AS131FM-M5-23 AS131FM-M5-04 AS131FM-M5-06 AS231FM-01-23 AS231FM-01-04 AS231FM-01-06 AS231FM-01-08 AS231FM-02-04 AS231FM-02-06 AS231FM-02-08 AS231FM-02-10 3.2 19.8 8.4 17.5 28.7 12.7 M5 x 0.8 8 8 4 20.3 33.8 28.8 30.1 25.1 9.3 9.6 9.3 10.8 6 21.4 20.6 31.8 13.5 11.6 3.2 24.4 8.4 17 17.5 30.9 12.7 9.3 13.1 4 24.9 9.3 35.2 30.2 32.1 27.1 12 R 1/8 14.2 18 22.9 36.3 13.5 10.9 6 14 26.9 11.6 21
F.O.F. 3.5 mm 2.0 mm 1.5 mm 18 N 5 x 18 2 x 3.2 mounting hole Roller plunger VZM550-01-06 VZM550-01-06S Panel mounting hole 12 (Polyacetal or hard steel roller) M14 x 1 Min. 2.5 Max. 9.5 Hexagon nut thick 8, across flats 22 M5 x 0.8 (Pilot exhaust port) Symbol (B) 2 (A) 4 12 14 3 (R2) 1 (P) 5 (R1) 0.5 MPa supply T.T. O.T. P.T.
Flow Direction Symbols on Body Meter-out type Meter-in type Symbol JIS Symbol 15-9-67 Series ASD-FM How to Order ASD 3 3 0 F M 01 06 S With seal M5 and U10/32 types, as they are not available with seal. Body size 2 3 4 M5 standard 1/8 standard 1/4 standard Type Applicable tubing O.D.
Model Description AL1000 AL2000 AL3000 AL4000 AL4000-06 AL5000 AL6000 B240A B340A B440A B540A B640A B640A Bracket assembly (1) Note 1) With bracket mounting screw (2 pcs.)
Set pressure range [MPa] 0.1 to 1.7 Ambient and fluid temperature [C] 5 to 60 (with no freezing) Applicable Model Applicable Model Model AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Model AR20-B AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Port size 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 r BG AR B B X430 30 03 BG q 30 AR
area (mm2) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG AS431FG Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 12, 13 10, 11 10, 11, 12 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm2) Effective area (mm2) 08, 09 06, 07 Number of needle rotations Number of needle rotations 15-9-44 3 Speed
-L) 68 2.8 depth 6.2 PF2M711/721-N7(-L) 64.6 2.8 depth 6.2 -99No.PF-OMW0007-E PF2M#L-C4/C6/C8/N7(-L) (mm) Model A C P PF2M701/702/705/710L-C4(-L) 84.4 7.6 2.8 depth 8.4 PF2M701/702/705/710/725/750L-C6(-L) 84.4 8 2.8 depth 8.4 PF2M725/750L-N7(-L) 84.4 11.8 2.8 depth 8.4 PF2M711/721L-C8(-L) 88 12 2.8 depth 6.2 PF2M711/721L-N7(-L) 88 10.3 2.8 depth 6.2 -100No.PF-OMW0007-E PF2M7#-#1/2(-L) (mm
AS121F-M5-05 3/16" M5 x 0.8 M5 x 0.8 11.4 21.3 26.1 7 16.5 13.5 11.7 22.9 11.6 18.1 6 AS121F-U10/32-06 AS121F-U10/32-05 3/16" 10-32UNF 10-32UNF 8 11.7 28.6 25.8 22.2 25 9.6 AS221F-01-23 AS2 1F-M5-07 20.4 16 9.3 27.5 3.2 1/4" M5 x 0.8 18.3 23.1 12 12.7 7 13.5 AS121F-U10/32-07 AS221F-01-04 9.3 27.5 20.4 4 1/4" 10-32UNF 14.3 17 AS221F-01-01 AS221F-01-06 27.5 27.5 6 20.4 11.6 20.4 36.1 32.1
ZH05DA06 06 06 One-touch One-touch One-touch 06 01 06 One-touch Screw-in One-touch 01 01 01 Screw-in Screw-in Screw-in ZH05DA07 07 07 One-touch One-touch One-touch 07 N01 07 One-touch Screw-in One-touch N01 N01 N01 Screw-in Screw-in Screw-in ZH07DA06 06 06 One-touch One-touch One-touch 06 01 06 One-touch Screw-in One-touch 01 01 01 Screw-in Screw-in Screw-in ZH07DA07 07
