. +0.048 0 Y-J010SUS 3.3 3.2 8 10 +0.048 0 Y-J016SUS 5 6.5 12 10 Rod end cap T-bracket Flat type/CJ-CF MM Double clevis type cylinder A 7 TH 4-TC C0.5 +0.2 0 TU D D 0.1 0.3 TN 12 C0.5 N W L TX TV TK Round type/CJ-CR MM TDH10 A TY TT C0.5 TW RR L N Material: SUS304 W Part no. Applicable bore size (mm) TH TC TDH10 TK TN TT TU TV TW TX TY Material: POM Part no.

Nil S n Rc NPT G Nil TN TF M5 x 0.8 for Auto switch type -CQ2XB32-5 Auto switch type Standard Strokes Cylinder stroke (mm) Nil Without auto switch (with built-in magnet) Nil Without auto switch (with built-in magnet) Bore sizes (mm) Standard strokes (mm) Bore sizes (mm) Standard strokes (mm) Refer to "How to Order" on page 5 for auto switch model numbers.

4 3/4 2 5/16 5 1/8 2 7/8 2 7/8 2 7/16 5 1 3/8 1-14 1 5/8 2 3/8 1 2 9/16 5 1/8 2 7/8 2 7/8 2 11/16 5 1 3/4 1 1/4-12 2 2.375 1/2 1 1/4 2 13/16 5 1/8 2 7/8 2 7/8 2 15/16 6 1 3/8 1-14 1 5/8 2 1/4 7/8 2 13/16 5 3/4 3 1/8 3 1/8 2 13/16 6 1 3/4 1 1/4-12 2 2.375 3/8 1 1/8 3 1/16 5 3/4 3 1/8 3 1/8 3 1/16 6 2 1 1/2-12 2 1/4 2.625 3/8 1 1/4 3 3/16 5 3/4 3 1/8 3 1/8 3 3/16 BORE E EE(NPT) F G J K NT TN

Suffix for cylinder (Rod boot) Port thread type Air cushion Rubber bumper Nil Without rod boot J Nylon tarpaulin K Heat resistant tarpaulin Rod end thread M5 x 0.8 20, 25 Rc 32 to 100 NPT* 32 to 100 G* 32 to 100 Nil Male rod end F Female rod end Nil Rc 20 to 100 TN NPT 20 to 100 * In the case of w/rod boot, and a foot bracket or rod flange as a bracket, those parts are to be assembled at

(Example) CHDKDB50-100 TN Applicable Auto Switches/Refer to pages 431 to 490 for further details on each auto switch.

Head rectangular flange type 50 mm Nil TN TF Rc Single clevis Port position 63 mm 80 mm 100 mm NPT Double clevis Port and cushion valve location viewed from the side of piston rod end thread GF Rod trunnion Symbol Position Stroke Center trunnion Refer to the standard stroke table on the next page 345.

T-bracket Rod End Cap TN (U) (S + Stroke) TDH10 Round type/CJ-CR Flat type/CJ-CF +0.2 0 TU 7 12 4 x TC 12 TH TZ TX TK TT TW TY Material: Polyacetal TV Part no. Applicable bore size A D L MM N R W Flat type Round type CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 Part no.

Applicable bore size (mm) TH TC TDH10 TK TN TT TU TV TW TX TY Material: Polyacetal 20Part no.

Leave a space for wiring a proximity switch. 191 Power Clamp Cylinder 40, 50, 63, 80 Series CKZT How to Order CKZT Clamp Cylinder (Without Arm) 63 TN 120 T Power clamp cylinder European type Switch type T P TURCK P&F Bore size 40 50 63 80 40 50 63 80 Arm mounting position 30 45 60 75 90 105 120 135 30 45 60 75 90 105 120 135 Cylinder port Nil TN G NPT CKZT Clamp Arm 40 A015 C S Mounting hole

With shock absorber (1 pc. on port side) TN TF 20, 25, 32 BS The adjusting bolt is installed even when B or BS is selected.(Except 10) Standard stroke (mm) Refer to Standard Stroke on page 1529.

Port thread type Stroke adjusting unit suffix Symbol Bore size 16 Type M threads Rc NPT G Nil S Both ends One end Nil TN TF 25, 40 "S" is applicable for stroke adjusting units L and H.

Applicable bore size (mm) TH TC TDH10 TK TN TT TU TV TW TX TY Material: Polyacetal 20Part no.

MM DEA E -X D across flats KK UNF 2A EE NPT 202 holes drill and cbore NH cap screw tap NT-UNC Data (in) Bore size (in) MM KK NT XA NH YE WF TN NE EA EE DD A AA B CA D E NA 075 (3/4") 10-32 UNF 0.625 0.75 1.12 0.38 0.88 0.34 0.62 0.81 0.12 1.00 1/8 1.00 0.093 0.22 1/4-28 10-32 UNF 1/4-20 0.250 106 (1 1/16") 10-32 UNF 0.750 0.75 1.47 0.62 1.22 0.47 0.81 0.24 1.12 1.25 1/8 1.25 0.093 0.25 3

Action D Double acting Standard stroke (mm) Port thread type 6, 10, 16 20, 25, 32 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40, 50 Type M5 x 0.8 Rc1/8 NPT1/8 G1/8 Bore size 6, 10, 16, 20, 25 32 32 32 Symbol Nil TN TF Applicable Auto Switches/Refer to page P.68 to 72 for further information on auto switches.

Thread type Stroke adjusting unit position Symbol Bore size 16 Type M thread Rc NPT G Nil S Both ends One end Nil TN TF 25, 40 S is applicable for stroke adjusting units L and H.

CL 40 TN Port thread type Bore size (mm) Nil Rc NPT G TN TF Consult with SMC when replacing the lock-up unit with a bore size of 125 to 160. 154

.: GR-S-010 (10 g) Replacement Parts: Lock Unit CLG1B 40 TN N E Cushion Type Lock operation N A Spring locking (Exhaust locking) Rubber bumper Air cushion E P D Pneumatic locking (Pressure locking) Spring and pneumatic locking Port thread type Bore size (mm) Nil TN NPT Rc 153

CLS 125 A93 TN D UA Bore size (mm) Lock unit auto switch Nil Without auto switch Refer to the table below for applicable auto switch models Port thread type Lock unit built-in magnet Nil TN NPT TF G Rc Nil D Built-in magnet Without magnet (Without auto switch) Cylinder Unit/Applicable Auto Switches Load voltage Lead wire length (m) Applicable load Indicator light Auto switch model Special

Replacement Parts: Lock Unit CNA2 D 40 TN UA Bore size (mm) Number Nil Standard Long stroke Thread type L Nil TN TF Rc NPT G Unit assembly Locking direction (Both directions) The lock unit for a long-stroke cylinder is only applicable for flange type with bore size 50 to 100 and storoke 1001 or more. (Example: CNA2-100D-UAL) 158

.: GR-S-010 (10 g) Replacement Parts: Lock Unit CNG D 40 TN N UA Unit assembly Cushion type N A Rubber bumper Air cushion Locking direction (Both directions) Port thread type Bore size (mm) Nil TN Rc NPT 155