Bore Size: 8mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 6mm, Symmetric Type: Symmetric, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 25mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 12mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 12mm, Symmetric Type: Symmetric, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 10mm, Stroke: 20mm, Adjuster: Metal Stopper, Magnet: Magnet and Rail, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Type: L-Shaped Table Type, Cylinder Inner Diameter(Ø): 8, Stroke(mm): 20, Max. Load Mass (Horizontal Mounting)(kg): 1~4.9, Table Size Length L(mm): 55.5, Table Material: [Aluminum] Aluminum, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide 1 axis, Table Size Width W(mm): 32, Table Size Height H(mm): 23, Table Parallelism(µm): 30, Table Surface Treatment
Type: L-Shaped Table Type, Cylinder Inner Diameter(Ø): 8, Stroke(mm): 20, Max. Load Mass (Horizontal Mounting)(kg): 1~4.9, Table Size Length L(mm): 55.5, Table Material: [Aluminum] Aluminum, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide 1 axis, Table Size Width W(mm): 32, Table Size Height H(mm): 23, Table Parallelism(µm): 30, Table Surface Treatment
Note 2) Safety allowance x3 at 20C Note 3) To calculate flow factor for longer lengths of tube divide factor for 1 metre by actual length in meters.
MPa Proof pressure (20C) 20 to 80C Ambient and fluid temperature JIS B 0203 (Taper threads for piping) Thread Note 1) Refer to Particulate Generation Grade Classifications.
Features 1 New New 5 port solenoid valve series SY9000 Cv 2.8 (base mounted type with sub-plate) Interface regulator series ARBY3000/5000 (for series SY3000/5000) High speed response: 10ms (SY3000 single solenoid, 0.5MPa, 20C) (representative value) The innovative design of the pilot valve makes it possible to achieve a short response time of 10ms while consuming only a half watt of power
Standard Specifications/Single Unit (Standard Dew Point 20C) Membrane Air Dryer Series IDG Model Standard dew point: 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters. -20C low dew point just by installing in air pressure line.
The value of the minimum bending radius is measured at the temperature of 20C as shown below. KP LQ MQR Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. T T Fixed end IDK 3.
Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter change rate of 10% or less.
(mm) 7.3 5.8 4.4 2.8 8.8 Black (B) White (W) Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Blue (BU) Fixed end Translucent (N) Fluid Air 20C 0.8 Max.
Characteristics 65 or less Cable length (L) 9 stations{ Conductor resistance /km, 20C 10 stations{ 11 stations{ 1.5 m AXT100-DS25-015 Cable 25 core x 24AWG 3 m AXT100-DS25-030 Voltage limit V, 1 min, AC SOL.A SOL.B 1000 5 m AXT100-DS25-050 12 stations{ SOL.B COM. Connector terminal no.
MPa) Outlet air set temperature Outlet air set temperature 68F (20C) 77F (25C) Air flow Air flow 10.6 scfm (300 L/min [ANR]) 17.7 scfm (500 L/min [ANR]) E E IDH4 or IDH6 are selected from Data .
Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter rate of change of 10% or less.