SMC Corporation of America
Elite Part Number Search
Search Results "RZQB50TN-50-5"

0.03 5 0.01 10 20 30 40 50 100 10 20 30 40 50 100 Overhang L (mm) Overhang L (mm) 10 to 32 Graph V = up to 200mm/s 3 Graph V = up to 400mm/s 4 4 20 3 10 32 5 25 1 Weight m (kg) Weight m (kg) 32 20 25 0.5 1 20 15 0.5 15 10 CXSM CXSL CXSM CXSL 10 5 0.1 5 0.1 10 20 30 40 50 100 10 20 30 40 50 100 Overhang L (mm) Overhang L (mm) Graph V = up to 600mm/s 5 Graph V = up to 700mm/s (up to 800mm/s

DISPLAY AND OPERATION SECTIONS 5 1 to 5 -30 5.1 Overview 5 2 5.2 Display sequence 5 3 5.3 Status display 5 4 5.3.1 Display transition 5 5 5.3.2 Display examples 5 6 17 5.3.3 Status display list . 5 8 5.4 Diagnostic mode 5 -10 5.5 Alarm mode 5 -12 5.6 Point table mode 5 -14 5.6.1 Point table transition 5 -14 5.6.2 Point table mode setting screen sequence 5 -15 5.6.3 Operation example

to 70/ 5 to 50 5 to 80/ 5 to 50 5 to 100/ 5 to 50 5 to 120/ 5 to 50 7 to 17 1.4 to 3.5 Opening and closing speed/ Pushing speed [mm/s] Note 2) Note 3) Actuator specifications Electric specifications Drive method Slide screw + Wedge cam 0.02 Repeatability [mm] Note 4) Repeated length measurement accuracy [mm] Note 5) 0.05 0.5 or less Finger backlash/dia.

B A C D 5 6 Standard Motor Series LJ1H10 Motor Output Slide Screw High Rigidity Direct Acting Guide 50W 20mm/20mm lead Horizontal Mount How to Order Stroke LJ1H101 SC 1 F 2 Cable entry direction Top entry Power supply voltage Cable entry direction Cable length Left entry 1 2 100/110VAC (50/60Hz) 200/220VAC (50/60Hz) F R L T B Axial Right Left Top Bottom 2 3 4 5 2m 3m 4m 5m Axial entry Right

1/4 stroke 1/4 stroke 1/4 stroke 1/4 stroke 1/5 stroke 1/5 stroke 1/5 stroke 1/4 3/8 3/8 1/2 1/2 1/2 1/2 3/4 40 50 63 80 100 125 140 160 207 3.2 3.2 3.2 4.5 6.0 8 9 9 70 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M30 x 1.5 M30 x 1.5 M36 x 1.5 244 36 45 45 60 60 75 75 75 252 42 50 59 76 92 100 112 118 27 30 31 37 40 35 35 39 16.5 16.0 16.0 18.0 18.0 40 40 40 84 90 98 116 126 98 98

/1100 Heating capacity (50/60 Hz)4 [W] 250/300 Temperature stability5 [C] 0.1 Pump capacity (50/60 Hz)6 [MPa] 0.09 (at 5 L/min)/0.11 (at 5 L/min) For Option T1: 0.35 (at 5 L/min)/0.35 (at 5 L/min) Circulating fluid system Rated flow (50/60 Hz)7 [L/min] 5/5 For Option T1: 5/5 Flow display range20 [L/min] 2 to 16 Electric conductivity display range [S/cm] 0.1 to 48 (Only for Option DM) Electric

Tuning Procedure.5-44 5.5.3 One-parameter Tuning Example.5-48 5.5.4 Related Parameters.5-49 5.6 Anti-Resonance Control Adjustment Function (Fn204).5-50 5.6.1 Anti-Resonance Control Adjustment Function.5-50 5.6.2 Anti-Resonance Control Adjustment Function Operating Procedure.5-51 5.6.3 Related Parameters.5-51 5.7 Vibration Suppression Function (Fn205).5-52 5.7.1 Vibration Suppression Function

to 100 0.01 50 Immediately Tuning The filter is disabled if 5000 is set. 5-68 6.

