SMC Corporation of America
Elite Part Number Search
Search Results "RLQA63TN-100-FR"

CR ,, (EE ) 2ROM E 2ROM (100 ,E ), 2ROM E (3) : # : ASCII ,, 30H ) # 0 0 V R 23H 30H 30H 56H 52H 23H+30H+30H+56H+52H=12BH 2B ,30H 32H 3BH : # 0 0 V R 2 ; [CR] 23H 30H 30H 56H 52H 32H 3BH 0DH )ASCII ASCII 09 A B C D E F ASCII 30H39H 41H 42H 43H 44H 45H 46H 30H39H 3AH 3BH 3CH 3DH 3EH 3FH 27 - (4) 1bit () bit (ON 1) b7 b6 b5 b4 b3 b2 b1 1 0 () ON () (5) VR # 0 0 V R [CR] No. #

(Page 11) Allowable lateral load at the rod end 10.0 fR: Lateral load applied to rod end Ft: Maximum force of cylinder Lateral load applied to rod (N) Bushing (bearing) CJ2*16 1.0 CJ2*10 CJ2*6 0.1 0 50 100 150 200 Cylinder stroke (mm) Fig. 1 Allowable lateral load applied to rod end 2) Make sure to connect the piston rod and the load so that their axial centers and movement directions match

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Maintenance Caution Tube deformation ratio at the minimum bending radius = LD 2d 1 x 100 1.

Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): D (1/3 reduction: LET80: 43.33, LET100: 80), Stroke: 300mm, Motor Option: Nil (without option), Cable Type: S (Standard Cable), Cable Length: 5 (5m), Driver Type: B2 (200-240V, LECSB2-T_), I/O Cable Length: Nil (without cable)

Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): M (1/9 reduction: LET80: 14.44, LET100: 26.67), Stroke: 3000mm, Motor Option: B (with Lock), Cable Type: R (Robotic Cable), Cable Length: 5 (5m), Driver Type: B2 (200-240V, LECSB2-T_), I/O Cable Length: 1 (1.5m)

Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): N (1/15 reduction: LET100: 16), Stroke: 3000mm, Motor Option: Nil (without option), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver Type: B2 (200-240V, LECSB2-T_), I/O Cable Length: Nil (without cable)

Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): M (1/9 reduction: LET80: 14.44, LET100: 26.67), Stroke: 800mm, Motor Option: Nil (without option), Cable Type: Nil (without cable), Cable Length: Nil (without cable), Driver Type: Nil (without driver), I/O Cable Length: Nil (without cable)

Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): D (1/3 reduction: LET80: 43.33, LET100: 80), Stroke: 700mm, Motor Option: B (with Lock), Cable Type: S (Standard Cable), Cable Length: 2 (2m), Driver Type: B2 (200-240V, LECSB2-T_), I/O Cable Length: 1 (1.5m)

Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): N (1/15 reduction: LET100: 16), Stroke: 700mm, Motor Option: Nil (without option), Cable Type: S (Standard Cable), Cable Length: 5 (5m), Driver Type: B2 (200-240V, LECSB2-T_), I/O Cable Length: Nil (without cable)

Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): N (1/15 reduction: LET100: 16), Stroke: 700mm, Motor Option: Nil (without option), Cable Type: Nil (without cable), Cable Length: Nil (without cable), Driver Type: Nil (without driver), I/O Cable Length: Nil (without cable)

Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): N (1/15 reduction: LET100: 16), Stroke: 1200mm, Motor Option: B (with Lock), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver Type: B2 (200-240V, LECSB2-T_), I/O Cable Length: 1 (1.5m)

, and center trunnion , With or without rod boot , Variety of switches and a variety of lead wire lengths, MFLD SUB-ASSY W/TERM., VALVE, VV*FR* NO SIZE RATING, .48400 lb

, and center trunnion , With or without rod boot , Variety of switches and a variety of lead wire lengths, MFLD SUB-ASSY W/TERM., VALVE, VV*FR* NO SIZE RATING, .46200 lb

, Ambient & fluid temperature: -10 to 50°C, VALVE, 3 POSITION PLUG-IN (DC) COPPER FR, 4/5 PORT SOLENOID VALVE, 77 lb

Bore sizes in mm: 12, 16, 20, 25, 32, 40, 50, 63, 80, 100, Strokes from 5mm to 100mm depending upon bore size, Mounts: through hole, both ends tapped, foot, front and rear flange, double clevis, rear boss, Variety of switches and a variety of lead wire lengths, CYL, COMPACT, SGL ACT, SP *LQA, ACTUATOR, NCQ2 COMPACT CYLINDER, FR, 12MM NCQ2 SPR RET-AUTO-SW, .12012 lb

[N] Load direction Size Basic type Fsa Fsb Fr M [Nm] 10 78 74 78 2.4 20 137 137 147 4.0 30 363 197 196 5.3 50 451 296 314 9.7 Bolts for mounting product When mounting the body, use screws of the appropriate length. Basic type 1.

size d 15-3-4 5 Flame Resistant (Equivalent to UL-94 Standard V-0) FR One-touch Fittings Series KR Plug-in Reducer: KRR Effective area (mm 2) FR soft nylon FR double layer Applicable tubing O.D.

Series RLQ is a compact cylinder with a built-in lock and air cushion.  Should the air supply be cut off, the RLQ was designed by SMC to provide the safety of drop prevention at any point of the stroke.  Additional features include standardized bypass piping, and a home position holding function.  The RLQ is the perfect solution for applications which require larger kinetic energy, high

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 50mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking), By-Pass Piping: R (w/By-Pass, Right-Hand Piping, Drop Prevention)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 50mm, Port Thread Type: TN (NPT), Stroke: 100mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking), By-Pass Piping: R (w/By-Pass, Right-Hand Piping, Drop Prevention)