PA 02 200 VAC 50/60 Hz 01 100 VAC 50/60 Hz 08 48 VAC 50/60 Hz 01 02 03 04 07 08 05 06 002 Applicable valve model No. 13 24 VAC 50/60 Hz VXZ22 VXZ23 03 110 VAC 50/60 Hz 23 440 VAC 50/60 Hz PAX 003 AC 04 220 VAC 50/60 Hz 51 6 VDC Coil combination code 05 24 VDC 53 48 VDC PB 06 12 VDC 55 100 VDC 56 110 VDC (Refer to the table below.) 07 240 VAC 50/60 Hz DC Note) The voltage codes

11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 1/4, 3/8 VCS41 30 50 94 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 3/4 4 Direct Operated 2 Port for Steam Series VCS How to Order Manifolds How to Order Manifold Assemblies (Example) D VV2C S 2 02 01 Enter the valve and option models to be mounted under

11 17 36 22.5 23 M5 8 1/4, 3/8 VCL41 111.5 26 26.5 66.5 48 64.5 62 62 50.5 103 64.5 70 30 50 93.5 41 13.5 17 36 25 23 M5 8 1/2 119 26 26.5 70 48 68 62 65.5 50.5 103 68 70 35 60 101 41 17.5 17 36 30 28.2 M5 8 3/4 Note) For class H 4 Direct Operated 2 Port for Oil Series VCL How to Order Manifolds How to Order Manifold Assemblies (Example) VV2C L 2 02 01 Enter the valve and option models

11 17 36 22.5 23 M5 8 1/4, 3/8 VCL41 111.5 26 26.5 66.5 48 64.5 62 62 50.5 103 64.5 70 30 50 93.5 41 13.5 17 36 25 23 M5 8 1/2 119 26 26.5 70 48 68 62 65.5 50.5 103 68 70 35 60 101 41 17.5 17 36 30 28.2 M5 8 3/4 Note) For class H 4 Direct Operated 2 Port for Oil Series VCL How to Order Manifolds How to Order Manifold Assemblies (Example) VV2C L 2 02 01 Enter the valve and option models

11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 1/4, 3/8 VCS41 30 50 94 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 3/4 4 Direct Operated 2 Port for Steam Series VCS How to Order Manifolds How to Order Manifold Assemblies (Example) D VV2C S 2 02 01 Enter the valve and option models to be mounted under

) 36 (33) 66 0.5 59 (54) 52 (49) 41 (39) 79 0.1 0.2 4 0.3 40 (30) 37 (29) 31 (23) 54 2) 46 (37) 49 (44) 41 (36) 68 0.5 63 (57) 57 (51) 46 (43) 82 0.1 0.2 6 0.3 43 (34) 39 (30) 35 (28) 54 2) 49 (41) 53 (50) 47 (43) 68 0.5 67 (64) 61 (59) 54 (51) 81 1) ( ) 2) ZQ05A0.35MPaZQ07AZQ10A0.43MPaZQ000A0.4MPa 3) (PD) V PD [MPa] ZQ05A ZQ07A ZQ10A ZQ000A 0.05 11 10 8 16 0.15 22 20 17 32 3.2 0.25

M1 M2 Weight (g) ASV310F-01-06S ASV310F-01-08S ASV310F-02-06S ASV310F-02-08S ASV410F-01-08S ASV410F-01-10S ASV410F-02-08S ASV410F-02-10S ASV410F-03-08S ASV410F-03-10S ASV510F-02-10S ASV510F-02-12S ASV510F-03-10S ASV510F-03-12S ASV510F-04-10S ASV510F-04-12S 71.9 73.8 71.9 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.8 90.2 91.8 90.2 91.8 16.8 19.3 16.8 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3

Y, Z directions 3limes each 12.6FS or lesis at 25'C 01: Rl/8. [.r5 x 0 8, Tl: NPT1/8, M5 x 0 8.

