Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 NPN Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 NPN Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Please contact us for the latest version.sales@ocaire.com, IFW/PFW 1/4INCH NPT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 0.43108 lb
25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,
25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,