Symbol: 15R3 (2 Port, N.C., Port 1 IN, Port 2 OUT), Function: HY (High-pressure w/Power Saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: w/o Sub-plate, Lead Wire Length: 6 (600mm), CE Compliant: Q (CE Compliant)
Symbol: 15R3 (2 Port, N.C., Port 1 IN, Port 2 OUT), Function: HY (High-pressure w/Power Saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1U (1/4-28UNF, PVDF), Lead Wire Length: 6 (600mm), CE Compliant: Q (CE Compliant)
Symbol: 15R3 (2 Port, N.C., Port 1 IN, Port 2 OUT), Function: HY (High-pressure w/Power Saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: w/o Sub-plate, Lead Wire Length: 6 (600mm), CE Compliant: Q (CE Compliant)
Symbol: 15R3 (2 Port, N.C., Port 1 IN, Port 2 OUT), Function: HY (High-pressure w/Power Saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 6 (600mm), CE Compliant: Q (CE Compliant)
Symbol: 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: High-pressure w/Power Saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: w/o Sub-plate, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: High-pressure w/Power Saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: w/o Sub-plate, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: High-pressure w/Power Saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1/4-28UNF, PVDF, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: High-pressure w/Power Saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: w/o Sub-plate, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: High-pressure w/Power Saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Lead Wire Length: 600mm, CE Compliant: CE Compliant
MHZ2-6 and MHZJ2-6.
5 5/8 6 1/16 200 (2) 5/8 7/16-20 3/4 2.6 3/8 2 11/16 1 7/16 1 9/16 1/8 1 1/8 1 1/8 3/8 9/16 5/16-24 2.5 0.3 3/8 3/8 1.26 1.06 1 3/4 1 1.71 2.4 3 5/8 6 5 5/8 6 3/16 250 (2.5) 5/8 7/16-20 3/4 3.1 3/8 3 1/8 1 5/8 1 9/16 1/8 1 1/8 1 1/8 3/8 9/16 5/16-24 3 0 3/8 3/8 1.3 1.06 2 1/4 1 1.75 2.48 3 3/4 6 1/8 5 3/4 6 5/16 325 (3.25) 1 3/4-16 1 1/8 3.9 1/2 3 13/16 1 15/16 1.25 3/4 11/64 1.5 1.5 1/2
10 8 11.5 16 9 13.5 8 13.5 13 200 8 9 7 8.5 12 6.5 9.5 7 11.5 250 10 9 7 7.5 13.5 9.5 7 10.5 300 12 8 6 6.5 9.5 7.5 6 9.5 350 14 6 6 5 9.5 5.5.11 HART version Select if device is used as HART 6 or HART 7 device by using the + and keys.
18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25 29 1/8 83 124 25 to 300 22 19.5 17 50 18.5 10 36 5.5 6 18 12 40 6 33 M5 x 0.8 5.5 8 3.5 M10 x 1.25 29 1/8 83 129 32 to 300 22 19.5 17 50 20 12 38 6.6 6 18 12 40 6 38 M5 x 0.8 5.5 10 3.5 M10 x 1.25 35.5 1/8 85 131 40 to 500 30 27 19 60 26 16 46 6.6 6 19 13 50 8 47 M6 x 1.0 6 14 4 M14 x 1.5 44 1/8 93 149 50 to 600 109 35 32 27 75 32 20 58 9 9 21 14 58
K KA M MM NA PG PH PL S LC LD LS LH LT LX LZ X Y W XA XB 141 (149) 117 (125) 24 7 5 6 3 M8 x 1.25 1/8 21.5 2 65 4 6 25 3 50 62 15 10 3 12 151 (159) 127 (135) 29 7 5.5 8 3.5 M10 x 1.25 1/8 26.5 2.5 73 4 6 28 3 57 70 15 10 3 12 154 (162) 128 (136) 35.5 8 5.5 10 3.5 M10 x 1.25 1/8 26.5 2.5 73 4 6.6 28 3 60 74 16 10 3 12 169 (178) 142 (151) 44 8.5 6 14 4 M14 x 1.5 1/8 28 2.5 81 4 6.6 33 3 68
) (mm) Solid state auto switch D-M9 Size A 10 6 15 6 20 6 30 6 40 6 Operating Angle and Hysteresis Angle Solid state auto switch D-M9 Size Operating angle (m) Hysteresis angle Note) Since the figures in the table on the left are 10 36o 5o provided as a guideline only, they cannot be guaranteed.
25 MB MA HC HE KB KA LA LB LC PA PB PD PC ME MD MIS12-10 MC HD HA, HB JB JA N Model 48 38 28 39 29 19 MIS12-30 MIS12-20 13 10 7 6 4 3.5 17.5 11.6 2.3 M2.6 x 0.45 19 4 M4 x 0.7 6 11 5 2.5H9 0 +0.025 18 6 MIS20-30 MIS20-20 MIS20-10 7 40.5 30.5 20.5 52 42 32 8.5 17.5 4H9 0 +0.030 5 5 2.8 M3 x 0.5 26 6 M6 x 1 9 25 12 8 10 15 14 26 10 Series MIW/MIS Finger options Tapped on upper and lower faces
Top mounting (Body tapped) L4 L5 L6 Size Screw Max. screw-in Height Counterbore depth [mm] [mm] depth [mm] 10 M5 x 0.8 6 6 3.9 20 M6 x 1 6 8 4.5 30 M6 x 1 6 8 4.5 50 M8 x 1.25 8 8.5 5.6 -28- With interchangeable plate 4.
10, 15, 20 25, 32 40, 50, 63 CY1S, CY1L: 6 to 40 12, 16, 20 25, 32, 40 50, 63, 80 100 6, 10 15, 20 25, 32 12, 16, 20 25, 32, 40 50, 63, 80 100 10, 16 20 25, 32 12, 16 20, 25 32, 40 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 20, 25 32, 40 50, 63 12, 16 20, 25 6, 10 16 20, 25, 32 40, 50 10, 15 25 6, 10 16 20, 25 32, 45 Bore size (mm) 5 to 50mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50mm/s Piston speed
Model A B Same side Different sides 4 6.5 8 8 Different sides Same side D-C7, D-C8 31.5 29.5 31 31 n-2 2 15 + 45 ( ) (n = 2, 4, 6...) Approx. Hs D-C7, D-C8 30.5 35 40.5 40.5 50 + 45 (n-2) 15 50 A B 4 6.5 8 8 n-2 2 15 + 50 ( ) (n = 2, 4, 6...) D-C73C 31.5 29.5 31 31 D-C73C 15 65 65 + 50 (n-2) Approx. Hs 33 37.5 43 43 n-2 2 D-H7, D-H7W D-H7F 15 + 45 ( ) (n = 2, 4, 6...)
Operating environment .23 5-6. Lubrication .23 6. Maintenance or inspection .23 6-1. Maintenance or inspection .23 6-2. Replacement part .24 6-3. Maintenance .24 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.