A: Orange B: Green Stations n 10 stations 11 12 13 14 15 16 17 stations M3 Terminal screw 298 323 335.5 348 360.5 385.5 398 410.5 L1 L2 L3 L4 287.5 312.5 325 337.5 350 375 387.5 400 272 288 304 320 336 352 368 384 (Rail mounting hole pitch 12.5) 13 17.5 15.5 14 12 16.5 15 13 1-6-105 SX5000: PC Wiring System Compatible (Flat ribbon cable type/Plug-in) SS5X5-45GUStations DC4 C6 C8 (Pitch) P
13 14 Average speed Va (mm/s) Collision speed V (mm/s) 13 13 13 13 18 42 41 42 41 23 31 31 31 31 41 36 19 19 19 19 27 84 75 84 75 84 75 36 47 47 47 47 66 57 Note) Use the average speed when calculating static moment.
Bore size (mm) 6 10 16 Z T S NB NA NN MM H GB GA FZ FY FX FT FC FB F D C B A 77 3 49 7 16 M6 x 1.0 M3 x 0.5 28 14.5 32 14 24 1.6 4.5 13 8 3 14 12 15 74 46 9.5 12.5 M8 x 1.0 M4 x 0.7 28 5 8 32 14 24 1.6 4.5 13 8 4 14 12 15 75 47 9.5 12.5 M10 x 1.0 M5 x 0.8 28 5 8 42 20 33 2.3 5.5 19 8 5 20 18.3 15 With Air Cushion/Dimensions other than the table below are the same as the table above.
-/22-MXS25L-10 13-/22-MXS25L-20 13-/22-MXS25L-30 13-/22-MXS25L-40 13-/22-MXS25L-50 13-/22-MXS25L-75 13-/22-MXS25L-100 13-/22-MXS25L-125 13-/22-MXS25L-150 797 MXS 1322Air Slide Table Specific Product Precautions Made to Order Dust cover and dust plug made by fluororubber -X52 Be sure to read this before handling.
Corrected air flow capacity = Air flow rate (Correction factor A x B x C x D) 4 Corrected air flow capacity = 0.3 m3/min (0.82 x 0.96 x 1 x 0.88) = 0.43 m3/min Corrected air flow capacity = 0.4 m3/min (0.95 x 0.93 x 1 x 0.88) = 0.51 m3/min 5 Select the model.
ALARM 24 Alarm output NO. 3 13 NO. 4 4 COM 12, 25 Common The output terminal common.
M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.
retraction end) Stroke adjuster at retraction end Stroke adjuster at extension end 22 (With stroke adjuster at extension end) N-M3 X 0.5 thread 5 deep 3.5 6.5 2-M4 X 0.7 thread 6 deep (Helisert) 4 4-M3 X 0.5 thread 4 deep 1 (With stroke adjuster at extension end) 15 40 30 23 10 F 12 3H9 3 deep +0.025 0 N -1 x F 2 +0.025 0 3H9 3 deep 12 6 M 0.5 22 24 Z ZZ (NN-1) x H G H 13 6.5 6.5 13 A B
10 10 REAH20 16 16 13 13 REAH25 25 M3 REAHT25 W REAHT32 40 W M1 M2 Static Moment Moment generated by the workpiece mass even when the cylinder is stopped Pitch moment M1 = WL Yaw moment M3 = W (L A) Roll moment M2 = WL (mm) Model REAH10 REAH15 REAH20 REAH25 REAHT25 REAHT32 A 15 17.5 19.5 23.5 0 0 L L A L M2 M1 M3 Since there are 2 guides, the guides central axis and the cylinders
1) 11 (Pitch) P=10.5 4.5 12.5 41.5 [48.5] + + + + + (Station 1) (Station n) 26.1 A A 13 10 41.5 [48.5] (Pitch) P=10.5 M3 x 0.5 (A port) 13.5 A A 13 10 (Pitch) P=10.5 11.5 M3 x 0.5 (A port) L plug connector (L) M plug connector (M) M8 connector (WO) Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.7 [60.9] 48.9 [51.1] 57.8 50.4 43.9 Refer
34/13 28/15 11/7 Compact 22/12 8/7 Max. instantaneous power consumption [W] Note 9) Basic 61 57 51 19 Compact 42 14 Note 1) Gripping force should be from 7 to 13 times the workpiece weight.
M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2C 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.
M2 Allowable Moment (Static moment/Dynamic moment) 100 100 85 96 CY1HT32 CY1HT25 CY1H25 CY1H20 CY1H15 CY1HT32 CY1HT25 CY1H25 64 56 (Nm) 50 40 30 50 40 30 20 28 26 M1 M2 M3 M2 M3 M1 Model Model 20 CY1H20 CY1H15 16 Moment (Nm) Moment (Nm) CY1H10 CY1H25 1.5 2.5 1.5 28 26 28 13 10 10 CY1H15 CY1HT25 10 16 10 56 85 56 2 2.5 3 4 5 2 3 4 5 CY1H20 CY1HT32 13 16 13 64 96 64 CY1H10 CY1H10 1.5 1 M3
CRBU2 CRB1 L1 + (3 x P) L1 + (3 x P) Q1 = M Q1 = M MSU L2 + (3 x P) L2 + (3 x P) L1 = L1 = CRJ L2 = L2 = Q2 = M Q2 = M CRA1 Size 10, 15 Size 20, 30, 40 Size 10, 15 Size 20, 30, 40 CRQ2 (mm) (mm) Q1 M3 M3, M4 M3, M4 M3, M4, M5 M4, M5, M6 Q2 M3 M3, M4 M3, M4 M3, M4, M5 M4, M5, M6 Size 10 15 20 30 40 Size 10 15 20 30 40 MSQ MSZ CRQ2X MSQX Symbol: A4 Symbol: A5 Symbol: A3 The long shaft can be
) L2 M3 M3 F F C side A side C side A side 1/4 H3 (E3) G 1 G 25 H3 L3 (L1) (L1) (L3) Class 2 to 5 Class 2 to 5 Type T3 Type T4 Class 6 Metric Size Model A side (Left) B side (Center) C side (Right) B E1 E2 E3 F G H1 H2 H3 L1 L2 L3 M1 M2 M3 Min. port size Applicable tubing O.D.
(Tightening torque of M3 screw should be 0.5 to 0.7 Nm.) Auto Switch Mounting Bracket Part No.
(Tightening torque of M3 screw should be 0.5 to 0.7 Nm.) Auto Switch Mounting Bracket Part No.
(Tightening torque of M3 screw should be 0.5 to 0.7 Nm.) Auto Switch Mounting Bracket Part No.