PA02] 0 0 Select a regenerative option. 00: Regenerative option is not used. 00: 100 W 0.2 kW 7 kW 11 kW 22 kW 01: FR-BU2FR-RC FR-CV 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50 () 08: MR-RB31 09: MR-RB51 () 0B: MR-RB3N 0C: MR-RB5N ( ) FA: 11 kW 22 kW UP For drivers of LECSN-T5, do not use a regenerative resistor.
G46-10-01 2 pcs. G27-10-R1-X209 2 pcs. G27-10-R1-X209 2 pcs. G46-10-01 2 pcs.
1/2-16 73 : M12 x 1.75 This chart represents all current 13 : 1/4-20 41 : 1 1/2-12 74 : M14 x 1.75 thread codes and are not all 14 : 1/4-28 42 : 12-24 75 : M14 x 2.0 15 : 5/16-18 43 : 3/8-20 76 : M16 x 1.5 applicable to NCA1 due to rod 16 : 5/16-24 44 : 2 1/2-12 77 : M16 x 2.0 size limitations.
(Band & Screw included) Auto switch models 25 32 40 Bore size (mm) 20 Bore size (mm) D-C7, D-C8 D-H7 D-B5, D-B6 D-G5, D-K5 D-A3, D-A4 Axial foot CHM-L032 CHM-L040 CHM-L020 CHM-L025 Flange CHM-F032 CHM-F040 CHM-F020 CHM-F025 20 BMA2-020 BA-01 BD1-01M When ordering the axial foot type, order 2 pcs. for each cylinder. 25 BMA2-025 BA-02 BD1-02M 32 BMA2-032 BA-32 BD1-02 40 BMA2-040 BA-04 BD1-
(incl. band & screws) 25 32 40 Bore size (mm) 20 Auto switch models Bore size (mm) Axial foot CHN-L032 CHN-L040 CHN-L020 CHN-L025 D-C7, D-C8 D-H7 D-B5, D-B6 D-G5, D-K5 D-A3, D-A4 Flange CHN-F032 CHN-F040 CHN-F020 CHN-F025 When ordering the axial foot type, order 2 pieces for each cylinder. 20 BMA2-020 BA-01 BD1-01M 25 BHN3-025 BHN2-025 BD1-02M 32 BHN3-032 BGS1-032 BHN1-032 40 BHN3-040 BH2
1/2-16 73 : M12 x 1.75 This chart represents all current 13 : 1/4-20 41 : 1 1/2-12 74 : M14 x 1.75 thread codes and are not all 14 : 1/4-28 42 : 12-24 75 : M14 x 2.0 15 : 5/16-18 43 : 3/8-20 76 : M16 x 1.5 applicable to NCA1 due to rod 16 : 5/16-24 44 : 2 1/2-12 77 : M16 x 2.0 size limitations.
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
Solenoid Direction: S (Same Side of A Port), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 05, Port Size: 01 (Rc 1/8), Thread: T (NPTF)
Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 05, Port Size: 01 (Rc 1/8)
Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 05, Port Size: 01 (Rc 1/8), Thread: T (NPTF)
Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 05, Port Size: 01 (Rc 1/8), Thread: N (NPT)
Type A mounting bracket Type B mounting bracket 32, 40 YU-03 YA-03 YB-03 25 50, 63 YU-05 YA-05 YB-05 40 Material: Precision die-casting material equivalent to stainless steel 304 80 YU-08 YA-08 YB-08 90 Bore size (mm) O M J E D B Part no. 100 YU-10 YA-10 YB-10 160 K (Width across flats ) YB-03 32, 40 11.5 depth 7.5 34 9 25 7 12 H (With locking) YB-05 50, 63 14.5 depth 8.5 42 11 32 9 12 YB
B bracket A bracket YB-03 YU-03 YA-03 32, 40 25 YB-05 YU-05 YA-05 50, 63 40 Bore size (mm) YB-08 YU-08 YA-08 80 90 Part No. B D E J M O YB-10 YU-10 YA-10 100 160 12 YB-03 7 25 9 34 11.5 Depth 7.5 32, 40 12 YB-05 9 32 11 42 14.5 Depth 8.5 50, 63 16 YB-08 11 38 13 52 18 Depth 12 80 19 YB-10 14 50 17 62 21 Depth 14 100 Weight (g) Bore size (mm) Part No.
Type A mounting bracket Type B mounting bracket 32, 40 YU-03 YA-03 YB-03 25 50, 63 YU-05 YA-05 YB-05 40 Material: Precision die-casting material equivalent to stainless steel 304 80 YU-08 YA-08 YB-08 90 Bore size (mm) O M J E D B Part no. 100 YU-10 YA-10 YB-10 160 K (Width across flats ) YB-03 32, 40 11.5 depth 7.5 34 9 25 7 12 H (With locking) YB-05 50, 63 14.5 depth 8.5 42 11 32 9 12 YB
42 53 53 73 73 90 9 9 10.5 10.5 12.5 12.5 13 MB-B03 MB-B05 MB-B08 MB-B12 Rotating Angle Mounting plate Model without air cushion is designed to include rubber bumpers.
MNB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com YA 03 YA-03 YA-05 YA-08 YA-10 32, 40 50, 63 80 100 42 50 62 76 6 8 10 12 16 20 25 30 6.5 6.5 8.5 10.5 6.8 9 11 14 18 20 26 31 10 12 16 18 CNA Applicable air cylinder bore CNS 03 05 08 10 32, 40 50, 63 80 100 Mounting
Bore size (mm) T1 M F E D B T2 Part no. 42 50 62 76 6 8 10 12 16 20 25 30 6.8 9 11 14 18 20 26 31 6.5 6.5 8.5 10.5 10 12 16 18 YA-03 YA-05 YA-08 YA-10 32, 40 50, 63 80 100 YA 03 Applicable cylinder bore size 32, 40 50, 63 80 100 03 05 08 10 Mounting bracket Bore size (mm) W V U Weight (g) Part no.
Bore size (mm) T1 M F E D B T2 Part no. 42 50 62 76 6 8 10 12 16 20 25 30 6.8 9 11 14 18 20 26 31 6.5 6.5 8.5 10.5 10 12 16 18 YA-03 YA-05 YA-08 YA-10 32, 40 50, 63 80 100 YA 03 Applicable cylinder bore size 32, 40 50, 63 80 100 03 05 08 10 Mounting bracket Bore size (mm) W V U Weight (g) Part no.
Driver Non-standard motor electric actuator Standard motor electric actuator Controller How to Order How to Order B LG1 02 1 Compatible model 1 G LG1 05 Cable length G R Y Matsushita Electric Industrial Co., Ltd. Mitsubishi Electric Corporation Yaskawa Electric Corporation 02 03 04 05 05 5m Cable length 2m 3m 4m 5m Applicable cables Model Manufacturer part no.
Driver Non-standard motor electric actuator Standard motor electric actuator Controller How to Order How to Order B LG1 02 1 Compatible model 1 G LG1 05 Cable length G R Y Matsushita Electric Industrial Co., Ltd. Mitsubishi Electric Corporation Yaskawa Electric Corporation 02 03 04 05 05 5m Cable length 2m 3m 4m 5m Applicable cables Model Manufacturer part no.