Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC5V, Specification: Standard / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0~0.7, Driving Type: Linear Motion Spool, Seal Type
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC5V, Specification: Standard, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Pressure Differential Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0.15 to 0.7, Driving Type: Pilot Type Spool, Pilot
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: Individual EXH, Specifications: Standard, Voltage: S (5VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: M5 (Body Ported M5X0.8)
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: S (5VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: M5 (Body Ported M5X0.8)
Function: 2 (Normally Open), Piping: 4 (Base Mounted), Body Option: Individual EXH, Specifications: Standard, Rated Voltage: S (5VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: None, Port Size: M5 (Base Mounted M5X0.8)
Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: Individual EXH, Specifications: Standard, Rated Voltage: S (5VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: None, Port Size: M5 (Base Mounted M5X0.8)
Terminal resistance 1 1 1 9 5 9 5 9 5 SDSD+ SDSG SD+ SD+ SD+ SG SDSG SDSG Terminal resistance120 Master This product This product This product (first slave) second slave 31st slaves Do not connect any wire to other PIN numbers. Fig. 3-9 Connection of RS-485 Tips Both ends of the communication connection (the end nodes) need to be connected to the host computer.
Terminal resistance 1 1 1 9 5 9 5 9 5 SDSD+ SDSG SD+ SD+ SD+ SG SDSG SDSG Terminal resistance120 Master This product This product This product (first slave) second slave 31st slaves Fig. 3-10 Connection of RS-485 Tips Both ends of the communication connection (the end nodes) need to be connected to the host computer.
Terminal resistance 1 1 1 9 5 9 5 9 5 SDSD+ SDSG SD+ SD+ SD+ SG SDSG SDSG Terminal resistance120 Master This product This product This product (first slave) second slave 31st slaves Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-485 Tips Both ends of the communication connection (the end nodes) need to be connected to the host computer.
11 12 13 14 15 16 A b c d E F 11 No.JXC-OMU0004-A 3.2 PWR LED ON/ : ON/OFF : ALM ON/ ON/: LED SW (SW , ) FG ( ,) 7 LED SET 114 15 MANU AL 16 1 SP EED 16 1 16 1 ACCE L 16 1 CN1 CN2 CN3 CN4 I/O I/O *1 12 No.JXC-OMU0004-A h k n L 2.02.4[mm] W 0.50.6[mm] L W 3.3 1 2 DIN LECP1 (LECP1D-) 13 No.JXC-OMU0004-A 3.4 1 LECP1DINLECP1D 2M4 DIN A DIN ADIN 2 M4 M4 ,SG
P3 Connector type (this product) D-sub9P female connector (M2.60.45) Standard EIA RS-485, RS-232C Protocol Modicon Modbus This system Your system This system Your system 2 Internal 2 Internal SD+ RD circuit circuit 7 3 SDTD Circuit block diagram 5 5 SG SG When RS-232C is selected When RS-485 is selected [Tips] Serial RS-485 and RS-232C must be used separately.
It may cause an electric shock or fire. (2) Controller mount hole (mounting part for ground cable) is connected to SG (signal ground) in the controller. Do not ground the controller when the controller is used in positive grounding environment. (3) Dedicated grounding should be used.
It may cause an electric shock or fire. (2) Controller mount hole (mounting part for ground cable) is connected to SG (signal ground) in the controller. Do not ground the controller when the controller is used in positive grounding environment. (3) Dedicated grounding should be used.
r Note) Contact prolection circuit is required wnen connectng t 7 3 l C section detail Cross section BB tlccFio $liilB ToilB tiliilrflig[ RiddiU 0uiiles$nries D($ Specifications " ' I lxsrzgA: Stroke (mm) 50, 75, 100, 125, 150 Motof 2-phase stepping motor s-phase stepping motor Screw (mm) sg Lead 6 s8 Lead 12 68 Lead 6 eB lead 12 Max. pay load (hofizontal) 9kg 4.5k9 6kg 3kg Max. pay load
SET MODE PNP open collector output External output SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 AC100~240V Nil B RS-232C RS-232C + BCD Connection Method Connection with the Digital Flow Switch (Series PF2) Static Electricity Elimination Equipment Reduced-wiring Fieldbus System A COM COM COM B DC12V GND F.G. R.S. HOLD BANK1 BANK2 MULTI COUNTER:CEU5 UP COUNT PRESET FUNC.
SG 16 Frame ground Connected to frame ground if the shielded wire of the I/O signal cable is connected to the connector shell. FG Shell Note: The allocation of the output signals (/SO1 to /SO3) can be changed.
SG 16 Frame ground Connected to frame ground if the shielded wire of the I/O signal cable is connected to the connector shell. FG Shell Note: The allocation of the output signals (/SO1 to /SO3) can be changed.
Function 1 NC 2 NC White SD+ (transmitted data +) 3 SD+ SD+ 4 SDSDSD(transmitted data -) Black 5 NC SG (Signal ground) 6 NC 7 NC GND (Power supply 0V) 8 NC CN1 No.
Function Upper level device 1 NC NC White 2 SD+ (Transmit data +) pcs. 3 SD+ SD+ 4 SDSDSD(Transmit data -) Black 5 NC SG (Signal ground) 6 NC 7 NC GND (0 V power supply) 8 NC CN1 No. Function 1 DC1 (-) DC1 (+) 2 pcs. A wiring example of multiple controllers (3 pcs.) connected to an upper level device is shown below.
SET MODE PNP open collector output External output SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 AC100~240V Nil B RS-232C RS-232C + BCD Connection Method Connection with the Digital Flow Switch (Series PF2) A COM COM COM B DC12V GND F.G. R.S. HOLD BANK1 BANK2 MULTI COUNTER:CEU5 UP COUNT PRESET FUNC. LEFT RIGHT BCD DOWN SEL.