IDFA Series 6-1 Specifications 6 1 IDX-OM-W016 Air dryer6 References 6-3 Dimensions DRAFT AIR OUTLET IDFA3E B Q A E D AIR INLET VENTILATION WITH LAMP SWITCH AIR OUTLET THERMOMETER EVAPORATION G F C DRAFT AIR INLET DRAIN TUBE (O.D.10 LENGTH:0.8m) VENTILATION (820) J TERMINAL BLOCK N L K M H GROMMET POWER SUPPLY ENTRY(17) P Measuremm Model Thread size A B C D E F G H J K L M N P Q IDFA3E Rc3
. (+/10%), 50/60Hz Current consumption Max.5A(100V) Max.9A(100V) Max.4A(240V) Max.10A(100V) Max.4A(240V) Max.8A (200V) Max.2.5A(240V) Inrush current 50A or less Over current protection 10A 14A Do not modify or reconstruct the unit.
B Grommet 100 VAC With surge voltage suppressor 12 One-touch fitting C 110 VAC G H J K 3/8 D 200 VAC 4 10A C37 N.C. 1/2 E 230 VAC 15 15A 3/8 Stainless steel B N.O. F 24 VDC 1/2 G DIN terminal 24 VDC L M 5 20A C37 N.C. With surge voltage suppressor 3/4 20 H 100 VAC C N.O. Stainless steel J 110 VAC 6 25A N.C. N P C37 Stainless steel 25 1 K 200 VAC D N.O. L 230 VAC 7 32A N.C.
Note) A: Non-locking push type A (projecting) 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 4 Note 2) Valve size 1 to 4 10 5 6 Note 2) Note) B: Slotted locking type B (tool required) 7 Note 2) 2 15 Note 1) CE-compliant: For D or DZ only Note 2) Semi-standard Note 3) For other rated voltages, please consult with SMC. 3 20 25
rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more Guide assembly Adjustment bolt assembly None 736
(Standard wiring specification is double wiring) Blanking plate SSQ1000-10A-3 (1 set) 1 2 3 4 5 6 7 8 Stations U side Cylinder port fitting C6: One-touch fittings for 6 Note 5) For specifying two or more options, enter them alphabetically.
N.C. 6A 8A 10A 10A 15A 20A 25A 32A 32F 40A 40F 50A 50F 1 8 1 4 3 8 3 8 1 2 3 4 7 1 15 2 20 3 25 4 1 1 1 4 32 5 11 4 B Flange 11 2 40 6 11 2 B Flange 2 50 7 2B Flange 634
GFCI 5. 6. 7. 10-2 IDU22E/37E/55E-23-R 10A 30mA IDU75E-23-R 20A 30mA IDU22E/37E/55E-30-R 10A 30mA IDU75E-30-R 15A 30mA IDU Series 10-1 10 1 IDX-OM-W029 10 R 10-3 1) 2) 3) M5 9.5mm 2 1.25mm N L L ,N () 6.5mm () Connect to earth cable GFCI Connector width AC230V 6.5mm or less M5 Electrical entry 9.5mm 2 1.25mm L01,L02,L03 L01 L02 L03 L1 L2 PE L3 () M3 () 6.5mm
The instructions described in this manual must be followed in addition to ISO 4414*1) and JIS B 8370*2) and other safety regulations. *1) ISO4414: Pneumatic fluid power Recommendations for the application of equipment to transmission and control systems. *2) JIS B 8370: General rules for pneumatic equipment.
2 2-1 IDF22E75E 54116kgIDF22E,37E 4 IDF55E,75E 2-2 2 2 1 2000m 240 050 600 mm 600 mm 600 mm 600 mm ( ) 600 mm IDF Series 2-1 2 1 IDX-OM-W026 2 2 2 2 6 6-3 IDF-AB500 14 1 IDF22E,IDF37E,IDF55E,IDF75E 2 2 3 50 50 OUT IN (IN) (OUT) IDF-BP317 1 IDF22E IDF-BP318 1 IDF37E IDF-BP325 1 IDF55E IDF75E 2 2 4 10mm IDF Series 2-2 2 2 IDX-OM-W026 2 2 2 5 6-1 IEC () AC200V 30mA 10A
IDX-OM-W031-B PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFA22E-23C,K,L,R,T,V IDFA37E-23C,K,L,R,T,V IDFA55E-23C,L,R,T,V IDFA75E-23C,L,R,T,V This manual is intended to explain the installation and operation of the product.
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: K (Stainless Steel Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 02 [1/4 (10A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Bracket: B (Bracket)
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: K (Stainless Steel Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 02 [1/4 (10A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Bracket: B (Bracket)
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: C (Brass or BC6, Copper Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 02 [1/4 (10A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Bracket: B (Bracket)
) AC200V () [30mA 10A] 1.25mm 2 (16AWG) 812mm3 () 0.1m 30m (11 ) M3 6.5mm 2 5 2
(1 ) 2. 3. 0 IDFA Series 9-3 (ADH4000-04) 9 2 IDX-OM-W032 10 R 10 R 10-1 10-2 IDFA22E/37E/55E-23-R 10A 30mA IDFA75E-23-R 20A 30mA 10-3 (IDFA55E,75E) (IDFA55E,75E) M5 9.5mm 2 1.25mm L ,N N L () () IDFA Series 10-3 10-1 IDX-OM-W032 10 R 10-4 () () ONOFF 10-5 R 6-4 6-3 T 11-6 11-3 IDFA Series 10-4 10-2 IDX-OM-W032 11 T 11 T T 11-211-3 11-1 1. 2. 3.
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: C (Brass or BC6, Copper Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 02 [1/4 (10A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: C (Conduit)
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: C (Brass or BC6, Copper Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 02 [1/4 (10A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: G (Grommet)
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: K (Stainless Steel Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 02 [1/4 (10A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet)
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: C (Brass or BC6, Copper Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 02 [1/4 (10A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: G (Grommet)