Fig.11 Component parts of MSUA1/3 switch unit No.
4 7 1 4 11 2 1 2 2 9 Note) Only bracket or foot may be mounted. 14-10-2 E-P HYREG Series VY1 Standard Specifications 02 03 04 04 06 10 02 03 04 VY1A0 0 1-M5 VY1B0 0 1M 0 5 1 VY110 0 10 0 1 2 VY120 0 10 0 1 2 VY130 0 1VY140 0 1VY150 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 Model VY1D00-M5 10 M5 01 M5 Port M5 01 02 01 02 02 03 20 04 02 03 04 04 06 10 12 14 P Port size Rc 11 2 1 1 8 1 8 1 4 1
U side 1 2 3 4 5 n Direct manual override (Non-locking) 2n x C4, M5 4(A), 2(B) port C4: One-touch fitting for 4 M5: M5 thread 2(B) 2(B) 27.5 20 15 4(A) 4(A) 5 P = 11 12.5 (46) L plug connector (L) n: Stations Dimensions n L 11 138 130 10 127 119 L1 L2 2 39 31 3 50 42 4 61 53 5 72 64 6 83 75 7 94 86 8 105 97 9 116 108 12 149 141 13 160 152 14 171 163 15 182 174 16 193 185 17 204 196 18 215
Terminal part no. 1 10 2 11 3 12 4 13 5 14 6 15 7 16 8 17 9 18 A mark is located on the connector number 1 side. 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 View from the insertion side View from the wiring side Switches Home position switch: This switch indicates the home position. Connect this switch when returning to the origin point.
O.D. 6 KFE06-02 KFE08U-03 KFE08N-03 KFE10U-03 KFE10N-03 KFE12U-03 KFE12N-03 4 5 6 6.5 7.5 8 9 1 4 41 49 50 63 62 93 91 37.5 17 12 17 44.2 16 15.2 3 4 5 5.5 6.5 7 8 M10 x 1 11 6 11 17 21 30 35 45 13 8 M12 x 1 3 8 17 46.2 39.5 16.2 19 14 19 3 8 M15 x 1 16 10 17 48.8 41.5 18.8 19 17 22 Connection thread Applicable tubing Mounting plate thickness 4 mm or less 18 12 3 8 17 51.3 44.5 19.3 22 19
M Weight (g) Model Applicable tubing O.D. d T Uni thread 1 8" AS221F-U01-01 AS221F-U01-03 AS221F-U01-05 AS221F-U01-07 AS221F-U01-09 AS221F-U02-03 AS221F-U02-05 AS221F-U02-07 AS221F-U02-09 AS221F-U02-11 AS321F-U02-07 AS321F-U02-09 AS321F-U02-11 AS321F-U03-07 AS321F-U03-09 AS321F-U03-11 AS421F-U04-11 AS421F-U04-13 7.8 8.9 11.4 13.2 15.2 8.9 11.4 13.2 15.2 17.9 13.2 15.2 17.9 13.2 15.2 17.9
03, 04 100 200 01, 23 100 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations AS4201F, AS4211F AS4301F, AS4311F AS3201F, AS3211F AS3301F, AS3311F 10, 11, 12 12, 13, 16 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 1500 1000 08, 09 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 06, 07 1000 500 500 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations
(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 end 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
7 NBR Valve retainer seal #7 * Since ther is a possibility of improper operation, contact SMC regarding the replacement of seals. 4.4-9 Series CE1 Dimensions 12, 20 Both ends tapped CE1B Bore size Stroke (mm) A B C D E G H I K L M Bore (mm) 12 20 Standard stroke 25, 50, 75, 100, 125, 150 94 M5 X 0.8 16 5.2 25 15.5 69 15 6 25 42.5 25, 50, 75, 100, 125, 150, 175, 200 106 78 15.5 10 36 53.5
Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Made to Order: Individual Specifications (For details, refer to pages 1538 and 1539.) 6 10 300 500 50, 100, 150, 200 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350 400, 450, 500 Symbol Specifications -X116 -X168 -X322 -X431 Hydro specifications 15 750 Helical insert thread specifications 20 25
Series CBQ2 Allowable Kinetic Energy Allowable Rod End Lateral Load 0.5MPa 0.4MPa With rubber bumper With auto switch (lateral resistance) 200 100 100 50 50 40 30 Allowable lateral load W (N) 63 20 Load weight kg 50 10 63 40 32 10 5 4 3 50 5 2 40 1 0 10 20 30 40 50 60 70 80 90 100 32 Stroke St (mm) 1 50 100 200 500 300 Maximum speed mm/s (Mounting orientation: Horizontal) W
VCW 20 1 G Clip Series Lead wire length 20 30 40 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 Class 2 Class 3 Class 4 Flat head screwdriver Voltage Solenoid coil 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Electrical entry Insert a flat head screwdriver into the hook section of the clip groove.
