49 1/8 17 8 32 M12 x 1.75 11 depth 6.5 61 51 10 18 14 15 7 47 6.6 63 1/4 19.5 10 40 M16 x 2 14 depth 8.6 65 55 10 22.4 19 20 7 52 9 71 1/4 20.5 10 50 M20 x 2.5 17.5 depth 10.8 71 60 11 28 24 24 8 58 11 81 1/4 22 10 63 M27 x 3 20 depth 13 80 67 13 35.5 30 33 9 69 13 97 1/4 25.5 10 80 M30 x 3.5 23 depth 15.2 95 78 17 45 41 36 14 86 15 117 3/8 30 15 100 M39 x 4 26 depth 17.5 122 96 26 56 50
Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.
D-P4DWSC D-P4DWSE D-P4DWL D-P4DWZ BA8-032 Dimensions 25 28 5 6 12 3 x Rc 1/8 3 x Rc 1/8 9.5 20 4 Speed controller valve Cushion valve 4 32 12 4 45 45 M10 x 1.25 Max. 26.5 12 40 26 41.5 Width across flats 36 12 R12 12 +0.5 +0.2 Shaft: 10 0.040 d90.076 28 26 Hole: 10 +0.022 H8 0 41.2 38 5 20 34 + Stroke 70 + Stroke 55 137 + Stroke Double knuckle joint Single knuckle joint 10 +0.022 H8 0 3
OApplicable hole diameter of workpiece for 10 to 20 L Fine adjustment of the clamping height is possible with shims. (Order shim separately. Refer to page 543.)
BA8-032 MK2T CK1 CK1 Dimensions CLK2 CLKG 28 25 5 6 12 3 x Rc1/8 (Piping port) 3 x Rc1/8 (Piping port) CKQ CLKQ 20 4 9.5 Speed controller valve Cushion valve 4 32 CK CLK 12 4 45 45 M10 x 1.25 Max. 26.5 CKQ 12 40 26 41.5 12 Width across flats 36 R12 +0.5 +0.2 12 0.040 d9 0.076 Shaft: 10 Hole: 10 28 26 +0.022 H8 0 41.2 38 5 20 34 + Stroke 70 + Stroke 55 137 + Stroke Double knuckle joint Single
Width across flats 10 Width across flats 36 R12 0.040 0.076 +0.022 0 Shaft: 10d9 +0.5 +0.2 12 12 6 Hole: 10H8 102 + Stroke 55 26 41.2 169 + Stroke Unclamp side lock (F) 3-Rc 1/8 Unclamp side port 3-Rc 1/8 Clamp side port 25 60 34 + Stroke 20 Rear cushion valve 12 4 53 12 6 5 47 45 45 19 9.5 M10 x 1.25 12 40 26 26 10 Width across flats 10 R12 Width across flats 36 Shaft: 10d9 0.040 0.076
(Including band and screw) Operating Range Bore size (mm) Bore size (mm) Auto switch model Auto switch model 20 25 32 40 50 20 25 32 40 50 D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 D-B7/B80 BMA2 -025 BMA2 -032 BMA2 -040 BMA2 -050 BMA2 -020 10 8 10 9 10 D-B73C/B80C D-C7/C80 BA -32 BA -04 BA -05 BA -01 BA -02 10 8 10 9 10 D-C73C/C80C D-B5/B64 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 10 8
model Bore size (mm) 40 32 25 20 D-B7/B80 D-B73C/B80C D-C7/C80 D-C73C/C80C D-B5/B64 8 10 9 10 8 10 9 10 8 13 8 10 13 10 9 14 9 10 14 10 D-B59W D-G79/K79/K79C D-H7BAL D-H7/H7W/H7NF 4 4 4.5 5 7 8.5 9 10 D-H7C D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL 4 4 4.5 5 6 45 D-G59F D-G5NBL 5 35 5 40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.
model Bore size (mm) 40 32 25 20 D-B7/B80 D-B73C/B80C D-C7/C80 D-C73C/C80C D-B5/B64 8 10 9 10 8 10 9 10 8 13 8 10 13 10 9 14 9 10 14 10 D-B59W D-G79/K79/K79C D-H7BAL D-H7/H7W/H7NF 4 4 4.5 5 7 8.5 9 10 D-H7C D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL 4 4 4.5 5 6 45 D-G59F D-G5NBL 5 35 5 40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.
attachment MHT2-63DZ 2 x M12 x 1.75 thread depth 10 Mounting thread 25 60 104 90 4 x M10 x 1.5 thread depth 18 Mounting thread 24 45 60 11 4 x M12 x 1.75 thread depth 17 Mounting thread (Both sides) 10 10 Open 23 Closed 2 132 116 77 60 0.2 36 7 80 60 0.2 40 3.2 10 17 (169.2) 66 53.2 35 Rc (G , NPT ) 1 4 1 4 1 4 2 x M12 x 1.75 thread depth 10 Mounting thread Finger closing port Rc (G ,
: 201 to 300mm 80 40 50 50 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
Prevent the stoppage of rotating parts (pins, etc.) by applying grease. 10)Do not use the product until you have verified that the equipment can operate properly.
Cylinder specification Bore size (mm) 32 40 50 63 80 100 Action Double acting/single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Min. operating pressure 0.08MPa Without auto switch-10 to 70 Ambient and fluid (No freezing) temperatures With auto switch-10 to 60 Lubricant Not required (Non-lube) Piston speed 50 to 1,000mm/s * Stroke length tolerance [mm] Up to 500st+2.0
Base Mounted Wiring: 10 (Base Mounted Non Plug-in Individual Lead Wire Entry), Stations: 9 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 03 (3/8)
Base Mounted Wiring: 10 (Base Mounted Non Plug-in Individual Lead Wire Entry), Stations: 10 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 03 (3/8)
Base Mounted Wiring: 10 (Base Mounted Non Plug-in Individual Lead Wire Entry), Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 03 (3/8)
Base Mounted Wiring: 10 (Base Mounted Non Plug-in Individual Lead Wire Entry), Stations: 4 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 03 (3/8)
Base Mounted Wiring: 10 (Base Mounted Non Plug-in Individual Lead Wire Entry), Stations: 4 Stations, Passage: 2 (P and EA,EB: Common, Port A,B: Bottom), Port Size: 03 (3/8)
Base Mounted Wiring: 10 (Base Mounted Non Plug-in Individual Lead Wire Entry), Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 03 (3/8)
Base Mounted Wiring: 10 (Base Mounted Non Plug-in Individual Lead Wire Entry), Stations: 6 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 03 (3/8)