Model AMR3000 AMR4000 AMR5000 AMR6000 Model name 1 4 3 8 1 2 : E4-02 : E4-03 : E4-04 1 4 1 2 : E6-06 : E6-10 3 4 : E3-02 : E3-03 : E5-04 : E5-06 Adapter assembly (7) 3 8 3 4 1 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float type auto drain (AMR 100) (8) IS10-01 (0.4 MPa setting) Compact pressure switch 135510 135613 Elbow (R x Rc) (9) Note 5) in the gauge part number (e.g.
SO-03 SO-04 SO-05 NT-02 NT-03 NT-04 AC-NI-50 8 8 9 11 30 36.9 43.9 47.3 26 32 38 41 5 6 8 10 12.5 16.5 21.0 23 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 15.0 19.6 25.4 27.7 20 25 32 40 M22 x 1.5 M24 x 1.5 M30 x 1.5 M33 x 2.0 26 32 38 41 13 17 22 24 10 Series CHN Accessory Brackets (Optional) I-shaped single knuckle joint Bracket for clevis type Material: Cast iron 20: I-02 25
Microswitch OMRON D2VW-01 Gold plated contacts Bus Powered, no external power needed.
Y, Z directions 3limes each 12.6FS or lesis at 25'C 01: Rl/8. [.r5 x 0 8, Tl: NPT1/8, M5 x 0 8.
Y, Z directions 3limes each 12.6FS or lesis at 25'C 01: Rl/8. [.r5 x 0 8, Tl: NPT1/8, M5 x 0 8.
BA -02 BA -32 BA -04 BM2 -020 BM2 -025 BM2 -032 BM2 -040 BA -05 BA -06 BA -08 BA -10 BA01 BA02 BA32 BMA2-050 BMA2-063 BMA2 -020 BMA2 -025 BMA2 -032 BMA2 -040 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available.
BA -02 BA -32 BA -04 BM2 -020 BM2 -025 BM2 -032 BM2 -040 BA -05 BA -06 BA -08 BA -10 BA01 BA02 BA32 BMA2-050 BMA2-063 BMA2 -020 BMA2 -025 BMA2 -032 BMA2 -040 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available.
BA -02 BA -32 BA -04 BM2 -020 BM2 -025 BM2 -032 BM2 -040 BA -05 BA -06 BA -08 BA -10 BA01 BA02 BA32 BMA2-050 BMA2-063 BMA2 -020 BMA2 -025 BMA2 -032 BMA2 -040 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available.
A A1 MM U1 L1 RR1 A1 L1 E1 MM RR1 U1 0.4 0.2 + 0.2 + 0 0.2 0.4 0.2 0.4 10 12 16 20 +0.002 0 5 6.4 8 10 0.2 0.4 0.1 0.3 0.2 0.4 0.2 0.4 +0.002 0 5 6.5 8 10 #8-32UNC 10 12 16 20 12 16 20 25 10 12 16 20 14.6 16.6 21 25.6 RCS-01 RCS-015 RCS-02 RCS-025 RCD-01 RCD-015 RCD-02 RCD-025 21.5 32 34 41 6 6 6 8 16 25 25 30 #8-32UNC #8-32UNC #10-32UNF 1/4-28UNF 6.3 12 10.3 18 7 14 11.5 14
(mm) Rod Flange Symbol F GB B A AL B1 C D FT FX FD ZZ E GA H H2 H1 I J MM KA NA P S Bore size (mm) 20 25 32 40 50 63 80 100 12 15 15 20.5 26 26 32.5 32.5 14.5 17.5 17.5 23.5 29 29 35.5 35.5 8 10 12 14 18 18 22 26 12 14 18 25 30 32 40 50 5 6 6 8 11 11 13 16 79 85 87 93 121 121 151 152 40 44 53 61 76 92 104 128 13 17 17 19 27 27 32 41 14 16.5 20 26 32 38 50 60 2 2 2 2 2 2 3 3 28 32 38 46 58
2 stations Rc 1/4 1 8 Rc Nil F N Z NPTE 01 Rc C6 One-touch fitting for 6 4(A), 2(B) port G 20 20 stations 1(P) port Rc 1/8, C6 NPT B7 One-touch fitting for 1/4" Rc 1/4 How to Order Type 43 VV5Z3 05 43 1 C4 1(P), 3/5(R) port thread type 4(A), 2(B) port size Stations 02 2 stations 3/5(R) port Nil F N Z NPTE Rc C4 One-touch fitting for 4 Rc 1/8 G B3 One-touch fitting for 5/32" 20 20 stations
(Default) Spare Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 3 36 4. STARTUP 4.