Standard Stroke Bore size (mm) Standard stroke (mm) 20 25 32 40 50 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Intermediate strokes of 1 mm each can be produced.

[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.

CJP CJ2 CM2 Bore (mm) TG1 E1 EW FL L1 L L2 d1 CD MR d2 R1 E2 UB CB 45 51 64 74 94 113 26 28 32 40 50 60 32.5 38 46.5 56.5 72 89 22 25 27 32 36 41 5 5 5 5 5 5 12 15 15 20 20 25 5.5 5.5 6.5 6.5 10 10 30 35 40 45 45 55 10 12 12 16 16 20 9.5 12 12 16 16 20 6.6 6.6 9 9 11 11 6.5 6.5 8.5 8.5 11 12 48 56 64 75 95 115 45 52 60 70 90 110 26 28 32 40 50 60 32 40 50 63 80 100 C85 C76 CG1 Rear Sngle

AD37 AD37N(5) AD48 AD48N(5) AD47 AD47N(5) AD48 AD48N(5) Float type auto-drain N.O.

With lead wire ZS-20-A ZS-20-5A-50 0.6 m 3 m 5 m Nil 30 50 (The flow characteristics are for the supply pressure of 0.5 MPa.)

SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.

RHC Load voltage 24 VDC 100 VAC 200 VAC Load current range (2) 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MK(2) Contact protection circuit Built-in Internal voltage drop RS Q G 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA) Indicator light Auto Switch Internal Circuit D-A33C Red LED lights when ON.

Refer to the Specific Product Precautions. 0.5 45.5 1.5 50 Z ZZ H G (NN 1) x H 11.5 29 11.5 29 B A 5.1 9.5 11 11 5H9 depth 5 +0.030 0 30 NN x M6 x 1 thread depth 12 A B 6 HA GA Section AA Section BB 5H9 depth 5 +0.030 0 (mm) Model F 50 50 50 60 35 60 70 70 80 FF 40 40 40 50 35 60 70 70 80 N 4 4 4 4 6 6 6 8 8 G 15 15 15 15 15 19 37 41 19 H 45 45 45 55 35 35 35 38 44 NN 2 2 2 2 3 4 5 6 7 GA

Operating Range Operating Range (Dimensions) (mm) Auto switch model Bore size 20 25 32 40 50 63 D-M9/M9V D-M9W/M9WV D-M9AL/M9AVL 4.5 4.5 5 5 6.5 5.5 6.5 6.5 9 9.5 9 9.5 9.5 11 D-A9/A9V D-F7/J79 D-F7V/F79F/J79C D-F7W/F7WV D-F79F/F7BAL/F7BAVL/F7NTL 6 6 6 6.5 D-A7/A80 D-A7H/A80H D-A73C/A80C 9.5 11.5 11 13.5 9.5 5 D-A79W D-P4DWL 6 7 5 7 5 Since this is a guideline including hysteresis

17 3 16 4 16 M10 x 1.25 27 27 1/8 143 3.5 6.5 237 40 6 14 22 3 16 4 16 M14 x 1.5 27 27 1/4 157 4.5 9 259 50 7 18 27 4 16 5 16 M18 x 1.5 31.5 31.5 1/4 172 4.5 10.5 288 63 7 18 27 4 16 5 16 M18 x 1.5 31.5 31.5 3/8 184 5.5 12 300 80 10 22 32 5 16 5 17 M22 x 1.5 38 38 3/8 227 7.5 14 371 100 10 26 41 5 16 5 17 M26 x 1.5 38 40 1/2 247 9.5 15 391 Bore size S ZZ 32 149 243 40 163 265 50 180 296 63

Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 CJ1 Auto switch model Applicable load PLC Relay, PLC CJP Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA CJ2 Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (