List of output mode Do not operate the product outside of the specifications. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Panel Measurement mode Hysteresis mode Mounting screws Press the button for 2 s or longer Switch output Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.
Do not disassemble, modify (including change of printed circuit board) or repair. An injury or failure can result. 1 s. after This function is to display error location and content when a problem or an error occurs. All indications Instantaneous value indicatio Error Name Error Display Error Type Troubleshooting Method Do not operate outside of the specification.
Do not touch the leakage of fluid without care. If the fluid has high temperature or is chemical, the contact could result in burn and other injuries. 3) Disassembly Do not disassemble the pump. Caution 1) Quality of supplied air Mount the filter with filtration of approx. 0.01.
Do not hold the bellows. Be sure to only hold the valve during reassembly. Pay great attention to mounting the bellow assembly. Otherwise, the bellows might be damaged. > (Note1) Only when disassembling the XLC, apply a 0.2 to 0.4 MPa of pressure to the closed side pilot port. Do not apply pressure to the XLA during disassembly. necessary. (Ensure there are no fibers or dust.)
Note1) To avoid the damage of O-ring and adjustment part, do not turn bypass valve adjusting bolt(13) farther than the point where turning is stopped at both ends. Note2) Do not apply pressure to the operation port during adjustment. Note3) Bypass valve is fully open at ex-factory.
Warning Environment (1) Do not use in environment where the product is exposed to corrosive gas, chemicals, salt water, water or steam. (2) Do not operate the product in a location where it is subject to strong vibration and/or shock. For vibration, it should be within IG 60Hz. -6- 6. Maintenance !
Mounting of fitting assembly Fitting assembly Clip Clip 11 - Caution Environment (1)Do not use the product in an environment where the product is directly exposed to corrosive gases, chemicals, salt water or steam. (2)Do not mount the product in a location where it is subject to strong vibrations and/or shocks. (3)Use this vacuum regulator in a location free from dirt since this product sucks
Do not drop nor apply impact during transportation or installation. These lead to cause precision failure of pressure. Do not install in areas of high humid or high temperature. Or pressure gauge may malfunction. Adjustment WARNING Adjust the pressure adjusting handle ensuring correct inlet pressure and outlet pressure. Excessive rotation may cause damage to internal parts.
Caution Food zone Not installable Do not use air grippers in a food-related environment. Splash zone Installable
T-slots l Model Bolt Max. tightening torque Nm Max. screw-in depth (l mm) LXP M5 x 0.8 7.4 8.5 Use bolts at least 0.5mm shorter than the maximum screw-in depth, so they do not touch the body.
Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 2. When equipment is to be removed, confirm the safety process as mentioned above.
Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 2. When equipment is to be removed, confirm the safety process as mentioned above.
ZSM PFl Piping IFl Caution qPiping materials Do not mount any equipment or fittings between the switch body and the detection nozzle in order to avoid leaks and pressure drops. Do not use one-touch fittings in applications where these fittings might be exposed to liquid being sprayed onto them.
Tidy Un-friendly What do you think to the manual presentation? ! ! ! Yes Not too bad Unusable Are the explanations understandable? Which explanation was most difcult to understand: . . ! ! Are there any diagrams which are not clear? Yes No If so,which:. ! ! ! What do you think to the manual layout?
The pressure sensors do not have an explosion proof rating. Never use pressure sensors in the presence of flammable or explosive gases.
Do not drop, dent, or allow excessive impact to cylinder during handling. 5, Keep at least 20mm away from each other when 2 or more cylinders with high magnetic field resistance auto 3. switch are mounted in parallel. up, although the auto switch will function. Do not exceed specified current or the LED might be damaged and not functjon.
MXS 6 MXS 8 MXS12 MXS16 MXS20 MXS25 4 5 5.5 6 10 13 0.9 0.9 2.1 4.4 4.4 7.4 M3 X 0.5 M3 X 0.5 M4 X 0.7 M5 X 0.8 M5 X 0.8 M6 X 1 Bottom screw Do not rotate Piston rod Precautions for Adjuster Option Stroke adjuster Do not damage. Caution eShock absorber is considered a consumable component. When energy absorption is decreased, replace it.
Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
The condition of the lock monitor and the detection signal from the lock unit auto switch do not directly confirm the locking condition at the piston rod, but confirm this indirectly from the position of the brake piston.