one piece) E3 03 R S AMR 4 0 00 02 E 3 Auto drain Additional symbol Port size 1 None With auto drain 0 Flow direction: left to right MR unit Flow direction: right to left 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)
IDG60S to IDG100S IDG3 to IDG50 IDG3H to IDG50H IDG30L/ IDG50L Port size With separator regulator Symbol Bore Size 3 5 10 20 30 50 60 75 100 V IDG60 to IDG100 IDG60H to IDG100H IDG60L to IDG100L 01 1/8 02 1/4 IDG60S to IDG100S Note) Note) 03 3/8 04 1/2 Note 1) Specifications with element service indicator are also available. See the order made section on page 33.
IDG60S to IDG100S IDG3 to IDG50 IDG3H to IDG50H IDG30L, IDG50L Port size Symbol Bore Size V IDG60 to IDG100 IDG60H to IDG100H IDG60L to IDG100L 3 5 10 20 30 50 60 75 100 01 1/8 02 1/4 IDG60S to IDG100S Note) Note) 03 3/8 04 1/2 Note 1) Element service indicator is also available. Refer to Made to Order Specifications on page 14-19-48.
D-B5/B64 D-G5/K59 D-G5W/K59W (A set of band and screw) BA-02 BA-01 (A set of band and screw) BA-32 (A set of band and screw) BA-04 (A set of band and screw) BA-05 (A set of band and screw) BA-06 (A set of band and screw) BA-08 (A set of band and screw) BA-10 (A set of band and screw) Note) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform,
"-M" ( ) "-M" 13 SI kPaMPa 14 15 () 16 () / ( () ) -29No.PS-OMG0001CN-H OUT1 80mA OUT2 7F.S. 3 ( 4dights ) 1 -30No.PS-OMG0001CN-H PSE3 -100100 kPa 0-101 kPa 0100 kPa 01 MPa 0500 kPa 02 kPa 1 -101101 kPa 10-101 kPa -10100 kPa -0.11 MPa -50500 kPa -0.22 kPa 0.2 kPa 0.1 kPa 0.1 kPa 0.001 MPa 1 kPa 0.01 kPa DC1224 V10P-P10 50 mA() PSE30DC15 V(1 M) PSE31DC420mA100 ) 1 26.4V
BA -02 BA -32 CDLG1 BMA2 -020 BMA2 -025 BMA2 -032 BMA2 -040 BA -04 BMA2 -050 BA -05 BA -06 BA -08 BA -10 MGC RHC, MLGC, REC BA01 BA32 BA02 BMA2 -050 RSDG Mounting screw set (Stainless steel specification) Use the following mounting screw set (Set screw included.) according to the required operating conditions.
C Note 1. ## denotes any of numerals 00 to 16 and what it means is listed below. ## Description 00 Set to the test operation mode. 01 Station number 1 02 Station number 2 03 Station number 3 : : : : 62 Station number 62 63 Station number 63 64 Station number 64 Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number. 3. indicates the warning/
Positioning operation method of operation . 115 -2- 8.1 Point table method . 117 8.1.1 Positioning operation indication of the point table method (Example) . 117 8.2 Remote register method . 121 8.2.1 Positioning operation indication of the remote register method (Example) . 121 9.