Model: 22, Port Size: 2 (Rc1/4), Thread Type: T (NPTF), Base/Seal Material: CF (Brass, FKM Seal), Suffix: Standard, Number of Manifolds: 10 Stations
Body Size: 50, Thread: Rc, Port: 10 (1), Option: DG (D + G), Attachment: STV (S + T + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 60, Thread: N (NPT), Port: 10 (1), Option: Standard, Attachment: ST (S + T), Semi-Standard 1: Standard, Semi-Standard 2: RZ (R + Z)
Body Size: 50, Thread: Rc, Port: 10 (1), Option: DE (D + E), Attachment: STV (S + T + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Model: 21, Port Size: 2 (Rc1/4), Thread Type: T (NPTF), Base/Seal Material: C (Brass, NBR Seal), Suffix: Standard, Number of Manifolds: 10 Stations
Model: 22, Port Size: 1 (Rc1/8), Thread Type: T (NPTF), Base/Seal Material: CF (Brass, FKM Seal), Suffix: Standard, Number of Manifolds: 10 Stations
Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (1), Thread: T (NPTF)
Setting Type: Adjustable Type, Handle, Set Pressure: 0.02 to 0.5MPa, Port Size: 1/4 PT, Accessory: None, Suffix: T [High Temperature (-10 to 100°C)]
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: C (Locking Lever Style), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: C (Locking Lever Style), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: T (NPTF)
Function: 4 (3 Position Exhaust Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: A (Non-locking Push Extended Style), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)