Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 16mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 30mm
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread
The ZCUK series is a non-rotating free mount cylinder for vacuum applications. The ZCUK was created by providing a vacuum passage in the rod of the CUK cylinder to enable a vacuum pad to be installed on the end of the rod. A guide is provided as standard equipment. Vacuum pads are available with pad diameters of ø2 to ø50. Cap or rod piping is available to the rod side. Series ZCUK is available
Bore Size: 25mm, Action: D (Double Acting), Body Option: Basic Style, Dust Cover: Chloroprene Rubber (CR), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: X78A (Dust Cover Caulking)
Magnet: D (Built-in), Mounting: B (Through Hole), Bore Size: 50mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 25mm, Body Option: Standard, Locking Direction: F (Forwarding Stroke Lock), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Clean Series: 11 (Vacuum Suction Type), Magnet: D (Built-in), Bore Size: 20mm, Stroke: 25mm, Rod End Thread: Female, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Series: 11 (Vacuum Suction Type), Magnet: D (Built-in), Bore Size: 25mm, Stroke: 25mm, Rod End Thread: Female, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 25 mm, Rod End Thread: B (Without Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø16 mm, Stroke: 25 mm, Rod End Thread: B (Without Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø6 mm, Stroke: 25 mm, Rod End Thread: B (Without Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in