SMC Corporation of America
Elite Part Number Search
Search Results "PSE303-MA"

Load current 5 to 40 mA 40 mA or less 80 mA or less Operating Precautions 1.5 V or less (0.8 V or less at 10 mA load current Internal voltage drop 4 V or less 0.8 V or less Do not use anything other than the mounting screws attached to the auto switch body to secure the switch.

How to order lead wire length (Example) L D-F9P Specifications Nil Lead wire length 0.5 m 3 m 5 m L Z CD-P11 CD-P12 24 VDC 50 mA 200 VAC 12.5 mA 100 VAC or less 25 mA Part no.

(Range) (Lwr_Lmt) (Upr_Lmt) -10..10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..5 V 5.25 to + 5.22 V 5.22 to +5.25 V -20..20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00 mA 4..20 mA +3.00 to +20.90 mA +3.10 to +21.00 mA -52No.EX-OMN0034

How to order lead wire length (Example) L D-F9P Specifications Nil Lead wire length 0.5 m 3 m 5 m L Z CD-P11 CD-P12 24 VDC 50 mA 200 VAC 12.5 mA 100 VAC or less 25 mA Part no.

or less 60 mA or less Weight 45 g Maximum load current: 80 mA Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V 2 outputs Resistance Output Note 6) specifications NPN open collector (PF2A300, PF2A310) Switch output Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (with load current of 80 mA) 2 outputs PNP open collector (PF2A301

Protection Short-circuit protection Input Output 0 to 10 V, 1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA 12 bit resolution Input signal range 10 to 10 V, 5 to 5 V 20 to 20 mA 16 bit resolution EX600-AXA 15 V 22 mA Note 2) Max. rated input signal 50 100 k Input impedance 0.05% F .S.

(Refer to the table below) Default setting Model (Output specification) OUT1 OUT2 A NPN NPN B PNP PNP C NPN Analogue 1 to 5 V D NPN Analogue 4 to 20 mA E PNP Analogue 1 to 5 V F PNP Analogue 4 to 20 mA L PNP L2 PNP PNP L3 PNP Analogue 1 to 5 V L4 PNP Analogue 4 to 20 mA -35No.PF-OMZ0002-A [F 0] Selection of reference condition, unit selection function, switch output specifications.

or less 50 mA or less Weight 45 g Maximum load current: 80 mA Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V 2 outputs Resistance Output Note 5) specifications NPN open collector (PF2W300, PF2W330) Switch output Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (with load current of 80 mA) 2 outputs PNP open collector (PF2W301

28 VDC or less 2.5 to 40 mA 40 mA or less Load current 4 V or less 0.8 V or less at 10 mA (2 V or less at 40 mA) Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating range .

ME MB RR RB MA MD MT E + Stroke A + (Stroke x 2) MC (RA) (mm) Bore size A E MA MB MC MD ME MT RA RB RR 90 12 16 20 25 32 40 33 RJ0806H M12 x 1.5 6 8 27 13 19 7 51 RJ0806H M12 x 1.5 6 33 28 16 19 8 7 58 94 RJ1007H M14 x 1.5 37 33 22 8 10 9 68 30 109 M14 x 1.5 37 RJ1007H 25 8 10 41 82 30 109.5 9 M20 x 1.5 RJ1412H 32 8 55 51 100 38 12 9 135.5 RJ1412H M20 x 1.5 8 55 60 32 38 12 9 108 142 -X -

40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Leakage current 100 A or less at 24 VDC 0.8 mA or less Indicator light Red LED lights up when turned ON.

28 VDC or less 24 VDC (10 to 28 VDC) Load voltage 40 mA or less 2.5 to 40 mA Load current 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating range .

Note 3) Under a 5 mA condition, the indicating light visibility becomes low and at a 2.5 mA condition, it may be unreadable. However, as long as the contact ouput is over a 1 mA condition, there will be no problem.

0.1 0.1 VY130-5 VY140-5 VY150-5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 V V V VY130-6 VY140-6 VY150-6 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V VY130-7 VY140-7 VY150-7 mA mA mA 4 0 8 12 16 20 4 0 8 12 16 20 4 0 8 12 16 20 2 2 2 VY130-8 0 5 10 15 20 VY140-8 0 5 10 15 20 VY150-8 0 5 10 15 20 3 3 3 mA mA mA Command signal Command signal Command signal VY1700/1701 VY1900/1901 Command

Note 4) At the atmospheric pressure, 1 VDC or 4 mA is output. 5 VDC or 20 mA is output at the rated pressure. Note 5) Please contact SMC regarding indication with other units of pressure. 0 25 50 75 100 Input signal (% F.S.)

mA (2 V or less at 40 mA) 4 V or less Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating position .

a CHM A MA a Cushion adjustment screw Air release R (max.)

28 VDC or less 40 mA or less 2.5 to 40 mA Load current 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating position .

1 V NPN(1 )(15 V) PFM7--CNPN(1 )(420 mA) PFM7--DDC(+) OUT1 DC(-) Max.28 V80 mA 1 V C15 V 1 k D420 mA 600 50 NPN(1 ) PFM7--GDC(+) OUT1 DC(-) Max.28 V80 mA 1 V ()30 ms -18No.PF-OMJ0005CN-I PNP(2 ) PFM7--BDC(+) OUT1 OUT2 DC(-) Max.80 mA 1.5 V PNP(1 )(15 V) PFM7--EPNP(1 )(420 mA) PFM7--FDC(+) OUT1 DC(-) Max.80 mA 1.5 V E15 V 1 k F420 mA 600 50 PNP(1 ) PFM7--HDC(+) OUT1 DC(-) Max