SMC Corporation of America
Elite Part Number Search
Search Results "VV3P3-41-121-02N"

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 39 39 40 40 41 41 43 45 47 54 54 55 55 56 60 65 68 70 70 71 71 72 77 78 82 84 87 89 91 93 96 97 98 99 99 100 101 102 Series MSUB Rotary Table: Basic Type Vane Style Size: 1, 3, 7, 20 . How to Order . Specifications. Construction. Dimensions .

Data Symbol Specifications Anti-corrosive specifications for guide unit (N) -X42 Operating pressure (MPa) Bore size (mm) Rod size (mm) Operating direction Piston area (mm2) 0.7 0.6 0.5 0.4 0.3 0.2 71 61 51 40 30 20 101 R 4 8 53 45 38 30 23 15 75 L 158 136 113 90 68 45 226 R 6 12 119 102 85 68 51 34 170 L 281 241 201 161 121 80 402 R 8 16 211 181 151 121 91 60 302 L 440 377 314 251 188 126

Width across flats 13 Operating port Rc 1/8 (NPT 1/8, G 1/8) 8 x M5 x 0.8 thread depth 13 Note) A Operating direction 6H9 + 0.030 0 depth 5.5 (Insert) 7 (Hexagon socket head taper thread plug) 48 98 72 41 10 8 25 40 40 40 Y Y Operating port Rc 1/8 (NPT 1/8, G 1/8) 41 160 B Operating direction 6H9 + 0.030 0 depth 5.5 (Hexagon socket head taper thread plug) 10.5 Operating direction B A 9.5

Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Conditions Body ported Series CJ2 Series CM2 Series MB, CA1 T0425 x 1 m Tube bore x Length VQ0149-C4 Speed controller AS2001F-04 AN103-X233 Silencer Tube bore x Length T0604 x 1 m 30 41 VQ11 -C6 Speed controller AS3001F-06 Silencer AN103-X233 T0806 x 1 m Tube bore x Length VQ2149-C8 Speed controller AS3001F-08 Silencer AN200-KM8

Detailed information of units 41 3.4.1. Information tab 41 3.4.2. Details of I/O monitor tab 50 4. Setting Function 57 4.1. Edit TAG 57 4.2. Software Control 57 4.3. Forced output 60 4.3.1. Forced output conditions 60 4.3.2. Forced output procedure 60 4.3.3. Forced output release procedure 63 4.4. Export Settings 64 4.5. Import Settings 66 4.6. Reading of the initial value 67 4.7.

(A) 4 (A) 4 (B) 2 (B) 2 (Example) SS5YJA7-41-03-01 1 pc. SYJA7140 1 pc. SYJA7240 1 pc. SYJ7000-21-1A 1 pc. 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 3 position exhaust center 3 position closed center (A) 4 (A) 4 (B) 2 (B) 2 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) The asterisk denotes the symbol for assembly.

(1) Operation check by test drive . 41 (2) Operation check with the monitor . 41 5.4.1 Operation check by test drive. 41 (1) Operation check by test drive in easy mode . 41 (2) Operation check by test drive in normal mode . 43 5.4.2 Operation check with monitor . 45 (1) Operation check with monitor in easy mode . 45 (2) Operation check with monitor in normal mode . 46 6.

The switch may be damaged if a screw other than the one supplied, is used. 0.28( 8) 0.28( 8) 0.25( 7) Lead wire length in(m) 118(3 ) 1.45(41) 1.45(41) 1.34(38) 197(5 ) 2.40(68) 2.40(68) 2.22(63) Auto Switch Internal Circuit Unit: in Dimensions D-M9N, M9NV ( ): mm D-M9 Mounting screw M2.5 x 4l Slotted set screw Indicator light DC (+) Brown 0.10(2.6) Switch main circuit OUT Black 0.11 (2.7)

Fittings & Tubing Air Cylinders Rotary Actuators Operating port 2 x M5 x 0.8 41 6.3 16.5 20 8.5 13 Other dimensions are the same as basic type. 810 MXQ 1322Air Slide Table Dimensions: MXQ12L / Symmetric Type 1322Basic ZZ Z Note 1) If long bolts are used, they can touch the guide block and cause malfunction, etc.