SUP port EHX I/O Cylinder port 2, 4 (A, B) 1, 3 (P, R) Serial unit: EX240 25-pin 26-pin 20-pin Conforms to IP67 Conforms to IP67 C3 (for 3.2) C4 (for 4) C6 (for 6) M5 (M5 thread) C8 (for 8) N9 (5/16") N1 (1/8") N3 (5/32") N7 (1/4") C4 (for 4) C6 (for 6) C8 (for 8) C10 (for 10) N3 (5/32") N7 (1/4") N9 (5/16") N11 (3/8") C8 (for 8) C10 (for 10) C12 (for 12) Rc 1/2 N7 (1/4") N9 (5
AS121FM-M5-23 AS121FM-M5-04 AS121FM-M5-06 AS221FM-01-23 AS221FM-01-04 AS221FM-01-06 AS221FM-01-08 AS221FM-02-04 AS221FM-02-06 AS221FM-02-08 AS221FM-02-10 3.2 4 6 3.2 4 6 8 4 6 8 10 22.1 22.1 22.9 27.5 27.5 27.5 32.4 34.4 34.4 36.4 43.2 8.4 9.3 11.6 9.3 9.3 11.6 15.2 10.4 12.8 15.2 18.5 17.3 17.3 18.1 20.4 20.4 20.4 25.3 25.2 25.2 27.2 33.9 12.7 12.3 7 28.8 25.1 30.1 9.6 33.8 M5 x 0.8 8 13.5
AR-OMX0055-B PRODUCT NAME Regulator MODEL / Series / Product Number AR20(K)-(F,N)01(F,N)02(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,R,Y,Z,ZA)-D AR30(K)-(F,N)02(F,N)03(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,R,Y,Z,ZA)-D AR40(K)-(F,N)02(F,N)04(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,R,Y,Z,ZA)-D AR40(K)-(F,N)06(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,R,Y,Z,ZA)-D AR50(K)-(F,N)06(F,N)10(B,E,E1,E2,E3,E4,G,M)(-1,N,R,Y,Z,ZA)-D AR60(K)-(
)-A AVA5000-(F,N)06~10(B,G,S)(-R,Z)-A AVL2000-(F,N)02(B,G,S)-(1~6)(D,Y,DO,YO,WO)(Z)(-R,Z)-A AVL3000-(F,N)02(B,G,S)-(1~6)(D,Y,DO,YO,WO)(Z)(-R,Z)-A AVL4000-(F,N)02(B,G,S)-(1~6)(D,Y,DO,YO,WO)(Z)(-R,Z)-A AVL5000-(F,N)06~10(B,G,S)-(1~6)(D,Y,DO,YO,WO)(Z)(-R,Z)-A Contents Page 1.
How to Order 1F 06 D 200 AS Flow direction symbol on body Flat head screw driver adjustable type Body size 100 200 205 300 400 M5 standard Applicable tubing O.D. 1/8 standard Metric sizes 23 04 06 08 10 12 Inch sizes 1/4 standard 3.2 01 03 05 07 09 11 13 1/8 3/8 standard 4 5/32 1/2 standard 6 3/16 8 1/4 10 5/16 With One-touch fitting 12 3/8 1/2 Use 1/8 tubing.
PA PA PA PA PA IN IN PA IN RETURN IN RETURN IN RETURN IN 646 Valve for Water and Chemical Base Fluids VCC Series How to Order Manifold 02 VV CC1 G M 06 C4 04 With gate valve Passage number Gate valve and cleaning valve mountable number 2 port valve, Cleaning valve 2/3 port valves mixed mounting 2 M 02 04 06 Cleaning valve (2 port valve): 1 pc. + Gate valve: 1 pc.
ASD Model Meter-out type Rod and applicable tubing O.D. 4 10 8 6 Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 AS AS-FE KE
) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 1/2 3/4 1 1 1/4 1 1/2 2 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 2.7 2.7 2.7 5.1 5.1 5.0 10.3 10.3 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 56 56 56 76 76 76 101 101 71 71 71 104 104 104 129
M Weight (g) AS AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 7.8 8.9 11.0 15.2 18.5 8.9 11.0 15.2 18.5 11.0 15.2 18.5 20.9
AL10, 20 AL30, 40, 40-06 AL50, 60 1 8 Body Zinc die-cast Aluminum die-cast Platinum silver Housing Platinum silver Aluminum die-cast Replacement parts Part no. Material Description No.
Precautions FH100-06 to 24: Nominal filtration 10 m q Mounting Confirm IN and OUT before mounting.