Example) AR30-03BG-NR-X425 Symbol Body size Description 25 30 40 50 60 Body size Description Symbol Nil N F Thread type Rc NPT G 20 25 30 40 50 60 Nil N F Thread type Rc NPT G + 02 03 04 06 10 1/4 3/8 1/2 3/4 1 + 01 02 03 04 06 10 Port size 1/8 1/4 3/8 1/2 3/4 1 + Port size Nil B Note 2) Without mounting option With bracket With set nut (for panel fitting) H Mounting a + Note 1) Semi-standard
Screw-in Screw-in 05 07 0.5 mm 0.7 mm 06 08 10 12 16 01 02 03 04 6 8 10 12 16 Rc 1 8 Rc 1 4 Rc 3 8 Rc 1 2 10 1.0 mm 13 1.3 mm 15 1.5 mm 18 1.8 mm 20 2.0 mm Maximum vacuum pressure S L 88 kPa 48 kPa VAC. port size Note) Symbol Size Style One-touch One-touch One-touch One-touch Screw-in Screw-in Screw-in Screw-in SUP. port size Note) 06 10 12 16 01 02 03 04 6 10 12 16 Rc 1 8 Rc 1 4 Rc 3 8
sets) SJ SY U side Stations D D D D D SV SS5V1-W10S4VWD-05B-C6 1 set (manifold part no.)
Metric size Inch size 100 200 205 M5 standard 1/8 standard 1/4 standard 3.2 4 6 8 23 04 06 08 01 03 05 07 09 1/8" 5/32" 3/16" 1/4" 5/16" Use 1/8" tube.
BD1-08M BD1-10M D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G59F D-G5NTL D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G59F D-G5NTL BAF-06 BAF-08 BAF-10 BH2-040 BA5-050 BA-04 BA-05 BA-06 BA-08 BA-10 Note 1) Auto switch brackets are included in D-A3C/A44C/G39C/K39C types.
-04 FH540-06 FH540-08 FH540-10 FH540-12 10 3/8 3/8 10 FH541-04 FH541-06 FH541-08 FH541-10 FH541-12 FH541-16 15 (1/2B) 20 1/2 1/2 20 20 (3/4B) 20 (3/4B) 50 3/4 3/4 50 Max. 14 MPa Max. 3.5 MPa 25 (1B) 25 (1B) 80 1 1 80 FH341-10 FH341-12 FH341-16 32 (1 1/4B) 32 (1 1/4B) 120 1 1/4 1 1/4 120 40 (1 1/2B) 40 (1 1/2B) 160 1 1/2 1 1/2 160 50 (2B) 50 (2B) 260 260 FH440-03 FH440-04 FH440-
VX3 Valve type Material VXA 0 1 2 N.C. N.O. Double acting Body Applicable option Actuator section End plate PPS Diaphragm Port size Symbol Note 1 2 3 4 VN Symbol 01 02 01 02 02 03 03 04 04 06 10 Port size 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 Body class Stainless steel PTFE A 1 Note) Refer to Variations in the table below for valve type combinations.
ADDRESS 4632 4632 4632 1 1 1 9 9 9 PW LRUN ON POWER ALARM COMM Name of terminal block, LED Note Cable wiring 2 2 2 1 ON 8 8 8 O N 3 3 3 7 7 7 4632 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND x 10 x 1 1 2 3 4 5 6 7 8 OFF DG 24 V 0 V D G D G 0 V 24 V 24 V 0 V A B SG FG 0 V 24 V 24 V 0 V +24V 24G DA DB FG Description LED ON for SI unit power supply input Description LED Description LED POWER COMM
Metal Bowl Metal Bowl With Sight Glass NPT Threads Port Size Symbol 02 03 04 Accessories Symbol Nil B* C D H* Applicable Body Size 20 30 40 Port Size 1/4 3/8 1/2 Applicable Body Size All All 30, 40 30, 40 All Description None Mounting Bracket Float Auto Drain (N.C.)
100 200 205 Inch size M5 standard 1/8 standard 1/4 standard 3.2 23 04 06 08 01 03 05 07 09 1/8" 5/32" 3/16" 1/4" 5/16" 4 6 8 Use a 1/8" tube.
21.4 24.9 M L Q A D D O N M M Note 1) D is maximum diameter.
D !"# ! ! Coil insulation type # 9% ,* /) 3 ? $% % 33 1 ,) % % 1 ) ,, ) /) H B 7 !"# ! , & Ordering example VX021-001GB-01 !"# $ % & VX021-002DBT-04 ' ( !
Metric size Inch size 100 200 205 M5 standard 1/8 standard 1/4 standard 3.2 4 6 8 23 04 06 08 01 03 05 07 09 1/8" 5/32" 3/16" 1/4" 5/16" Use 1/8" tube.
no condensation) Polyurethane Shore D 57 Note 1) Consult SMC regarding other fluids.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2
D !"# ! ! Coil insulation type # 9% ,* /) 3 ? $% % 33 1 ,) % % 1 ) ,, ) /) H B 7 !"# ! , & Ordering example VX021-001GB-01 !"# $ % & VX021-002DBT-04 ' ( !
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-O021 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
(mm) M Effective area (mm 2) Weight (g) A L2 L1 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 DL04-01 15 3.5 23 DL04-02 17 19 4 10 23.5 19.6 10 30 DL06-01 25 17 Applicable tubing 19.6 10 23.5 DL06-02 16 19 31 14 6 9 12 DL06-03 22 53 26.5 24.5 21.6 22.6 24.5 25.8 24.5 29.4 29.6 30.3 29.4 91 Reference dimensions after R thread installation.
L ZY O L ZF G H F ZP K J SP ZCUK B C E D I A 2 x 4.5 AMJ AMV AEP HEP Related Equipment A B C D E F G H I J K L Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC051-01 ZFC051-03 58.5 12.75 12.75 2 3.2 4 33 25 10 10.5 10.5 12 8.5 13.75 58 12.5 12.5 1/8" 5/32" ZFC100-04 4 ZFC100-06 6 53.2 9.1 14.1 30 10 18 11.6 19.5 23 20 29 ZFC101-03 5/32" ZFC101-07 1/4" ZFC200-06 6 ZFC200-08 8 67 15.5 17.5 34 14 22