<br>Note) The KK□ series S coupler cannot be used as a stop valve that requires zero leakage. Due to the specifications of the product, a certain amount of leakage is unavoidable.<br><br>
<br>Note 3) If the surge pressure is higher than the max. operating pressure, it may cause damage to the fitting or tube.<br><br>
<br><br>Meter-in control is a control method in which the speed of the cylinder is controlled using the cylinder supply flow rate.<br>With meter-in control, the exhaust conditions do not affect operation, and the piston can start moving quickly. (Cylinder lurching can be prevented.)
<br>Note) The accuracy will decline if IN side piping deviating from the recommended straight piping length or bore size is used.<br><br>
<br>The VX3 series catalog can be found here.<br><br>
<br>Be sure to check the specifications and precautions listed in the catalog of each type of tubing and fitting. <br>Note that LQ series piping requires a special tool. <br><br><br><br>Fittings and tubing catalogs can be found here.
<br>In this case, use the bypass piping set (optional accessory) to secure the flow rate. <br>Note) The temperature stability is as follows: ±2.0℃ for the HRSE, ±0.5℃ for the HRS090, and ±1.0℃ HRS100/150/200.<br><br>
<br>First, refer to the “Transport and Setting Up” section in the HRS series operation manual. <br>Wiring examples are shown in the “Wiring of remote operation signal input” and “Wiring of run/stop signal input・Remote signal input” sections. <br>Next, to enable remote signal input, change the communication mode from “LOCAL” to “DIO” mode.
<br>Please check the figure below. If the product is equipped with a control power supply, this control power supply circuit is provided. <br>If the operating power supply voltage is energized while the valve is open, it is acceptable not to drop it to the holding voltage.<br><br>
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: Y [DIN Terminal (EN175301-803C) w/Connector], Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Type
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: Y [DIN Terminal (EN175301-803C) w/Connector], Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Type, Manual)
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: YO [DIN Terminal (EN175301-803C) w/o Connector], Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Type
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: Y [DIN Terminal (EN175301-803C) w/Connector], Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Type, Manual)