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2.
(M8(3 )11 ) 01 X M ISE40A 2 K ISE40A -0.11.000 MPa ZSE40A 0.0-101.3 kPa ZSE40AF -100.0100 kPa 1 01 R1/8 (M5) A A N01 NPT1/8 (M5) W1 Rc1/8 B B WF1 G1/81 D D M5 M5X0.8 () E C4 4 C6 6 F + 1IS0228-1 P10/1 X NPN2() Y PNP2() 1 R NPN2 +/ T PNP2 +/ M SI2 P (psi)1 S NPN2 +/ 1 2kPaMPa V PNP2 +/ -9No.PS-OMM0006CN-E /1 1 01 N01 W1 WF1 M5 C4 C6 A A ZS-24-A X X X B B ZS-24-B X X X X X D
SF BF: () (PLC) LED 27 PROFIBUS DP SF: BF PROFIBUS DP 11 SF BF SI 0126 1~125 SF BF PLC SF: BF SI PLC V_SEL PLC SI PWR LED DC24 V+10/-5 SI ~ SI 12 SI EX600-SPR1A (PNP ) EX600-SPR2A (NPN ) SI SI -49No.EX-OMN0027CN-D No. (PNPNPN) SI PWR LED DC24 V10% 13 (PNPNPN) SI PWR LED DC24 V+10/-5 PLC -50No.EX-OMN0027CN-D No.
34.9 63.7 58.3 22 AS3001F-07-3 1/4" 13.2 59 7.4 31.3 60.1 54.7 17 100 84 12 20.9 AS4001F-10-3 77.7 AS3001F-09-3 82.1 11.3 35 69.3 61 21 5/16" 21 15.2 32.1 3.5 60.9 55.5 18 64.4 8.2 167 88 18.5 16 10 18.5 27 21 24.5 3.5 AS4001F-12-3 36 70.3 62 22 AS3001F-11-3 3/8" 17.2 33.3 62.1 56.7 21 70.8 9.5 171 95 12 20.9 Note 1) Reference dimensions AS4001F-11-3 3/8" 27 21 17.9 34.9 3.5 69.2 60.9 21
Applicable bore size B2 C2 d H2 SNJ-010C 10 11 12.7 M8 x 1.0 4 NTJ-010C 10 7 8.1 M4 x 0.7 3.2 Y-J016C 16 11 16.6 21 M5 x 0.8 SNJ-016C 16 14 16.2 M10 x 1.0 4 Part no. NDd9 NDH10 NX R1 U1 Y-J010C 3.30.030 0.060 3.3+0.048 0 3.2 8 10 NTJ-015C 16 8 9.2 M5 x 0.8 4 Y-J016C 50.030 0.060 5+0.048 0 6.5 12 10 * A knuckle pin and retaining rings are included.
6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AM AFF2B 1 8 1 4 3 8 166 187 187 218 218 241 241 277 334 24 27 27 32 32 37 37 39 55 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253
Varistor 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Neon bulb When 100 VAC or more Coil Note 1) The tightening torque should be within 0.5Nm +/15%. Note 2) Cable (7) external: 6 to 8 mm. Note 3) Crimped terminal like round-shape or Y shape cannot be used.