SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20A-T-01-A1"

For vacuum/ compound pressure ISA2 ZSE30A 01 N M Option 3 Note) Calibration certificate Nil Y K T Note) Operation manual ISE35 Symbol Rated pressure range ZSE30A ZSE30AF 0 to 101 kPa 100 to 100 kPa PSE Piping specifications IS 01 Note) All texts in both English and Japanese.

Auto shift setting (PSE3 2(T)/3 5(T) models only) 1)Select the display mode of the pressure value at the time of auto shift operation. Either [AS (Auto shift)] or [ASO (Auto shift zero)] can be selected. AS (Auto shift): [AS] displays the differential pressure of the atmosphere and measurement pressure.

T Topology Connection configuration of the network -10No.EX-OMX1001 Installation and Wiring Installation Connect valve manifold to the SI unit.

Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-40No.EX-OMP0013-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [

IZ*-OMP0064 E P r o d u c t Ionizer Model/Series IZS4 Series Contents Safety Instructions . 1. How to Order . 1-1. Ionizer . 1-2. Accessories . 1-3. Option . 2. Installation . 2-1. Installation of ionizer . 2-1-1. Selection of piping port size . 2-1-2. Distance for installation . 2-1-3. Mounting and installation of the bracket . 2-2. Installation of the external sensor. 2-3.

Appendix F: Safety Characteristics Operation Output with Two Output with Outputs Two Channel Single Channel Channel Single Channel (only) Input (only) Input (only) Item Input Input SFF 99.98% 99.98% PFDAV (T) 1% of 10-3 1% of 10-2 Average Probability of Dangerous Failure PFH (T) 1% of 10-7 1% of10-6 Probability of dangerous failure per hour Achievable Safety Level SIL3 / PL e SIL2 / PL d

/PL / 16 108 No.EX##-OMY0006CN 22.F + + SFF 99.98% 99.98% PFDAV (T) Average Probability of -3 1% of 10 -2 1% of 10 Dangerous Failure PFH (T) Probability of dangerous -7 1% of10 -6 1% of 10 failure per hour Achievable Safety Level SIL3 / PL e SIL2 / PL d SIL3/PL e SIL2 PL d 109 No.EX##-OMY0006CN 23.GEX245-FPS EX245-FPS1/2/3 Input delay : tFilter + 2 ms tFilter = Parameterized filter

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: T (w

Red 4 Lock(+) B-1 Black 5 Lock(-) A-1 Brown 1 Sensor(+) B-3 Blue 2 Sensor(-) A-3 Actuator side Controller side 2 1 (14) (5.5) (1) B1 A1 (6.3) (17.7) 5 6 (2) (14.2) B6 A6 B1 (3) (10.2) A1 2 1 (18) A3 B3 (5.7) (4) 15 16 L (11) (30.7) 13 - (3) I/O Cable Pin No. # of wire Dot Dot Pin No. # of wire Dot Dot Color of Color of insulation mark color insulation mark color U Cable length (L) A1 1 Light

(b) IN0A3SVONA13 (a) 1k 6.8k PNP typeJXC6H(b) (a) COM-A2 (b) IN0A3SVONA13 2 Parallel I/O output circuit NPN typeJXC5HInside of the controller Outside OUT0B1 ALARMB13 10 COMA2 PNP typeJXC6HInside of the controller Outside COM+ 10 A1 OUT0B1 ALARMB13 28 No.JXC-OMY0002-A 6.3 The parallel I/O signal is detailed I/Ocable B1 A1 A1 A13 B1 B13 B13 A13 To the controller parallel IO connector The

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: Y (w/o Operation

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)