The amount of air requirement of rotary actuator = 0.06 x V x (P/0.1)/t l/min(ANR) V : Inner volume = cm3 P : Absolute pressure = {Operating pressure (MPa) + 0.1} t : Operating time = s CRB2 CRBU2 CRB1 Calculate the required air volume separately for the linear motion part and the rotary motion part.
P-80 (YG) 2nd printing June, 2002 D-DAD P-80 (YG) This catalog is printed on recycled paper with concern for the global environment.
F T n t kg RS H A Me 2 2 2 E 2 2 E 2 2 E 2 2 E 2 E m = 20 kg = 0.7 m/s d = 40 mm p = 0.5 MPa n = 20 cycle/min t = 25C rad/s 2.
(Plug) A + Stroke E B + Stroke FA FB C + Stroke PA + Stroke GB PB Q 2-Rc P G J K S XA H7 depth XL IE XA H7 depth XL T-slot dimensions Note 1) The intermediate strokes other than the standard strokes at left are manufactured by means of installing a spacer.
SMC'S new AC-A series of modular type F.R.L. unit is available in five sizes and is interchangeable with the existing modular AC line. The pressure drop across the regulator has been reduced creating a more efficient unit with a maximum set pressure of 100 psi. The element and bowl on the AW and AF series is now one-piece, making element replacement easier. Required maintenance space has
SMC'S new AC-A series of modular type F.R.L. unit is available in five sizes and is interchangeable with the existing modular AC line. The pressure drop across the regulator has been reduced creating a more efficient unit with a maximum set pressure of 100 psi. The element and bowl on the AW and AF series is now one-piece, making element replacement easier. Required maintenance space has
SMC'S new AC-B series of modular type F.R.L. unit is available in six basic sizes and is interchangeable with the existing modular AC line. The AC-B series has a maximum set pressure of 125 psi and offers embedded gauge and pressure switch options not found in the AC-A. The element and bowl on the AF series is now one-piece, making element replacement easier. Required maintenance space has
The CK1 series is a clamp cylinder available in two styles of clevis widths *. It is a non-lube, compact, lightweight cylinder with a built-in speed controller. Gaiters are unnecessary because a heavy-duty coil scraper is provided as a countermeasure against spatters. The CK1 is available in 3 bore sizes with stroke lengths up to 150mm. Options include rod attachments and auto-switch capabilities.Two
The CK1 series is a clamp cylinder available in two styles of clevis widths *. It is a non-lube, compact, lightweight cylinder with a built-in speed controller. Gaiters are unnecessary because a heavy-duty coil scraper is provided as a countermeasure against spatters. The CK1 is available in 3 bore sizes with stroke lengths up to 150mm. Options include rod attachments and auto-switch capabilities.Two
Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *,
Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *,
Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *,
Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, CLAMP, JPN SPL, CLAMP CYLINDER
P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4x20) with washer, 1 pc. P tight screw (4 x 14), 2 pcs. (3)Intermediate support bracket EX600-ZMB1: For direct mounting Enclosed parts: Round head screw (M4 x 5), 2 pcs.
P tithe screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc. P tithe screw (4 x 14), 2 pcs. (3) Intermediate support bracket EX600-ZMB1for direct mounting Enclosed parts: Round head screw (M4 x 5), 2 pcs.
P Registration of the PID (Product ID) of the Wireless Remote unit to be connected to the Wireless Base unit. Registration occurs at the initial setting, then wireless system will activate. Paring PID Abbreviation of Product ID. A 32 bit digit sequence which is assigned to identify the wireless unit (Base/Remote unit). PLC Abbreviation of Programmable Logic Controller.
P Registration of the PID (Product ID) of the wireless slave unit to be connected to the wireless master unit. Registration occurs at the initial setting, then wireless system will activate. Paring PID Abbreviation of Product ID. A 32 bit digit sequence which is assigned to identify the wireless unit (master/slave unit). PLC Abbreviation of Programmable Logic Controller.
P Registration of the PID (Product ID) of the wireless slave unit to be connected to the wireless master unit. Registration occurs at the initial setting, then wireless system will activate. Paring PID Abbreviation of Product ID. A 32 bit digit sequence which is assigned to identify the wireless unit (master/slave unit). PLC Abbreviation of Programmable Logic Controller.
P tithe screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc. P tithe screw (4 x 14), 2 pcs. (3) Intermediate support bracket EX600-ZMB1for direct mounting Enclosed parts: Round head screw (M4 x 5), 2 pcs.