1 Drain q r e w t i u y o !0 !
MN MO WO W L plug connector 3 M plug connector 220 VAC50/60Hz [230 VAC50/60Hz] 4 For type "W", DCvoltage is only available.
SY Side/Bottom ported 3 1 3 0 5 1 W1 M5 01 SY Top ported q w r e t y u i o !
Example) 26NW 01 11 21 31 41 q w e w q Note 3) Only adjusting spring of regulator is different from standard specification. Note 4) Without valve mechanism. q q q w w w e (1) Numbers in . indicate order of constructtion of equipment from left hand side (the upper stream side) from a view of front side. Ex.)
Nil A B C D q w e q w q w w q e q w The number inside indicates the combination order counted from the inlet side.
Grommet (G), (H): SY3240(R)-01 Scale: 35% G H With interface regulator 141 15 68.5 [75] 65.6 68 32.5 24.5 With plug (12.5) (37) 41 L type plug connector (L): SY3240(R)-L-01 M type plug connector (M): SY3240(R)-M-01 Grommet .
17 8.5 24 2 x 4.3 (For mounting) 37.5 4 Manual override A B B A P R 41 0.5 G: Approx. 300 H: Approx. 600 (Lead wire length) 63.6 [65.8] (Light/surge voltage suppressor) 50.1 [57.1] + 45 8.5 34.7 21.5 6 6 45.5 17 17 15 1/8 (P, R port) 32 24 L plug connector (L): 10-SYJ5143-L-01 M plug connector (M): 10-SYJ5143-M-01 DIN terminal (D, Y): 10-SYJ5143-01 M8 connector (WO): 10-SYJ5143-WO-01 D Y
A Drain cock with barb fitting: 6 x 4 nylon tube W AC25 to 60 G M G M Note 3) Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, F) Z AC10 to 60 M G A G M When more than one specification is required, indicate in ascending alphanumeric order.
(M): SY3140(R)-M-01-Q VQ5 VQZ VQD VFS VS VS7 VQ7 1.2-33 Base Mounted Type Series SY3000 Dimensions Note)< >: Values with surge voltage suppressor 2 position double Grommet (G), (H): SY3240(R)-01-Q Scale: 35% G H With interface regulator 141 15 68.5 65.6 68 32.5 24.5 With plug (12.5) (37) 41 L type plug connector (L): SY3240(R)-L-01-Q M type plug connector (M): SY3240(R)-M-01-Q 1.2-34 Base
ZS-20-A 16 NPN open collector 2 output w/o analog output, 3 turns adjustment With lead wireZS-20-5A17 NPN open collector 2 output w/o analog output, 200 degrees adjustment Note) When ordering switch with 5 m long lead wire, indicate both part numbers. Lead wire length 18 NPN open collector 1 output w/analog output, 3 turns adjustment 0.6 m Nil Ex.) ZSE1-01-15CN1 pc.
Load factor: ( (Load weight x 9.8)/Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 8 x 1 m AS3301F-08 AN110-01 Series MB/CA2 Series CJ2 Series CM2 4 x 1 m Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AS2301F-04 6 x 1 m 4 x 1 m AS1301F-04 AN120-M5 SYJ5120-M5 SYJ5140-01 AN101
Cable length VVFS2000-30A-1 VVFS2000-30A-2 VVFS2000-30A-3 VVFS2000-30A-4 VVFS2000-30A-5 VVFS2000-30A-6 VVFS2000-30A-7 1.5 m 3 m 5 m 7 m 10 m 15 m 20 m 1.5 m 3 m 5 m 8 m 10 m 15 m 30 m VVZS3000-21A-1 VVZS3000-21A-2 VVZS3000-21A-3 VVZS3000-21A-4 VVZS3000-21A-5 VVZS3000-21A-6 VVZS3000-21A-7 Plug 206837-1 1 pc. Cable clamp 206138-1 1 pc. Socket 66101-2 24 pcs.