Refer to pages 2-5-40 to 2-5-43 for with control unit. 01 1 station Cylinder port D U D side entry U side entry C8 C10 C12 02 03 B CM With One-touch fitting for 8 With One-touch fitting for 10 With One-touch fitting for 12 Rc 1/4 Rc 3/8 Bottom ported Rc 1/4 Mixed 18 18 stations U D U D Note 2) Note 3) Note 4) Note) As an option, the maximum number of stations can be increased by special wiring

11 (0.6) 2 position double 110 SYJA7220-01 Body ported Base mounted (With sub-plate) 8.5 (0.47) 9 (0.5) [6.5 (0.36)] 3 position closed center SYJA7320-01 1/8 M5 X 0.8 3 position exhaust center SYJA7420-01 120 PA, B: 13.5 (0.75) [7 (0.39)] A, BR1, R2: 7 (0.39) 3 position pressure center SYJA7520-01 Base mounted 01 02 01 02 01 02 01 02 12.6 (0.7) 170 (90) 2 position single SYJA714012.6 (0.7

11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 1/4, 3/8 30 50 94 41 13.5 17 36 25 23 M5 8 VCS41 26 88 48 78.5 103 78.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 3/4 17-2-45 8 Series VCS How to Order Manifold How to Order Manifold Assembly VV2C S D 2 02 01 Enter the mounting valve and option part numbers under the manifold base part number.

0.84 0.23 0.47 0.58 2.1 [0.83] center [0.25] [0.55] Note 1) P, A, B Port: Rc1/8 is R1, R2 port: Rc (PT) 1/4 Note 2) [ ]: Denotes normal position Note 3) ( ): Without sub-plate Note 4) 5 port base mounted without sub-plate: SYJA40 5-2-27 10 Series SYJA7000 Dimesions: Body Ported Dimensions: Base Mounted 01 02 2 position single: SYJA7120-01(-F) 2 position single: SYJA714060 2-4.3 28.3 M5 x

Kodanska 46, CZ-100 10 Prague 10 Phone: 02-67154 790, Fax: 02-67154 793 Hungary SMC Hungary Kft. Budafoki ut 107-113, 1117 Budapest Phone: 01-204 4366, Fax: 01-204 4371 Sweden SMC Pneumatics Sweden A.B. Ekhagsvgen 29-31, S-14105 Huddinge Phone: 08-603 07 00, Fax: 08-603 07 10 Ireland SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co.

ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).

ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).

/02--X693 PFM7S-01/02--X693 A B C() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3 36.3 C6 6 10.3 8.3 C8 8(5/16) 12 37 C8 8(5/16) 12 10 N7 1/4 10.3 36.3 N7 1/4 10.3 8.3 PFM7-01/02--X694 PFM7S-01/02--X694

( 01, -02 and -03 after model no. means port size{01 1/8,02' 114,03 3/8,04 1/2} 5 Filter I Regulator Series AW e How to Order AW 01 Filte~ Regulator '-Optional specifications 0.02~0.2MPa 1 (0.2 ~ 2.0kgf/cm2) setting Accessory (optional) 20 1/8 Type of thread Body size _-1 2 Metal bowl 6 Nylon bowl Description Applicable model Symbol 8 Metal bowl with level gauge ~ ~ ~ ( pn 0 (Only AW3001

Drain guide 1/4 Note 4) AFM30, 40 Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right to left AFM20 to 40 N Note 1) Float type auto drain (N.O.)

Setting of the selected alarm Setting range: AL.01 to AL.51 to 63. Press the [MENU] key once. Returns to the main display (which shows the circulating fluid temperature).

Applicable bore size C D d H Applicable bore size C D d H 5 12.5 15 26 30 M8 x 1.25 8 M22 x 1.5 26 13 20 20 SOR-20 NT-02 6 16.5 19.6 32 36.9 M10 x 1.25 8 M24 x 1.5 32 17 25/32 25 SOR-25 NT-03 8 21.0 25.4 38 43.9 M14 x 1.5 9 M30 x 1.5 38 22 40 32 SOR-32 NT-04 11 26 31 41 47.3 M18 x 1.5 11 M33 x 2.0 41 27 50 40 SOR-40 NT-05 11 26 31 M18 x 1.5 27 63 NT-05 13 31 37 M22 x 1.5 32 80 NT-08 16 39