Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in
/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Ported), Pilot: R (External Pilot), Specifications: Standard, Voltage: 2 (200VAC 50/60HZ), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: T (NPTF)
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 0°, Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 13 (ø1/2"), Seal: S (w/Sealant)
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 1(180°), Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 13 (ø1/2"), Seal: S (w/Sealant)
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 0°, Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 13 (ø1/2"), Seal: S (w/Sealant)
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 3 (270°), Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 13 (ø1/2"), Seal: S (w/Sealant)
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 0°, Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 13 (ø1/2")
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 1(180°), Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 13 (ø1/2")
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 1(180°), Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 13 (ø1/2"), Seal: S (w/Sealant)
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 0°, Thread: R, Port Size: 04 (1/2), Applicable Tubing O.D.: 13 (ø1/2"), Seal: S (w/Sealant)
Stations: 2 Stations, Port Size: 04 (Rc1/2), Electrical Entry Direction: D (D Side Entry), Cable Length: 2 (3.0m Cable), Option 1: None, Option 2: W (Dust Poof IP65 Rated)
ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/2 (15A)15VXZ2242-04--0.70.623.00.346.01.5850
ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/2 (15A)15VXZ2240-04--1.00.723.00.346.01.5760
Ejector stations Port & silencer position 1 station 01 Right side Left side Both sides R L S 10 stations (Max.) 10 Note) Left and right as viewed with the VAC port in front Thread type Common exhaust port size 1/2 3/4 ZZMA dedicated silencer (ZZM-SA) 04 06 S Rc NPTF G Nil T F When placing an order, include the single type ejector models to be manifolded together with the manifold part