G46-10-01 0.02 to 0.2 MPa setting G27-10-R1 G36-4-01 G46-4-01 Round type (with color zone) Standard G36-10-01-L G46-10-01-L 0.02 to 0.2 MPa setting G36-4-01-L G46-4-01-L Square embedded type 2 Standard GC3-10AS [GC3P-010AS (Pressure gauge cover only)] 0.02 to 0.2 MPa setting GC3-4AS [GC3P-010AS (Pressure gauge cover only)] Option Pressure gauge 1 ISE35-N-25-MLA [ISE35-N-25-M (Switch
(g) Note 2) W = 65.4n + m + 128.2 W = 13n + m + 36 W = 41.2n + m + 77.6 (n: Number of SUP/EXH blocks, m: Weight of DIN rail) Note 1) In cases such as those where many valves are operated simultaneously, use station B (SUP/EXH block on both sides), applying pressure to the P ports on both sides and exhausting from the R ports on both sides.
T0604 x 1 m AS3001F-06 AN110-01 T0604 x 1 m AS3001F-06 VQZ1151-01 VQZ1121-C6 T0806 x 1 m AS3001F-08 VQZ2151-02 VQZ2121-C6 AN200-02 T1075 x 1 m AS4001F-10 AN300-03 T0604 x 1 m AS3001F-06 T1209 x 1 m AS4001F-12 VQZ3121-C6 VQZ3151-03 909 Series VQZ Model Selection Sonic conductance C [dm3/(sbar)] Type of actuation Voltage Electrical entry Light/surge voltage suppressor Manual override VQZ1000
Example) IS10E-30N03-6PRZ q Body size Description Symbol 20 30 40 Left Right Nil N Note) F Note) Thread type Rc NPT G w Pressure switch with piping adapter + 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 e Port size A + D 500 E 23 Nil 6 Note 1) 0.1 to 0.4 MPa 0.1 to 0.6 MPa Set pressure range a + Nil L Z 0.5 m 3 m 5 m r Semi-standard Lead wire length b Port size + C Nil P Note 2) MPa MPa/psi dual
01 01 01 01 01 01 01 01 01 01 01 01 01 01 153.5 156.5 189.5 192.5 118.5 123.5 01 153.5 158.5 01 01 01 189.5 194.5 01 55 Series ZP Heavy-duty Pad Dimensions: With Buffer 40 50 01 ZPT HB -A18 01 ZPT HB -A18 63 80 01 ZPT HB -A22 100 125 1/8 (Rc, NPT, NPTF) Width across flat 17 (Hexagon) M22 x 1.5 50 24 1/8 (Rc, NPT, NPTF) Width across flat 14 (Hexagon) 1/8 (Rc, NPT, NPTF) Width across flat
(For manifold type 20, 21R) 1 SYJ7 2 5 M 01 Body ported SYJ7 4 5 M 01 1 Base mounted Manual override 3 port Thread type Nil: Non-locking push type D: Push-turn locking slotted type Coil specifications F Nil Rc Nil Standard G N T NPT NPTF With power saving circuit (24, 12 VDC only) T Power saving circuit is not available in the case of D, DO, W type.
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Conditions Series MB/CA1 Body ported Series CJ2 Series CM2 Tube x Length T0604 x 1 m VQZ1151-01 Speed controller AS3001F-06 Silencer AN110-01 Tube x Length T0604 x 1 m T0806 x 1 m VQZ2151-02 Speed controller AS3001F-06 AS3001F-08 Silencer AN200-02 Tube x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m VQZ3151-03 Speed controller AS3001F
G36-2-01 G36-10-01-L G36-2-01-L G46-10-02 G46-2-02 G46-10-02-L G46-2-02-L Round type Pressure gauge Note 1) Attachments Round type (with color zone) Square Note 2) embedded type GC3-10AS [GC3P-010AS (Pressure gauge cover only)] GC3-2AS [GC3P-010AS (Pressure gauge cover only)] ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] Note 4) ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] Note 4)