SMC Corporation of America
Elite Part Number Search
Search Results "VNB311AS-T20A-5D-Q"

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Retaining, Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0.1 to

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-Position Closed Center, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-PositionExhaust Center, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure

Function: 2 Position Double, Body Option: Non Plug-in Type Sub-plate, Standard, Pilot Type: Internal Pilot, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: None, Port Size: w/o Sub-plate, Thread: Rc (Or None in Case of w/o Subplate), CE Compliant: CE-compliant

Type: Base Mounted, Valve Option: Standard Type, Rated Voltage: 24 VDC, Electrical Entry: DIN Terminal, Light/Surge Voltage Suppressor: None, Port Size: None, Thread: Rc, Bracket: None, CE-Compliant: CE-compliant

Type: Base Mounted, Valve Option: Standard, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: None, Port Size: w/o Sub-plate (Base Mounted Type), Thread: Rc (or for M5), CE Approval: CE Approval

The VN series is a combination of process valves that can be operated with pressure differential zero and comes with many variations. The VNA series is used for controlling pneumatic systems or air-hydro circuits. The VNB series controls various fluids. VNC is used for controlling the cutting oils and coolants used in machine tools. VNH is for controlling high pressure cutting oils and coolants

The VN series is a combination of process valves that can be operated with pressure differential zero and comes with many variations. The VNA series is used for controlling pneumatic systems or air-hydro circuits. The VNB series controls various fluids. VNC is used for controlling the cutting oils and coolants used in machine tools. VNH is for controlling high pressure cutting oils and coolants

Size: Port Size 3/4, Number of Ports: 2 Port, Valve Type: 3 [NC (Operating Pressure 7.0MPa)], Gasket: FKM Seal, Thread: NPTF, Port Size: 3/4, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Bracket: None, X200: X200

Size: 3 [ø20(ø14)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: A (NBR seal), Thread: T (NPTF), Port Size: 20A (3/4), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Bracket: B (Bracket)

Size: 3 [ø20(ø14)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: NPTF, Port Size: 3/4, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Manual Override: Non-locking Push Style, Bracket: Bracket, CE Compliant: -

Size: 3 [ø20(ø14)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: A (NBR Seal), Body Material: Standard, Pilot System Option: V (Vacuum Pilot), Thread: F (G(PF)), Port Size: 20A (3/4), Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal), Manual Override: Non-locking Push Style, Bracket: None, X200: No, CE Compliance: Q (CE Compliance)

Function: 2 (2 Position Double), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1), Thread: N (NPT), CE Compliant: Q (CE-compliant)

Function: 1 (2 Position Single), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1), Thread: F (G), CE Compliant: Q (CE-compliant)

Function: 2 (2 Position Double), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1), Thread: T (NPTF), CE Compliant: Q (CE-compliant)

Function: 1 (2 Position Single), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1), Thread: Rc (Or None in Case of w/o Subplate), CE Compliant: Q (CE-compliant)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product, and replaced byVT307-5D1-02F-Q

This is a legacy product. Please contact us for the latest version.sales@ocaire.com