SMC Corporation of America
Elite Part Number Search
Search Results "MXP8-20C-M9NZ"

Bore Size: 16mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers), Function: Standard, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: Z (5m)

Bore Size: 16mm, Stroke: 20mm, Adjuster: C (Metal Stopper), Magnet: Magnet and Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m)

Specification: Standard Type (Not Clean Room), Bore Size: 8 mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Metal Stopper Both Ends, Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -

Specification: Standard Type (Not Clean Room), Bore Size: 8 mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: C (Metal Stopper Both Ends), Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m)

Bore Size: 16mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 5m, Number: -

Bore Size: 10mm, Stroke: 20mm, Adjuster: Metal Stopper, Magnet: Magnet and Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -

Bore Size: 16mm, Stroke: 20mm, Adjuster: Metal Stopper, Magnet: Magnet and Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -

Bore Size: 10mm, Stroke: 20mm, Adjuster: C (Metal Stopper), Magnet: Magnet and Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m)

65 65 Vertical 145 175 175 Standby power consumption when operating [W] Note 10) Horizontal 2 2 2 Vertical 8 8 8 Electric specications Max. instantaneous power consumption [W] Note 11) 445 724 724 Type Note 12) Non-magnetizing lock Holding force lbf [N] 29 [131] 57 [255] 109 [485] 35 [157] 69 [308] 132 [588] 44 [197] 87 [385] 165 [736] Lock unit specications Power consumption [W] at 68F (20C

of 20%, V 1120 [W] x 1.2 = 1344 [W] After 15 minutes, cool 32C down to 20C.

20C (68F) bend the tubing into a U shape.

Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.

factor of 20%, 7.0 [kW] x 1.2 = 8.4 [kW] V After 15 minutes, cool 32C down to 20C.

O When the ambient temperature is 20C 5C and rated voltage is applied. P Coil change from AC to DC or DC to AC is impossible because the iron core shapes are different.

After 15 minutes, cool 32C down to 20C. HRL200-A Precautions on Cooling Capacity Calculation 1. Heating capacity When the circulating fluid temperature is set above room temperature, it needs to be heated by the thermo-chiller. The heating capacity depends on the circulating fluid temperature.

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) For details, please contact SMC.

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

A 10 () (+) White Black Conductor resistance /km, 20C Station 10 65 or less SOL. B 23 () (+) Gray Red 11 () (+) White Red SOL. A Withstand pressure V, 1 minute, AC Station 11 1000 SOL. B 24 () (+) Black White 12 () (+) Yellow Red SOL. A Insulation resistance M/km, 20C Station 12 5 or less SOL. B 25 () (+) White None Note) The minimum bending radius for D-sub connector cables is 20mm.