Low concentrations, however, can lead to freezing when circulating fluid temperature is 10C or lower and cause the thermo-chiller to break down. 5. A magnet pump or mechanical seal pump is used as the circulating pump for the circulating fluid.

Trace the arrow mark , starting with the point A at the pressure dew point 10C to find the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark , starting with the point B to find the intersection C at the atmospheric pressure dew point. 3.

Trace the arrow mark , starting from point A at a pressure dew point of 10C to obtain the intersection B on the pressure characteristic line for 0.7 MPa. Trace the arrow mark , starting from point B to obtain the intersection C at the dew point under atmospheric pressure.

L SPECIFICATIONS Fluid Air S T D S T R O K E/H U N D R E D T H S O F A N I N C H Proof Pressure 1MPa / 145 PSI 6 (1/4) 050, 100, 150, 200 10 (3/8) 050. 100. 150, 200, 300, 400, 500, 600 16 (5/8) 050, 100, 150, 200, 300, 400, 500, 600, 700, 800 MaxImum Operating Pressure 0.7MPa / 100 PSI 6 0.1MPa / 17 PSI Minimum Operating Pressure 10, 16 0.05MPa / 8.5 PSI Ambient and Fluid Temperature -10C

Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 50F (10C) or less. Note 2) Use fluid in condition below as the circulating fluid.

Fluid and fluid temperature Air: 10 to 60C (Dew point temperature: 10C or less) Withstand pressure 2.0 MPa Max. system pressure 1.0 MPa Ambient temperature 20 to 60C Valve leakage*1/External leakage*1 Air 1 cm3/min (ANR) or less Mounting orientation Unrestricted Enclosure*2 IP67 (IP65 for the DIN terminal) Standards*3 CE/UKCA Operating environment Location without the presence of corrosive

) Facility water: 50F (10C) 0 0 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) HED007 60 80 100 120 140 F 40 2800 2400 Facility water: 95F (35C) Heating capacity (W) Facility water: 77F (25C) 2000 1600 1200 Facility water: 50F (10C) 800 400 0 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) 178 Chemical Thermo-con

(including four M10 bolts)9 Accessories Weight (dry state) kg Approx. 124 1 Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less.

(including 4 M10 bolts) Note 10) Weight (dry state) kg Approx. 130 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less. Note 2) Use fluid in condition below as the circulating fluid.

Refrigerant AFF AM UL certified product Improved corrosion resistance with the use of stainless steel, plate type heat exchanger (IDFB4E to 75E) AMD Power supply voltage: Single-phase 115 VAC (60 Hz) 230 VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(10C

Condition Condition Inlet air temperature 40C Inlet air temperature 55C Outlet air pressure dew point 10C Outlet air pressure dew point 10C Ambient temperature 35C Ambient temperature 35C Inlet air pressure 0.5MPa Inlet air pressure 0.7MPa Air flow 1200 l/min (ANR) Air flow 350 l/min (ANR) Power supply frequency 60Hz Power supply frequency 50Hz A = 0.85 based on conditions , and B-1 = 0.95

At the same ozone concentration of 1.1ppm, approximately 25% of the ozone still remains in the circuit as measured at point downstream of the mist separator (AM) at an atmospheric dew point of 10C. When the atmospheric dew point is 17C, approximately 45% of the ozone still remains.

to 70C With auto switch : 10C to 60C CB Air cushion Cushion CV/MVG to 250 : +1.0, 251 to 1000 : +1.4, 1001 to 1500 : +1.8 0 0 0 Allowable stroke tolerance CXW Basic, Axial foot, Front flange, Center trunnion Mounting bracket CXS * Load is limited by piston speed, mounting direction, operating pressure at locking.

. * Air purification rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more Bernoulli type XT661 X321 4C Outer body diameter: 4C 39 mm 6C 59 mm 8C 79 mm 10C 99 mm 4C 6C 8C 10C 120E 150E Bernoulli type Outer body diameter (mm) 39 59 79 99 l120 l150 Piping port size M5 x 0.8 Rc 1/8 XT661 X322 120E Fluid Air* Operating pressure 0.01 to 0.4 MPa Body size: l Proof pressure 0.6 MPa Ambient

30 30 30 30 30 Symbol: A21 Symbol: A22 Symbol: A23 Symbol: A24 Symbol: A25 30 30 30 Symbol: A29 Symbol: A28 Symbol: A26 Symbol: A30 Symbol: A27 30 30 30 30 30 20 Series MB1 Special port locations XC3 Heat resistant cylinder (to 150C) XB6 2 5 The cylinder seals are changed to a heat resistant (to 150C) material, for use under severe conditions which exceed the standard specifications of 10C

to 70C (without freezing) With auto switch : -10C to 70C (without freezing) Cushion Double side air cushion to 250: +1.0, 251 to 1000: +1.4, 1001 to 1500: +1.8 0 0 0 Stroke length tolerance Bracket type Basic type, Axial foot type, Front flange type Note) Load limits exist depending upon piston speed when locked, mounting direction and operating pressure.

property value Conventional unit system Density [kg/l] Specific heat C [kcal/(kgfC)] Specific heat C [kJ/(kgK)] Weight: volume ratio [kgf/l] Temperature 1.02 1.02 0.93 3.91 5C 1.02 1.02 0.93 3.91 10C 1.02 1.02 0.93 3.91 15C 1.01 1.01 0.93 3.91 20C 1.01 1.01 0.93 3.91 25C 1.01 1.01 0.94 3.91 30C 1.01 1.01 0.94 3.92 35C The above shown are reference values.

Fluid temperature (C) Solenoid valve option symbol Ambient temperature (C) 10 Note) to 60 V, M 10 Note) to 60 20 to 60 Nil, G Passage symbol 2 Note) Dew point temperature: 10C or less 1 Valve Leakage Internal Leakage Seal material Leakage Normally Closed (N.C.)

Note) Dew point temperature: 10C or less 4 Direct Operated 3 Port Solenoid Valve Series VX31/32/33 For Air / Single Unit How to Order (Single Unit) For Air Specifications For Water For Oil For Steam For Vacuum Pad Construction Dimensions 1 G G 5 1 VX DC 1 4 31 01 VX 1 4 31 01 R1 AC/Class B coil (Built-in full-wave rectifier type) Model Refer to Table (1) shown below for availability.

Low temperature operation 1) The valve can be used in an ambient temperature of between 4 to 14F (20 to 10C).