5 25 113 60 C76 Mounting style (E) C85 C95 CP95 NCM NCA D-X 20Bore size (mm) d2 CK S5 K1 K2 l3 G1 l1 G2 EM G3 CA H6 R1 Data 32 11 10 38 51 10 21 18 26 31 32 10 6.6 7 8 40 11 12 41 54 10 24 22 28 35 36 11 6.6 9 10 50 15 12 50 65 12 33 30 32 45 45 12 9 11 12 63 15 16 52 67 14 37 35 40 50 50 15 9 11 12 80 18 16 66 86 18 47 40 50 60 63 15 11 12.5 14 100 18 20 11 76 96 20 55 13.5 50 60 70 71

For double vane style, rotation tolerance of 90 actuators will be for size 10 actuators only. 11-3-6 41 Series CRBU2 Rotary Actuator: Free Mount Type Vane Style Construction: 10, 15, 20, 30, 40 Single vane type Standard: CRBU2W10/15/20/30/40-S (3 female threads (one of them is indicated with ) spaced equally apart in 120 are not available for size 10.)

For double vane style, rotation tolerance of 90 actuators will be for size 10 actuators only. 11-3-6 41 Series CRBU2 Rotary Actuator: Free Mount Type Vane Style Construction: 10, 15, 20, 30, 40 Single vane type Standard: CRBU2W10/15/20/30/40-S (3 female threads (one of them is indicated with ) spaced equally apart in 120 are not available for size 10.)

5 25 113 60 C76 Mounting style (E) C85 C95 CP95 NCM NCA D-X 20Bore size (mm) d2 CK S5 K1 K2 l3 G1 l1 G2 EM G3 CA H6 R1 Data 32 11 10 38 51 10 21 18 26 31 32 10 6.6 7 8 40 11 12 41 54 10 24 22 28 35 36 11 6.6 9 10 50 15 12 50 65 12 33 30 32 45 45 12 9 11 12 63 15 16 52 67 14 37 35 40 50 50 15 9 11 12 80 18 16 66 86 18 47 40 50 60 63 15 11 12.5 14 100 18 20 11 76 96 20 55 13.5 50 60 70 71

.121 1TB Ver1.**.121 2TB Ver2.**.123 4 - LEC-T1 Series/ (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety JIS B 8370: JIS B

Refer to page 66 for part numbers. 37 41 Non-standard Motor 10mm/6mm lead Series LTF6 Motor Output Rolled Ball Screw 100W Horizontal Mount How to Order Motor/switch entry direction Stroke E LTF6 NF 1 G X10 Left entry Power supply voltage Motor specification Switch specifications Right entry Matsushita Electric Industrial Co., Ltd.

Exploded View: VQ1000-Plug Lead Unit (F, P, T, S kit) . 115 115 116 121 122 122 123 126 126 127 130 131 132 136 140 144 148 152 156 160 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 164 167 168 172 174 176 177 179 184 184 185 186 186 187 188 188 190 194 198 202

side trunnion: U (40) 51 35 25 32 0.7 64 DSeries CS1 only W Series C85: 20, 25 W 37 24 35 17 22 0.3 47 -X 100.0 T 27 18 26 12 16 0.5 35 2022 14 21 10 13 0.7 28 Foot: L Rod side flange: F Head side flange: G (100) (40) (40) (40) (40) (100) 0.3 Data Lateral load applied to the rod end fR (N) L (40) (40) (40) (40) (100) 89 0.5 W W W F 10.0 (40) (40) (40) 74 36 0.7 93 (40) 54 37 26 33 0.3 69 G 41

A0.2 D (mm) MGPM MGPL/A Hexagon socket head cap screw 50 56 72 82 98 106 130 142 180 210 Bore size (mm) A (mm) B (mm) C (mm) M4 x 0.7 M5 x 0.8 M5 x 0.8 M6 x 1.0 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 M12 x 1.75 M14 x 2.0 8 10 12 15 18 18 22 22 28 33 12 16 20 25 32 40 50 63 80 100 10 12 14 18 22 22 27 27 33 39 41 46 54 64 78 86 110 124 156 188 18 22 24 30 34 40 46 58 54 62 5.

Refer to page 204 regarding brake wiring. 600 a = 2000 a = 1000 400 a = 3000 a 200 L3 Mey 0 5 10 20 15 Transfer load m (kg) Refer to page 145 for deflection data. 40 41 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Standard Motor/Vertical Mount Specification Series

(Tolerance 30%) OUT() Blue(Black) 5.3-41 2 Color Indication Style Solid State Switch/Band Mounting D-H7NW/D-H7PW/D-H7BW Applicable Actuator Series Grommet Series Bore size (mm) The suitable operating point can be indicated with a green light.