Bore size 12 12 mm 16 16 mm 20 20 mm 25 25 mm 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm Cylinder stroke [mm] Refer to Standard Strokes on page 3. Port thread type Nil M thread 12 to 40 Rc 50 to 100 TN NPT TF G Applicable Auto Switches/Refer to the WEB catalog or Best Pneumatics for further information on auto switches.
Guide Table Series MGF 40, 63, 100 How to Order Port thread type Rc NPT G Nil TN TF MGF 63 30 M9BW Made to Order Refer to page 413 for details. Guide Table Bore size/ Standard stroke (mm) Number of auto switches 40 63 100 30, 50, 75, 100 30, 50, 75, 100 30, 50, 75, 100 2 pcs. 1 pc. "n" pcs.
Thread type Opening/Closing stroke (mm) Cylinder bore Symbol Type 10 20 40 60 16 30 60 80 20 40 80 100 25 50 100 120 32 70 120 160 40 100 160 200 Symbol Nil 10 to 25 M thread Rc NPT G Nil 1 2 TN TF 32 to 40 Double acting Action D Applicable Auto Switch/Refer to pages 761 to 809 for further information on the auto switches.
V Relay, PLC 24 V 12 V 2-wire IC circuit 100 V or less -X Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 1665 for details.
Also, when exceeding the air cushion stroke ranges on page 1191, the piston speed should be 100 to 200 mm/s. Note 2) The piston speed is 100 to 1000 mm/s for centralized piping. Note 3) Use at a speed within the absorption capacity range. Refer to page 1191.
The following graphs show the displacement at point A, which is 100 mm apart from the center of rotation, where the load is applied.
L L H Holding point Holding point H MHF2-12D MHF2-8D 80 50 Pressure 0.2MPa 40 60 0.5MPa 0.5MPa Pressure 0.2MPa 0.6MPa 0.6MPa Overhang Hmm Overhang Hmm 0.7MPa 30 0.7MPa 0.3MPa 0.3MPa 40 0.4MPa 0.4MPa 20 20 10 0 0 40 20 50 30 10 80 60 40 20 Gripping point L mm Gripping point L mm MHF2-16D MHF2-20D 100 0.5MPa 100 Pressure 0.2MPa Pressure 0.2MPa 80 0.5MPa 0.6MPa 80 0.6MPa Overhang Hmm Overhang
Piston Speed 40 Without stroke adjusting unit 16 25 Bore size (mm) Note 1) 100 to 1000 mm/s L unit and H unit Stroke adjusting unit 100 to 1500 mm/s Note 1) When exceeding the air cushion stroke ranges on page 1094, the piston speed should be 100 to 200 mm/s. Note 2) Use at a piston speed within the absorption capacity range. Refer to page 1094.
V 100 V or less 100 V, 200 V 200 V or less 24 V or less IC circuit Grommet Relay, PLC 12 V Connector 2-wire 24 V IC circuit PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state
V Grommet IC circuit 100 V or less None B54 B64 (B54) (B64) 100 V, 200 V Yes Relay, PLC 12 V 2-wire 24 V 200 V or less None C73C C80C Yes Connector 24 V or less IC circuit None Diagnostic indication (2-color indication) (B59W) B59W Grommet Yes Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example)
V IC circuit Relay, PLC 2-wire 12 V 24 V 100 V or less Solid state auto switches marked with are produced upon receipt of order.
For details, refer to the next page. i Made to order 16 10, 20, 30, 40, 50, 75, 100, 125 Port Switch mounting groove Port Switch mounting groove 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Because piping ports and auto switch grooves are provided on both sides, only the adjuster part of the centralized adjuster is symmetric.
Rotary Angle Port side During unclamping (Extension end) 80 to 100 (9010) L type (Counterclockwise) During unclamping (Extension end) 80 to 100 (9010) R type (Clockwise) Theoretical Output Operating pressure (MPa) Unit: N Bore size (mm) Rod size (mm) Operating direction Piston area (cm2) 0.8 1.1 1.5 2.0 2.0 3.1 3.8 4.9 6.0 8.0 10.6 12.6 16.5 19.6 28.0 31.2 1.0 85 113 151 201 201 314 378 491
V Relay, PLC 2-wire 12 V IC circuit No 100 V or less DNil M L Z (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 597 for details.
V 12 V 5 V, 12 V Grommet No Relay, PLC 100 V or less Yes 100 V, 200 V No 200 V or less 2-wire 24 V PLC Terminal conduit 12 V Relay, PLC Yes 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indication) Solid state auto switches marked with are produced upon receipt of order.
Grommet 24 V 2-wire No A96V A96 5 V IC circuit Yes 100 V A93V A90V A93 A90 IC circuit Relay, PLC 12 V 100 V or less Solid state auto switches marked are produced upon receipt of order. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to page 445 for applicable auto switches other than listed above.
V Relay, PLC 2-wire A90V IC circuit 100 V or less 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
200 10 400 12 10, 25, 40, 50, 80, 100, 125, 160, 200 16 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 1000 25 Refer to pages 101 to 111 for cylinders with auto switches.
Yes Grommet A90V No Yes No Yes No 100 V or less IC circuit Relay PLC 100 V, 200 V 200 V or less 12 V Connector 2-wire 24 V 24 V or less 100 V, 200 V IC circuit PLC Terminal conduit Yes Relay PLC DIN terminal Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance
Rotation angle 90 180 80 to 100 170 to 190 Applicable Auto Switches/Refer to pages 797 to 850 for detailed auto switch specification.