SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-V-P-N02L-WA3"

Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø6; Vacuum (V) Port: ø12, Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 1 (100 VAC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: D (Push-turn Locking

Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø6; Vacuum (V) Port: ø12, Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: D (Push-turn Locking

Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø6; Vacuum (V) Port: ø12, Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push

Supply(P),Vacuum(V), One-touch Fitting: N (Supply (P) Port: ø1/4"; Vacuum (V) Port: ø1/2"), Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LN (L Plug Vertical Connector w/o Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking

Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø6; Vacuum (V) Port: ø12, Exhaust Type: PN (1/2-14NPT Port Exhaust), Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override:

Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø6; Vacuum (V) Port: ø12, Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm), Light/Surge Voltage Suppressor: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking

Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø6; Vacuum (V) Port: ø12, Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LN (L Plug Vertical Connector w/o Lead Wire), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type

Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø6; Vacuum (V) Port: ø12, Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: MN (M Plug Horizontal Connector w/o Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push

Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø6; Vacuum (V) Port: ø12, Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)0.8 to 5 V ?2.5% F.S.?

The ISE80 series is a digital pressure switch designed to measure fluids such as tap water, hydraulic fluid, silicon oil, lubricant, fluorocarbon, argon, ammonia, carbon dioxide, air-containing drainage and nitrogen.? Some of the features include 2-color indication, select from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)0.6 to 5 V ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)1 to 5 V ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)1 to 5 V ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)1 to 5 V ?2.5% F.S.?

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KD, ZSE40/50/60 1/4 PORTED, 0.96058 lb

The ISE80 series is a digital pressure switch designed to measure fluids such as tap water, hydraulic fluid, silicon oil, lubricant, fluorocarbon, argon, ammonia, carbon dioxide, air-containing drainage and nitrogen.? Some of the features include 2-color indication, select from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KD, ZSE40/50/60 1/4 PORTED, 0.35825 lb

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1)

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1)