: °C, Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
4 60 PSI (4kg|/cm') 6 90 PSI (6kglicm") lnput Current 0-4-20mADC(standard) . l 1 5 m A D C ' 2 2 1 0 m A D C ' 3 5 2 5 m A D C *4 10 50 mADC ' Special Order o ,,' Ogeration'/ Construction Model MmOO(Lever type) Single acting, Normal operation When the input current increass, the armature witt be subjected to a clockwise torque, pushing the flapper lever to the teft.
sResistanceConnectionMaterialWeightPF2A200/201PF2A510- -10.5 to 10.5 l/min0.5 to 10.5 l/min0.1 l/min0.1 l/pulseReal-time flow rateAccumulated flow0 to 999999 l, 0 to 999999 ft3 x 10-224 VDC (ripple ?
sResistanceConnectionMaterialWeightPF2A200/201PF2A510- -10.5 to 10.5 l/min0.5 to 10.5 l/min0.1 l/min0.1 l/pulseReal-time flow rateAccumulated flow0 to 999999 l, 0 to 999999 ft3 x 10-224 VDC (ripple ?
Stations: 10 (10 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.
IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 10 (10 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 10 (10 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 10 (10 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
sResistanceConnectionMaterialWeightPF2A200/201PF2A510- -10.5 to 10.5 l/min0.5 to 10.5 l/min0.1 l/min0.1 l/pulseReal-time flow rateAccumulated flow0 to 999999 l, 0 to 999999 ft3 x 10-224 VDC (ripple ?
sResponse timeHysteresisPower supply voltageResistancePF2A710Air, Nitrogen0.5 to 10.5 l/min0.5 to 10.5 l/min1 to 10 l/min0.1 l/min0.1 l/pulseReal-time flow rateAccumulated flow0 to 50C?5% F.S. or less?1% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)150 mA or less250 g1/8, 1/4Heater type3-digit, 7-segment LED?