ACTUATOR CABLE FOR ABS ENC, ELECTRIC ACTUATOR, A02, 999 lb
OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 Work piece Work piece Work piece size is size is size is correct ON ON correct ON ON correct ON ON (Conforman (Conforman (Conforman Judgement ce range) ce range) ce range) size is large ON OFF Work piece Work piece size is small ON OFF I.D. is small ON OFF size is small OFF ON Work piece Work piece size is large OFF ON I.D. is large OFF ON No work piece OFF OFF
(between lead wire and case) -10C to 60C CE marking Dimensions (mm) D-Y7BWL-900 M2.5 x 4l Slotted set screw Indicator light Using flexible cable as standard spec. The optimum operating position can be determined by the color of the light.
(with no condensation) Withstand voltage 1000 VAC for 1 min. between whole charging part and case 2 M or more (500 VDC Mega) between whole charging part and case Insulation resistance Vibration resistance 10 to 150 Hz with a 0.7 mm amplitude or 50 m/s2 in each X, Y, Z direction for 2 hrs (De-energized) Impact resistance 150 m/s2 in each X, Y, Z direction, 3 times (De-energized) Standard CE
3 Port Pilot Solenoid Valve 10-SYJ300 Note) CE-compliant: For DC only.
4/5 Port Solenoid Valve 10-SYJ3000 How to Order Note) CE-compliant: For DC only.
External pilot How to Order Pilot Valve Assembly (OUT) 2 (OUT) 2 00 VT3113 G 1 1 (IN) 3 (EXH) X (PA) 1 (IN) 3 (EXH) X (PA) Electrical entry CE-compliant Coil rated voltage Q CE-compliant Note) Nil TL D T G Grommet Conduit terminal DIN terminal Conduit terminal with indicator light N.C.
Nil CE-compliant Q Q Rated voltage CE-compliant: Electrical entry is applicable only for the DIN terminal. 1 2 100 VAC, Hz 200 VAC, Hz 50 60 50 60 3 4 5 6 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 7 240 VAC, Hz 50 60 50 60 Port size 50 60 Note 1) CE-compliant: Electrical entry is applicable only for the DIN terminal.
Operating humidity range [%RH] 90 or less (No condensation) Weight [g] 350 (Except cable) [CE-compliant products] The EMC compliance of the teaching box was tested with the LECP6 series step motor controller (servo/24 VDC) and an applicable actuator.
Operating temperature range 41 to 122F (5 to 50C) Operating humidity range [%RH] 90 or less (No condensation) Weight [g] 350 (Except cable) Note) CE-compliance The EMC compliance of the teaching box was tested with the LECP6 series step motor controller (servo/24 VDC) and an applicable actuator.
CE marking Lead wires Oilproof flexible heavy-duty vinyl cord: 2.7 x 3.2 ellipse, 0.15 mm2, 2 cores (D-M9B(V)), 3 cores (D-M9N(V), D-M9P(V)) Note 1) Refer to page 13 for solid state auto switch common specifications. Note 2) Refer to page 13 for lead wire lengths.
Air Dryers Compliant to Overseas Standards Refrigerated Air Dryer Series IDFAE For use in Europe, Asia and Oceania EC Directive compliant (with CE marking) Power supply voltage: Single-phase 230 VAC (50 Hz) Refrigerant: R134a (HFC) R407C (HFC) Coefficient of destruction for ozone is zero.
Auto Switch Internal Circuit Standard CE marking Lead wires D-A90(V)/D-A93(V)Oilproof heavy-duty vinyl cord, 2.7, 0.18 mm2 x 2 cores (brown, blue), 0.5m D-A96(V)Oilproof heavy-duty vinyl cord, 2.7, 0.15 mm2 x 3 cores (brown, black, blue), 0.5 m D-A90, A90V Refer to page 207 for reed auto switch common specifications. Refer to page 207 for lead wire lengths.
/set 1 It is not possible to switch between models without valves and with valves. 2 Under the New Measurement Act, products with inHgpsi unit specifications are not permitted for use in Japan. 18 - Document No.ZL-OM01001-A How to Order Replacement Parts Supply valve/Release valve A CE/UKCA -compliant CE/UKCA -compliant CE/UKCA-compliant: For DC only.
CE mark is printed in the product label.
Operating temperature range 41 to 122F (5 to 50C) Operating humidity range [%RH] 90 or less (No condensation) Weight [g] 350 (Except cable) Note) CE-compliance The EMC compliance of the teaching box was tested with the LECP6 series step motor controller (servo/24 VDC) and an applicable actuator.
AN LECPA3 (Pulse input type) NPN AP PNP 11LEFS 1 For details about controller/driver and compatible motor, refer to the compatible controller/driver below. 2 Not applicable to CE. 3 When pulse signals are open collector, order the current limiting resistor (LEC-PA-R-) on page 596 separately. 11LEJS 25A!
No condensation) Applicable standard/directive CE/cUL Functions and Indications No.
The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in the system. Prevent foreign matter such as remnant of wires from entering the fieldbus system to avoid failure and malfunction. Mount the product in a place that is not exposed to vibration or impact. Otherwise failure or malfunction can result.
Accessories CE marking 1. The combination of Series LC6D and Series LX has been certified for CE marking. When using Series LX with CE marking, use it in combination with Series LC6D with CE marking. 2. The combination of Series LC6D and Series LX has been certified for EMC conformity.