Port size 04 06 10 12 14 20 LVH 1 2 3 4 Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LVD 1 4 1 2 Thread type Nil T F N LVQ Rc NPTF G NPT Refer to the table (1) given below for availability.
Classification of Waterproof: Open Style (Non Water Proof), Pressure Range: 0.02~0.3MPa, Fluid Contact Area Material: SUS316, Thread: R(PT), Differential Scale Plate: Differential Scale, Electric Wire Gland: -, Contacts: -
Classification of Waterproof: Open Style (Non Water Proof), Pressure Range: 0.05~0.7MPa, Fluid Contact Area Material: SUS316, Thread: R(PT), Differential Scale Plate: Differential Scale, Electric Wire Gland: -, Contacts: -
Classification of Waterproof: 2 (Drip Proof), Pressure Range: 3 (0.1~1.0MPa), Fluid Contact Area Material: 0 (Brass, Phosphorus Bronze), Thread: R(PT), Differential Scale Plate: 1 (Differential Scale)
Classification of Waterproof: 2 (Drip Proof), Pressure Range: 2 (0.05~0.7MPa), Fluid Contact Area Material: 1 (SUS316), Thread: R(PT), Differential Scale Plate: 1 (Differential Scale)
Classification of Waterproof: 2 (Drip Proof), Pressure Range: 2 (0.05~0.7MPa), Fluid Contact Area Material: 0 (Brass, Phosphorus Bronze), Thread: R(PT), Differential Scale Plate: 1 (Differential Scale)
Classification of Waterproof: 2 (Drip Proof), Pressure Range: 1 (0.02~0.3MPa), Fluid Contact Area Material: 0 (Brass, Phosphorus Bronze), Thread: R(PT), Differential Scale Plate: 1 (Differential Scale)
Classification of Waterproof: 2 (Drip Proof), Pressure Range: 1 (0.02~0.3MPa), Fluid Contact Area Material: 1 (SUS316), Thread: R(PT), Differential Scale Plate: 1 (Differential Scale)
Classification of Waterproof: 2 (Drip Proof), Pressure Range: 3 (0.1~1.0MPa), Fluid Contact Area Material: 1 (SUS316), Thread: R(PT), Differential Scale Plate: 1 (Differential Scale)
Type: 100 (Rotary Type), Pressure Gauge: 3 (1.0MPa), Construction: 1 (w/Terminal Box)
Type: 000 (Lever Type Feedback), Pressure Gauge: 3 (1.0MPa), Construction: 1 (w/Terminal Box)
Thread Type: Rc, Port Size: 03 (IN: 3/8, OUT: 3/8), Voltage: 1 (100VAC 50/60HZ)
Type: Pressure Switch, Fluid Type: Air / Water / Nitrogen Gas / Argon, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [3/8] 3/8, Fluid Characteristics: Noncorrosive / Inert, Pressure Type: Positive Pressure, Number of Outputs: 1, Liquid contact parts material
Type: Pressure Switch, Fluid Type: Air / Water / Nitrogen Gas / Argon, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [3/8] 3/8, Fluid Characteristics: Noncorrosive / Inert, Pressure Type: Positive Pressure, Number of Outputs: 1, Liquid contact parts material
Type: Pressure Switch, Fluid Type: Air / Water / Nitrogen Gas / Argon, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [3/8] 3/8, Fluid Characteristics: Noncorrosive / Inert, Pressure Type: Positive Pressure, Number of Outputs: 1, Liquid contact parts material
Type: Pressure Switch, Fluid Type: Water, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [3/8] 3/8, Fluid Characteristics: Noncorrosive, Pressure Type: Positive Pressure, Number of Outputs: 1, Liquid contact parts material: [Stainless Steel] Stainless Steel
Type: Pressure Switch, Fluid Type: Air / Water / Nitrogen Gas / Argon, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [3/8] 3/8, Fluid Characteristics: Noncorrosive / Inert, Pressure Type: Positive Pressure, Number of Outputs: 1, Liquid contact parts material
Type: Pressure Switch, Fluid Type: Water, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [3/8] 3/8, Fluid Characteristics: Noncorrosive, Pressure Type: Positive Pressure, Number of Outputs: 1, Liquid contact parts material: [Stainless Steel] Stainless Steel
Type: Pressure Switch, Fluid Type: Air / Water / Nitrogen Gas / Argon, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [3/8] 3/8, Fluid Characteristics: Noncorrosive / Inert, Pressure Type: Positive Pressure, Number of Outputs: 1, Liquid contact parts material
Type: Pressure Switch, Fluid Type: Air / Water / Nitrogen Gas / Argon, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [3/8] 3/8, Fluid Characteristics: Noncorrosive / Inert, Pressure Type: Positive Pressure, Number of Outputs: 1, Liquid contact parts material