121 141 161 181 201 IN 151 30 45 60 75 90 106 121 136 151 -XC88 Spatter resistant coil scraper, Lube-retainer, Grease for welding (Rod parts: Stainless steel 304) 20 10 OUT 314 63 94 126 157 188 220 251 283 314 IN 236 47 71 94 118 141 165 188 212 236 -XC89W Spatter resistant coil scraper, Lube-retainer, Grease for welding (Rod parts: S45C) 25 10 OUT 491 98 147 196 245 295 344 393 442 491
If the product has failed, then please return the electro-pneumatic hybrid regulatorc as it is. 10 VY-OMK0001-C Revision history CE ARenewal WQ 1st printing : 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer
If a silencer is connected, the specified vacuum performance is reduced by 10% or less. 10. One-touch fittings Refer to the Fittings and Tubing Precautions on the SMC website for handling One-touch fittings. 11. Piping to the female thread type When mounting a fitting to the screw-in stud (female thread), hold the width across flats with an appropriate size wrench.
Warning Pilot port piping 12(P1) and 10(P2) piping should be as follows according to the model Standard () If the pilot air is not supplied, the valve position will not be held. Pressurize Port 12 (P1 ) or Port 10 (P2) when using the product. Vacuum pilot Installing a silencer to the exhaust port and the bleed port is recommended for noise reduction and for dust entry prevention.
Related Products Ambient and fluid temperature (C) Weight (g) Note) Bracket assembly Dust bag assembly 417 (436) ZH-BK1-20-A ZH-DB1-20-A 929 (990) ZH-BK1-30-A ZH-DB1-30-A 1847 (1966) ZH-BK1-40-A ZH-DB1-40-A 92 (101) ZH-BK1-10-A ZH-DB1-10-A Note) ( ): Weight including the bracket Flow Rate Characteristics ZH10-X185 ZH20-X185 ---7 ---7 1,800 800 Suction flow rate [L/min (ANR)] Note 1) Air consumption
e 00 10 20 30 40 50 60 70 80 90 100 110 Vacuum pressure 50 kPa (qwe) = Suction flow (Q1) 31 l/min (ANR).
Recommended flow rate Note) (l/min (ANR)) Mass (g) Internal capacity (cm3) 1.7 ZA Model IN side, OUT side 2 3.2 4 4 6 6 8 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" ZFC050-02 ZFC050-23 ZFC050-04 ZFC100-04 ZFC100-06 ZFC200-06 ZFC200-08 ZFC051-01 ZFC051-03 ZFC101-03 ZFC101-07 ZFC201-07 ZFC201-09 2 7 10 10 20 30 50 7 10 10 20 30 50 4.9 ZX 1.7 4.3 IN/OUT straight piping Metric size ZR Easy installation
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 Flow
-26-B) (ZS-26-01) ZS-26-01 1 (ZS-26-B) 190 2,1/41/2 72 2, , -15No.PF-OMN0011CN-C , 1 DC() 2 N.C.
MPa Inlet pressure : 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) 20 10 11,12,13 12 1000 10,11 08,09 10 15 8 500 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 548
03, 04 100 200 01, 23 100 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations AS4201F, AS4211F AS4301F, AS4311F AS3201F, AS3211F AS3301F, AS3311F 10, 11, 12 12, 13, 16 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 1500 1000 08, 09 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 06, 07 1000 500 500 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations
Side ported type is approximately 10% smaller. Note 3) Note 4) Note 4) Note 2) Based on JISB8375-1981 (Values for supply pressure of 0.5MPa with light/surge voltage suppressor. This will change depending on pressure and air quality.)
Model Description AMR3000 AMR4000 AMR5000 AMR6000 Bracket 13576 13556 13587 13568 G36-10-l01 G46-10-l02 Gauge (5) 1.0MPa Accessories (Options)/Part No.
Temperature characteristics (25C reference) 2%F.S. (0 to 50C) 3%F.S. (10 to 60C) 3% F.S. (0 to 50C) 4% F.S. (10 to 60C) 5% F.S. (10 to 60C) Accuracy Enclosure IP65 Withstand voltage 500 VAC for 1 minute between terminals and housing Insulation resistance 100 M or more (500 VDC measured via megohmmeter) between terminals and housing Operating temperature range Operating: 10 to 60C, Stored:
Temperature characteristics (25C reference) 2%F.S. (0 to 50C) 3%F.S. (10 to 60C) 3% F.S. (0 to 50C) 4% F.S. (10 to 60C) 5% F.S. (10 to 60C) Accuracy Enclosure IP65 Withstand voltage 500 VAC for 1 minute between terminals and housing Insulation resistance 100 M or more (500 VDC measured via megohmmeter) between terminals and housing Operating temperature range Operating: 10 to 60C, Stored:
Loop through current between power connector 16 A or less (EX245-FPS1/2) 10 A or less (EX245-FPS3) OFF 3 2 US2 [US3, US4 .. etc] is below the permissible level but above the dropout level (17 to 21.6 VDC). Flash Operating voltage 24 VDC +20%/-15%, Class 2 1 ON US2 [US3, US4 .. etc] is present (> approx. 22.8 VDC).
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2015 SMC Corporation All Rights Reserved EX-OMS0018
If the total lifting height is required instead of the discharge pressure, a discharge pressure of 0.1 MPa corresponds to a total lift of 10 m. Selection procedures: 1. First mark the intersection point for a discharge rate of 27 L/min and a discharge pressure of 0.25 MPa. 2. Find the pilot air pressure for the marked point.
If the total lifting height is required instead of the discharge pressure, a discharge pressure of 0.1 MPa corresponds to a total lift of 10 m. Selection procedures: 1. First mark the intersection point for a discharge rate of 15 L/min and a discharge pressure of 0.14 MPa. 2. Find the pilot air pressure for the marked point.