Common exhaust Individual exhaust 10 VT315-OMH0002-D TROUBLE SHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.

Bad characteristic Plugged restrictor Disassemble and clean Deformed diaphragm Replace diaphragm -9- No.IL01-OM06-C -10- No.IL01-OM06-C -11- No.IL01-OM06-C Safety instructions update Drawings update Spare parts list, Drawings update 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject

This may cause misalignment of the pressure gauge pointer. -10- Operation Warning (1) Do not use a precision regulator outside the range of its specifications as this can cause failure.(Refer to the specifications.) (2) Screw a panel nut with the recommended proper torque 12.5Nm when mounting onto a panel.

Check wiring. 10 If any abnormality is found, perform checks according to the following list. If the abnormality cannot be eliminated, contact your SMC representative. Discharge fluids from the pump. Eliminate the residual fluids, and thoroughly clean the product with pure water or air.

In the case of diodes, the residual voltage is approximately 1V. 10. Extended periods of continuous energization. If a valve will be continuously energized for an extended period of time, the temperature of the valve will increase due to the heat generated by the coil assembly. This will likely adversely affect the performance of the valve and any nearby peripheral equipment.

If alignment is not adequate, operation failure or breakage of the actuating cylinder or lock unit can result. 10 - Fig. 3.Example when operated with the rodless cylinder 2-3. Mounting The foot mounting cylinder has a hole in the foot to drive a pin into for accurate positioning and fixing.

The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, 2-Color Hi Precision Dig Pres Switch, VACUUM SWITCH, ZSE40, ZSE40A, 101 lb

The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, 2-Color Hi Precision Dig Pres Switch, VACUUM SWITCH, ZSE40, ZSE40A, 101 lb

101 kPa1 to 10% of the set pressure (Changeable)?1% full span or less?3% full span or less12 to 24 VDC (Ripple ?10% or less )NPN open collector 30 V, Max. 80 mA1 pointLights up when ON200 degrees17 mA or less (When 24 VDC is ON)--0.2 MPa

101 kPa1 to 10% of the set pressure (Changeable)?1% full span or less?3% full span or less12 to 24 VDC (Ripple ?10% or less )NPN open collector 30 V, Max. 80 mA1 pointLights up when ON200 degrees17 mA or less (When 24 VDC is ON)--0.2 MPa

101 kPa1 to 10% of the set pressure (Changeable)?1% full span or less?3% full span or less12 to 24 VDC (Ripple ?10% or less )NPN open collector 30 V, Max. 80 mA1 pointLights up when ON3 rotations17 mA or less (When 24 VDC is ON)--0.2 MPa

101 kPa1 to 10% of the set pressure (Changeable)?1% full span or less?3% full span or less12 to 24 VDC (Ripple ?10% or less )PNP open collector 80 mA1 pointLights up when ON (Red)200 degrees17 mA or less (When 24 VDC is ON)--0.2 MPa

101 kPa10 to 0 kPa500 kPaAir/Non-corrosive, non-flammable gas12 to 24 VDC ?10%, Ripple (P-P)10% or less (With power supply polarity protection)1 output: 17 mA or less at 24 VDC, 2 output: 25 mA or less at 24 VDC5 ms or less?1% F.S. or lessEnclosureOperating temperature rangeOperating humidity rangeVibration resistanceImpact resistance?3% F.S. or less1000 VAC for 1 min.