body Panel mounting Symbol 0 1 2 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com