Do not operate Series CS1 at twice the output. CJ1 CJP Applicable Series CJ2 Series Vol. no.
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity. The VQ20/30's long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Manifold for VQ20/30 pilot operated valve
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity. The VQ20/30's long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Manifold for VQ20/30 pilot operated valve
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity. The VQ20/30's long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Manifold for VQ20/30 pilot operated valve
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. 3 Branch port (COM A to D) 4 Branch port A (COM A) 128 inputs/128 outputs Number of points Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
IO-Link DI DO StandardIO StandardIO 2 0x00 . 9-4 X0 X1 X2 X3 IO-Link 1 2 3 4 IO-Link 2 (I/Q) Bit 1 Bit 3 Bit 5 Bit 7 EX245-LA1 (EX245-LB1 0) 4 (C/Q) Bit 0 Bit 2 Bit 4 Bit 6 DO 2 4 (C/Q) Bit 0 Bit 2 Bit 4 Bit 6 DI() 9.5.
Refer to the SMC website (URL http://www.smcworld.com) to obtain more detailed information about troubleshooting. 3 Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Branch port (COM A to D) 8 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
DO (n+1) 0 V DO (n) FE / Shield N.C.
An injury or failure can result. 3 Display LED LED display to indicate the input unit status. 128 inputs/128 outputs Number of points Sensor connector Connector for sensor. 4 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. No.
Set up the output points using the internal switches. 3 Display and switch setting cover Switch for 16/32 outputs 128 inputs/128 outputs Number of points Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
List of output mode Do not operate the product outside of the specifications. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Panel Measurement mode Hysteresis mode Mounting screws Press the button for 2 s or longer Switch output Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.
Do not disassemble, modify (including change of printed circuit board) or repair. An injury or failure can result. 1 s. after This function is to display error location and content when a problem or an error occurs. All indications Instantaneous value indicatio Error Name Error Display Error Type Troubleshooting Method Do not operate outside of the specification.
Do not touch the leakage of fluid without care. If the fluid has high temperature or is chemical, the contact could result in burn and other injuries. 3) Disassembly Do not disassemble the pump. Caution 1) Quality of supplied air Mount the filter with filtration of approx. 0.01.
Do not hold the bellows. Be sure to only hold the valve during reassembly. Pay great attention to mounting the bellow assembly. Otherwise, the bellows might be damaged. > (Note1) Only when disassembling the XLC, apply a 0.2 to 0.4 MPa of pressure to the closed side pilot port. Do not apply pressure to the XLA during disassembly. necessary. (Ensure there are no fibers or dust.)
Note1) To avoid the damage of O-ring and adjustment part, do not turn bypass valve adjusting bolt(13) farther than the point where turning is stopped at both ends. Note2) Do not apply pressure to the operation port during adjustment. Note3) Bypass valve is fully open at ex-factory.
Warning Environment (1) Do not use in environment where the product is exposed to corrosive gas, chemicals, salt water, water or steam. (2) Do not operate the product in a location where it is subject to strong vibration and/or shock. For vibration, it should be within IG 60Hz. -6- 6. Maintenance !
Mounting of fitting assembly Fitting assembly Clip Clip 11 - Caution Environment (1)Do not use the product in an environment where the product is directly exposed to corrosive gases, chemicals, salt water or steam. (2)Do not mount the product in a location where it is subject to strong vibrations and/or shocks. (3)Use this vacuum regulator in a location free from dirt since this product sucks
Do not drop nor apply impact during transportation or installation. These lead to cause precision failure of pressure. Do not install in areas of high humid or high temperature. Or pressure gauge may malfunction. Adjustment WARNING Adjust the pressure adjusting handle ensuring correct inlet pressure and outlet pressure. Excessive rotation may cause damage to internal parts.
Caution Food zone Not installable Do not use air grippers in a food-related environment. Splash zone Installable