Grease pack part no: GR-S-010 (10g) No. Description Note Qty. Seal 19 1 Gasket for cover 2 Size: 10, 15 Gasket for endcover 20 1 Applicable parts Size: 20, 30, 40 Gasket 4 Piston seal 21 4 Seal washer 23 2 A set includes all parts above. 248 Series CRQ2 Compact Rotary Actuator Rack & Pinion Style Construction With auto switch Size 20/30/40 With auto switch Size 10/15 !3 !0 !3 !
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, F29, 10 lb
Each replacement part is supplied with a grease pack (10g). When only a grease pack is needed, order with the following part number. Grease pack part numberGR-L-010 -40- Disassembly procedure Basic type Made to Order Fig. 14 (1) Loosen the hexagon socket head cap screws and remove the interchangeable table and parallel pin.
.: GR-L-010 (10g) O-ring B O-ring C 136
If grease is required for maintenance, order using the part number: GR-H-010 10g) Do not wipe off the grease applied to the sliding part of the air cylinder. If grease applied to the sliding part is forcibly removed, operation failure can result. The sliding part may turn black if the cylinder is operated for a long distance.
. : GR-S-010 (10g), GR-S-020 (20g) 32
[%F.S.] 2 1 0 OUT OUT OUT OUT 0 D 2D 3D 4D 5D IN IN IN IN 0 1 2 3 4 5 5 (5D) [] [] LFE13/8 inch 0.2 MPa LFE23/4 inch LFE31 inch (mm) D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 68 No.LFE*-OMY0008 4.0 3.5 3.0 2.5 [%F.S.]
32 3C 0D 06 32 OD Set at 25.0 deg.C 31 32 Reading internal sensor 2 01 32 05 32 36 39 0D 01 32 02 32 32 35 30 32 03 32 3F 0D Answer 25.02 deg.C 33 Reading external sensor 2 01 32 05 33 36 3A 0D 01 32 02 33 33 30 30 32 03 32 3C 0D Answer 30.02 deg.C 34 Reading alarm status 2 01 32 05 34 36 3B 0D 01 32 02 34 30 38 30 03 30 30 0D Answer ERR11 Answer -1.52 deg.C Reading offset 01 32 05 36 36 3D
31 32 35 30 30 03 32 3C 0D 06 32 OD Set at 25.0 deg.C 32 Reading internal sensor 2 01 32 05 32 36 39 0D 01 32 02 32 32 35 30 32 03 32 3F 0D Answer 25.02 deg.C 33 Reading external sensor 2 01 32 05 33 36 3A 0D 01 32 02 33 33 30 30 32 03 32 3C 0D Answer 30.02 deg.C 34 Reading alarm status 2 01 32 05 34 36 3B 0D 01 32 02 34 30 38 30 03 30 30 0D Answer ERR11 Reading offset 2 01 32 05 36 36 3D
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061)
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061)
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals)
(When operation is commanded through PLC, this alarm will be generated depending on the input signal interval and the holding time of signals)
B RESET >+JOG (01-052) >+B RESET 65 - 112 12 0 2 3 4 5 6 7 Alarm _Comment _058 (01-058) 3A B RESET No.base PLC <> 1 1ABS 2INC 2PLC 2 14.2[2] (P.54) Alarm _Comment _061 (01-061) 3D B RESET <>+ <>+Alarm _Comment _062 (01-062) 3E B RESET <> (01-096) C RESET <> (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON SVRE ON DRIVE ON (01-099) <> SET OFF
(PLC ) Alarm _Comment _061 (01-061) <> (1) ()1(ABS)2(INC) (2)PLC 15ms(30ms) 13.2[2](P.53) 3D B RESET (+)(-) Alarm _Comment _062 (01-062) (+)(-) 3E B RESET <> (01-096) C RESET <> -64- (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON (SVRE ON) DRIVE ON (01-099) <> SET OFF DRV C RESET <> <>12 (01-103) C RESET 1 [] A [a ] 2 [SW] [] A [a ] <> <>
In this case, loosen the screw with washer (3f) and place a lead wire (3d) into the bracket, and then re-tighten the screw. Caution DlN Terminal (Connection) The solenoid is wired with male terminals of DIN connector as shown below. Connect with corresponding terminals of the connector. Can be used as either + COM or COM.
In that case, loosen the self-up screw 3f, insert the lead wire into the bracket 3d and screw in the screw again. b) The maximum size of the crimped terminal 9 is 1.25mm2 to 3.5 for O terminal and 1.25mm2 to 4 for Y terminal. c) Use a cable with outside diameter of 6 to 12mm for the cable 8.
In that case, loosen the screw (3f) and place a lead wire into the bracket (3d), and then tighten it once again. b) The maximum size for the round terminal (9) is 1.25 mm23.5 and for the Y terminal is 1.25 mm24. c) Cable (8) outside diameter: 6 to 12 mm Note) For the one with outside diameter ranged between 9 to 12 remove the inside parts of the rubber seal (7) before using. 3.