Magnet: -, Mounting: -, Cushion: -, Bore Size: -, Stroke A: -, +: -, Stroke B: -, Stroke Adjustment: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Stroke Options: -
Magnet: -, Mounting: -, Cushion: -, Bore Size: -, Stroke A: -, +: -, Stroke B: -, Stroke Adjustment: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Stroke Options: -
Magnet: None, Mounting: Double Clevis, Cushion: Rubber Bumper, Bore Size: 1", Stroke: 14", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Cushion: Rubber Bumper, Bore Size: 1", Stroke: 18", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Cushion: Rubber Bumper, Bore Size: 1", Stroke: 1/2", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Cushion: Rubber Bumper, Bore Size: 1", Stroke: 3 1/2", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Cushion: Rubber Bumper, Bore Size: 1", Stroke: 5 1/2", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Cushion: Rubber Bumper, Bore Size: 1", Stroke: 2 1/2", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Cushion: Rubber Bumper, Bore Size: 1", Stroke: 1", Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Magnet: None, Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 25 (1"), Stroke: 0800 (8")
Magnet: None, Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 25 (1"), Stroke: 0400 (4")
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The
Magnet: None, Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 25 (1"), Stroke: 0250 (2 1/2"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: None, Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 25 (1"), Stroke: 0300 (3")
Magnet: None, Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 25 (1"), Stroke: 1400 (14")
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.